GOODMAN//Ducted units
Goodman ducted heat pump: ENERGY STAR up to 24,000 BTU/h in single zone
Six single-zone ducted units in our store, from 12,000 to 60,000 BTU/h. With the E23 outdoor unit, the 12,000, 18,000 and 24,000 are ENERGY STAR cold-climate certified and listed on NEEP (AHRI 206900420 to 206900422). The 36,000, 48,000 and 60,000 are on neither list, and no GOODMAN document we read describes them.
The question this page answersDucted 12,000 to 60,000: which ones are ENERGY STAR cold climate, and how much heat do they deliver in deep cold?
The six GOODMAN ducted units in our store
Each product page opens a price request. A ducted unit serves several rooms: the size is set from the home's heating needs.
Tool//The 24,000 threshold
Size by size, what ENERGY STAR and NEEP list
Pick a size; the dashed sizes are on neither list. From 12,000 to 24,000 BTU/h, the tool gives the ENERGY STAR number, the NEEP record, the LogisVert line and the maximum heat NEEP lists at four temperatures. From 36,000 to 60,000, it says what is missing.
Ducted 24,000 BTU/h: on both lists
MSH243E23MCAA + MST243E21ADAA · AHRI 206900422
- ENERGY STAR number
- 3999964cold climate: yes
- NEEP record
- 514189read November 5, 2026
- Rated heating at -8.3 °C
- 21,000 BTU/hENERGY STAR list
- LogisVert
- $2,520indicative amount
Maximum heat listed on NEEP-30 °C, the record's last pointRated heat
At -30 °C, NEEP lists at most 11,000 BTU/h, at a COP of 1.24. Nothing is listed below that: backup heat is chosen on site.
For the 24,000, the maximum heat NEEP lists is higher at -15 °C (27,000 BTU/h) than at -8.3 °C (24,000 BTU/h). The record is shown as it is.
On both lists. Indicative LogisVert amount of $2,520, that is 21,000 BTU/h at -8.3 °C × $120 per 1,000 BTU/h (LogisVert guide v1.10, p. 15). Only Hydro-Québec confirms the assistance granted.
See the 24,000 BTU/h ducted unit product pageBars: maximum heat listed on NEEP for the system with the E23 outdoor unit, all on the same scale (30,400 BTU/h, the largest value in the tool); in red, -30 °C, the record's last point. Teal mark: rated heat at the same point; NEEP gives none at -30 °C. Indicative amount: AirGreen calculation under the rule in LogisVert guide v1.10; AirGreen's GOODMAN page quotes the same amounts from Hydro-Québec's list of October 7, 2026, which could not be read again. Off-list sizes: GOODMAN brochures read (sources 1 to 4) and Hydro-Québec's notice of September 25, 2025 (source 7).
ENERGY STAR and NEEP//12,000 to 24,000
The three listed ducted units, line by line
Each column is one system: the MSH…E23MCAA outdoor unit and the MST…E21ADAA indoor unit of the same size. The last two lines come from GOODMAN documents.
| Value | 12,000 | 18,000 | 24,000 |
|---|---|---|---|
| System | MSH123E23MCAA + MST123E21ADAA | MSH183E23MCAA + MST183E21ADAA | MSH243E23MCAA + MST243E21ADAA |
| AHRI certificate | 206900420 | 206900421 | 206900422 |
| ENERGY STAR number (source 5) | 3999962 | 3999963 | 3999964 |
| Cold-climate designation, certification date | yes, April 17, 2026 | yes, April 17, 2026 | yes, April 17, 2026 |
| SEER2 | 19.5 | 18.0 | 19.2 |
| HSPF2, region IV | 10.0 | 9.5 | 10.5 |
| Rated heating at -8.3 °C (17 °F) | 10,600 BTU/h | 15,000 BTU/h | 21,000 BTU/h |
| Heating at -15 °C (5 °F) | 12,100 BTU/h | 17,700 BTU/h | 27,000 BTU/h |
| NEEP record (source 6) | 514191 | 514190 | 514189 |
| Heating at 8.3 °C (47 °F), minimum and maximum | 3,200 to 16,300 BTU/h | 7,000 to 22,000 BTU/h | 7,500 to 30,400 BTU/h |
| HSPF2, region V | 8.2 | 7.5 | 8.8 |
| LogisVert, indicative amount | $1,272 | $1,800 | $2,520 |
| Indoor unit, W × D × H (in) | 27.56 × 17.72 × 7.87 | 34.65 × 28.53 × 8.27 | 43 × 30 × 10 |
| Airflow high / medium / low | 353 / 283 / 177 cfm | 530 / 450 / 371 cfm | 776 / 694 / 435 cfm |
Indicative amount: ENERGY STAR capacity at -8.3 °C × $120 per 1,000 BTU/h, the rule in LogisVert guide v1.10 (source 8, p. 15). Hydro-Québec's list of October 7, 2026, quoted on AirGreen's GOODMAN page, gave the same amounts; the current list could not be read again (source 9). Only Hydro-Québec confirms the assistance granted. Dimensions: 2018 document and 2024 brochure, which agree; the 2021 brochure rounds. The 2024 brochure (source 4, p. 6) pairs these indoor units with the MSH…G22MCAA outdoor unit, pairs ENERGY STAR lists with the same values (3436384 to 3436386); its 17 °F line gives the 5 °F value for the 12,000. We keep the lists.
Cold climate//Down to -30 °C
What makes a ducted unit "cold climate", and what is left at -30 °C
The ENERGY STAR criterion, then what the NEEP records give at their coldest point and how often Montreal gets that cold.
The ENERGY STAR criterion
For the cold-climate designation, ENERGY STAR asks for a COP of at least 1.75 at -15 °C (5 °F) and, at that same point, at least 70% of the capacity at 8.3 °C (47 °F) (source 10).
At -15 °C, the NEEP records of the three ducted units (AHRI 206900420, 206900421 and 206900422) give a COP of 1.96, 1.85 and 2.00. Their rated heat there is 97%, 93% and 108% of their rated heat at 8.3 °C (AirGreen calculation on the NEEP records); the 24,000 goes over 100% because NEEP lists 27,000 BTU/h at -15 °C against 25,000 at 8.3 °C.
At -30 °C, the last point on the record
Between -15 °C and -30 °C, the maximum heat listed on NEEP drops by 49 to 59% (AirGreen calculation). At -30 °C (-22 °F), NEEP lists at most 5,500, 9,000 and 11,000 BTU/h for the 12,000, the 18,000 and the 24,000, at a COP of 1.07, 1.50 and 1.24 (source 6, AHRI 206900420 to 206900422). Below that, NEEP lists nothing, and GOODMAN publishes nothing for these systems in the documents read.
At Montréal-Trudeau, the daily minimum drops below -30 °C on 0.21 days a year on average (1991-2020 normals, code C: at least 20 years of data; source 11). It is rare, but output drops well before that: we choose the backup heat along with the size.
Compare//Same capacity
Ducted or cassette, at 18,000 BTU/h
Same outdoor unit, MSH183E23MCAA, two indoor units. The ducted unit keeps more heat at -15 °C; the cassette has the better SEER2.
| At 18,000 BTU/h | Ducted 18,000 | Cassette 18,000 |
|---|---|---|
| Rated heating at -8.3 °C (ENERGY STAR) | 15,000 BTU/h | 15,600 BTU/h |
| Heating at -15 °C (ENERGY STAR) | 17,700 BTU/h | 16,000 BTU/h |
| Maximum heating at -30 °C (NEEP) | 9,000 BTU/h | 8,800 BTU/h |
| COP at maximum, -30 °C (NEEP) | 1.50 | 1.27 |
| SEER2 (ENERGY STAR) | 18.0 | 20.0 |
| HSPF2, region IV (ENERGY STAR) | 9.5 | 9.5 |
| HSPF2, region V (NEEP) | 7.5 | 7.8 |
| Airflow, high speed (GOODMAN) | 530 cfm | 560 cfm |
| LogisVert, indicative amount | $1,800 | $1,872 |
Lists: sources 5 and 6, NEEP records 514190 (AHRI 206900421) and 514186 (AHRI 206900426); airflow: source 1, p. 6. LogisVert: indicative amount, AirGreen calculation under guide v1.10 (source 8, p. 15). Only Hydro-Québec confirms the assistance granted. See the Cassettes page.
Did you know//GOODMAN documents and lists
A wired control and two listings that changed
A wired wall control
For the ducted unit, GOODMAN calls for a wired control on the wall: "wall thermostat" in the 2021 brochure, a wired control panel in the 2018 French-language document. The wall unit and the cassette come with a remote instead.
Source 1, p. 6; source 3, p. 9In 2021, the 24,000 had no NEEP mark
The 06-21 revision marks the ducted unit "NEEP-12K & 18K", then with the E21 outdoor unit. Today, NEEP also lists the 24,000, with the E23 outdoor unit (record 514189, AHRI 206900422).
Source 2, p. 6; source 6In 2018, a ducted head on multi-zone was not ENERGY STAR
GOODMAN's 2018 French-language document accepts the ducted unit on its three multi-zone outdoor units, but a footnote says that using it there is not ENERGY STAR certified. The ENERGY STAR list read on November 5, 2026 does list all-ducted GOODMAN multi-zone systems, from the MST…G22MHAA series, which our store does not sell.
Source 3, p. 11; source 4, p. 10; source 5AirGreen × GOODMAN//Who brings what
From the air ducts to the unit: GOODMAN's part, AirGreen's part
What GOODMAN brings
- Three documented sizes, 12,000, 18,000 and 24,000 BTU/h
- The ENERGY STAR cold-climate designation for those three sizes, with the MSH…E23MCAA outdoor unit
- Indoor units 7.87 to 10 in tall, from the 12,000 to the 24,000
- Three fan speeds, up to 776 cfm on the 24,000
What AirGreen brings
- Where the indoor unit goes and how the air ducts reach each room
- Installation by our refrigeration technicians, under AirGreen's RBQ licence 5645-9605-01
- The choice of backup heat
- An on-site assessment of heating needs before the size is set
Questions//Ducted units
Questions about the ducted heat pump
Of the ducted units in our store, which qualify for Hydro-Québec's LogisVert financial assistance?
Under the rules in LogisVert guide v1.10, three of the six: the 12,000, the 18,000 and the 24,000, with the E23 outdoor unit, which are ENERGY STAR cold-climate certified. The indicative amounts are $1,272, $1,800 and $2,520. Hydro-Québec's list of October 7, 2026 gave the same amounts; the current list could not be read again. Only Hydro-Québec confirms the assistance granted.
Why are there no figures for the 36,000, 48,000 and 60,000?
None of the four GOODMAN brochures we read names the MST363E18ADAA, MST483E18ADAA and MST603E18ADAA indoor units, or their MSH…E18MCAA outdoor units. NEEP returned nothing for their AHRI numbers, 203991096, 203991097 and 206199280, and the ENERGY STAR list holds no E18 system. With no document read, we give no figures for these sizes; the price comes with the quote.
What floor area does GOODMAN give for each ducted unit?
An indicative range, printed in its 2018 French-language document: 161 to 237 sq ft for the 12,000, 248 to 355 sq ft for the 18,000 and 312 to 463 sq ft for the 24,000. A ducted unit splits its air between several rooms through the air ducts: duct length, insulation and each room's windows weigh on the choice, which is why heating needs are assessed on site.
Are NEEP and ENERGY STAR the same thing?
No. ENERGY STAR certifies a system and gives it a number. NEEP keeps a list of cold-climate heat pumps, with their output at several temperatures. For LogisVert, only ENERGY STAR certification has counted since November 26, 2025: Hydro-Québec told its partners so on September 25, 2025.
Why is the heat at -15 °C higher than at -8.3 °C?
For rated heat, it is the case for all three sizes on the ENERGY STAR list: 12,100 against 10,600, 17,700 against 15,000 and 27,000 against 21,000 BTU/h. At -15 °C, the NEEP records (AHRI 206900420 to 206900422) list a single value, both rated and maximum. No GOODMAN document we read explains it.
Read next//The GOODMAN space
In the ceiling, central or multi-zone
A ducted unit in your home: we start from the air ducts
We find where the indoor unit can go, trace the air ducts to each room and plan backup heat for the days when the house asks for more than the ducted unit gives.
Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.
An AirGreen technician assesses the heating and cooling needs, where the units will go and the refrigerant line route on site before proposing a model.
Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.
The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.
Sources
- GOODMAN, "Heat Pump and Air Conditioner Ductless Units", 19 Series and 21 Series, code CB-DL-1921S-HP 03-21, p. 6 and 7. GOODMAN document kept in AirGreen's files.
- GOODMAN, same brochure, revision CB-DL-1921S-HP 06-21, p. 6.
- GOODMAN, "Thermopompe et climatiseur simple et multizones" (French-language document), code CB-GDuctless2018-FR 10.18, p. 9 to 11.
- GOODMAN, 2024 ductless brochure, code CB-DL-1921S-HP 05-24, p. 6 and 10; it pairs the indoor units with MSH…G22MCAA outdoor units.
- ENERGY STAR, certified heat pumps (dataset w7cv-9xjt), Canadian market, read November 5, 2026: systems 3999962, 3999963 and 3999964, cold-climate designation; pairs with the MSH…G22MCAA outdoor unit 3436384 to 3436386; MST…G22MHAA multi-zone systems; no E18 system. energystar.gov
- NEEP, cold-climate air-source heat pump list, records 514191 (AHRI 206900420), 514190 (AHRI 206900421) and 514189 (AHRI 206900422), read November 5, 2026; no result for AHRI numbers 203991096, 203991097 and 206199280. ashp.neep.org
- Hydro-Québec, "LogisVert Efficient Homes Program – ENERGY STAR Heat Pump", partner notice of September 25, 2025: ENERGY STAR units only from November 26, 2025; NEEP data no longer used. hydroquebec.com
- Hydro-Québec, LogisVert participation guide, residential customers (French), version 1.10 of September 15, 2026, p. 15: $120 per 1,000 BTU/h at -8 °C for an ENERGY STAR cold-climate heat pump. hydroquebec.com
- Hydro-Québec, list of eligible heat pumps of October 7, 2026, as quoted on AirGreen's GOODMAN page. The current list could not be read again on November 5, 2026.
- ENERGY STAR, "Heat Pump Equipment Key Product Criteria", cold-climate criteria (COP at 5 °F and capacity at 5 °F against 47 °F), undated page, read November 5, 2026. energystar.gov
- Environment and Climate Change Canada, Canadian Climate Normals 1991-2020, MONTREAL TRUDEAU (AIRPORT), days with a minimum below -30 °C (code C: at least 20 years of data), page modified October 22, 2026. climate.weather.gc.ca
Read and dated by AirGreen. Dimensions and airflow: GOODMAN documents; performance: the ENERGY STAR and NEEP lists. A real installation can give other values.