AirGreenGOODMAN
GOODMAN · Series 19 · Series 21 · GLZS4B · GLZS4MThe GOODMAN space at AirGreenSold and installed by AirGreen. Montreal, Laval, Longueuil, the South Shore and the North Shore.
All of GOODMAN

GOODMAN//Wall air conditioners

Goodman wall air conditioners: which circuit, and how much cooling

Five Series 19 wall air conditioners, from 9,000 to 24,000 BTU/h, with no heating. Only one runs on 115 V: the 12,000 MSC121E19. The other four need a 208-230 V circuit. The tool matches your circuit to the right model, with the cooling and the amps GOODMAN publishes.

The question this page answers115 V or 208-230 V: which Goodman 19 fits my circuit, and how much does it really cool?

115 Vone model only: the 12,000 MSC121E19Source 1, p. 4
10.43 Arated current of the MSC121E19 in coolingSource 1, p. 4
-15 to 50 °Cpublished outdoor cooling rangeSource 1, p. 4
20SEER of the 18,000, above the "up to 19 SEER" that heads GOODMAN's tableSource 1, p. 4

The five GOODMAN air conditioners we sell

Four on 208-230 V, one on 115 V, all on R-410A. Each product page opens a quote request.

5 models in our store

Tool//My circuit

My circuit: the right model, its amps and its cooling

Pick your circuit, then the size. On 115 V, only the 12,000 exists: the other sizes grey out. The bars compare the current of all five models.

My circuit, GOODMAN wall air conditionersSource 1, p. 4
Circuit
Size (BTU/h)

12,000 BTU/h air conditioner on 208-230 V

MSC123E19MCAA + MSC123E19AXAA

Rated cooling
11,500 BTU/h500 BTU/h below the 12,000 in its name
Input power
1,037 Win cooling
Rated current
4.5 Ain cooling
Minimum circuit ampacity
11 A
Maximum fuse
15 A

Rated current of the five models, in cooling

9,0003.53 A
12,000 · 115 V10.43 A
12,0004.5 A
18,0006.7 A
24,0009.0 A

208-230 V single-phase circuit. The minimum circuit ampacity and the maximum fuse above set that circuit. 115 V exists only at 12,000.

See the MSC123E19 product page

Values at the cooling rating point, 03-21 brochure; the 06-21 revision prints the same ones. Minimum circuit ampacity and maximum fuse are the circuit values GOODMAN gives.

GOODMAN//Specifications

The five air conditioners, side by side

Values from the 03-21 brochure (source 1, p. 4); the 06-21 revision prints the same ones unless noted (source 2, p. 4).

Goodman Series 19, single-zone wall air conditioner
Published value9,00012,000, 115 V12,00018,00024,000
Outdoor unitMSC093E19MCAAMSC121E19MCAAMSC123E19MCAAMSC183E19MCAAMSC243E19MCAA
Power supply208-230 V115 V208-230 V208-230 V208-230 V
SEER1916.5192019
Indoor sound high / medium / low, dB(A)38 / 32 / 26.538.5 / 33 / 24.537.5 / 34.5 / 24.542 / 34.5 / 30.546 / 40.5 / 34.0
Outdoor sound, dB(A)51.051.551.553.557.0
Indoor unit W × D × H, in28.4 × 7.36 × 11.4231.6 × 7.5 × 11.731.6 × 7.5 × 11.738 × 8.5 × 12.642.5 × 8.9 × 13.2
Refrigerant lines liquid / gas, in1/4 / 3/81/4 / 1/21/4 / 1/21/4 / 1/23/8 / 5/8
Maximum line length / maximum lift, ft82 / 3382 / 3382 / 3398 / 6698 / 66
Precharge, ft2020202030

Highlighted: what sets one model apart from the other four. Height of the 9,000 head: 11.3 in in the 03-21 brochure, 11.42 in in the 06-21 revision; we use the revision. SEER of the 18,000: 20, while GOODMAN's table is headed "up to 19 SEER"; we quote both. GOODMAN does not say where sound is measured.

GOODMAN//Published cooling

How much cooling, really

An air conditioner's name gives its size; the brochure gives its rated cooling (source 1, p. 4). The two do not always match.

Size in the name and published rated cooling
ModelSize in the name, BTU/hRated cooling, BTU/hDifference, BTU/h (AirGreen calculation)
MSC093E199,0009,0000
MSC121E19, 115 V12,00012,0000
MSC123E1912,00011,500-500
MSC183E1918,00017,000-1,000
MSC243E1924,00022,000-2,000

Highlighted: the three models out of five for which GOODMAN publishes a rated cooling below the size in the name. That rated figure is what we compare with the room's needs, not the name.

Compare//Same nominal size

Air conditioner or Series 19 heat pump, at 12,000 BTU/h

Same series, same size in the name. The air conditioner needs a lower minimum circuit ampacity; the heat pump adds heating.

GOODMAN data, source 1, p. 4 and 5

Air conditionerMSC123E19MCAA + MSC123E19AXAA
Series 19 heat pumpMSH123E19MCAA + MSH123E19AXAA
At 12,000 BTU/hAir conditionerSeries 19 heat pump
Rated cooling11,500 BTU/h12,000 BTU/h
Cooling input power1,037 W1,065 W
Cooling rated current4.5 A4.5 A
Minimum circuit ampacity / maximum fuse11 / 15 A15 / 15 A
SEER1919.0
R-410A charge18.7 oz29.6 oz
Rated heating at 8.3 °Cnone12,000 BTU/h

For the heat pump's five sizes, see the Series 19 page.

Did you know//GOODMAN documents

Three air conditioner details from GOODMAN's brochure

01

The 115 V model gives less cooling per watt

GOODMAN publishes an EER of 10.0 for the 12,000 on 115 V, against 11.0 for the 12,000 on 208-230 V, or 11.1 in the 06-21 revision.

Source 1, p. 4; source 2, p. 4
02

The narrowest wall head in the brochure: 28.4 in

The 9,000 MSC093E19 has a 28.4 in wide head. Every other wall head in the 2021 brochure, air conditioners and Series 19 and 21 heat pumps alike, is at least 31.6 in wide.

Source 1, p. 4 to 6
03

From 12,000 to 18,000, more than twice the air

At high speed, GOODMAN publishes 242 cfm for the head of the 12,000 on 208-230 V and 530 cfm for the 18,000's. The 06-21 revision prints 241 and 529.

Source 1, p. 4; source 2, p. 4

AirGreen × GOODMAN//Who brings what

What each one brings to your air conditioner

GOODMANWhat GOODMAN brings

  • Five wall air conditioners, from 9,000 to 24,000 BTU/h, on R-410A
  • A 12,000 on 115 V, the other four on 208-230 V single phase
  • A rated cooling published for each model, sometimes below the size in its name
  • The minimum circuit ampacity and maximum fuse of each model

Questions//Wall air conditioners

Questions about GOODMAN wall air conditioners

Does the 115 V model plug into an outlet?

GOODMAN mentions no plug. It gives a 115 V power supply, a minimum circuit ampacity of 15 A and a maximum fuse of 20 A: those are circuit values. We look at what your panel allows during the visit.

208 V or 230 V: do I have to choose?

No. GOODMAN publishes a single power supply, 208-230 V single phase, for the 9,000, the 12,000, the 18,000 and the 24,000.

Can a wall air conditioner heat in winter?

No. The MSC…E19 units are air conditioners: GOODMAN publishes no heating value for them. To heat with a wall head, you need a wall heat pump.

Can I add a second room later?

Not on the same outdoor unit: a second room needs a second system. These air conditioners are single zone, one head per outdoor unit. In the same brochure, GOODMAN's multi-zone outdoor units are Series 21 heat pumps, like those in our 2-zone systems.

Minimum circuit ampacity and maximum fuse: what are those two figures for?

The minimum circuit ampacity sets the smallest wire size that can feed the unit; the maximum fuse is the largest protection allowed on that circuit. GOODMAN publishes both for each model.

Read next//The GOODMAN space

Related pages

AirGreen

A GOODMAN air conditioner in your home: we start with the panel

We open the electrical panel first, then look at the room and the wall for the outdoor unit. The panel decides between 115 V and 208-230 V; the room decides the size.

Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.

Free on-site estimate

An AirGreen technician assesses the room's cooling needs, your electrical panel, where the units will go and the refrigerant line route on site before proposing a model.

RBQ licence 5645-9605-01

Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.

The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.

Sources

  1. GOODMAN, "Heat Pump and Air Conditioner Ductless Units", 19 Series and 21 Series, code CB-DL-1921S-HP 03-21, p. 4 to 6. GOODMAN document kept in AirGreen's files.
  2. GOODMAN, same brochure, revision CB-DL-1921S-HP 06-21, p. 4.

Read and dated by AirGreen. Capacities and limits are the ones GOODMAN publishes; a real installation can give other values.