GOODMAN · Series 19 · Series 21 · GLZS4B · GLZS4MThe GOODMAN space at AirGreenSold and installed by AirGreen. Montreal, Laval, Longueuil, the South Shore and the North Shore.
All of GOODMAN

GOODMAN//Wall units//Series 19

Goodman Series 19 wall heat pump: five sizes, from 12,000 to 36,000 BTU/h

The only series that goes past 24,000 BTU/h among the GOODMAN wall units AirGreen sells. From one size to the next, the SEER, the outdoor sound, the line length and the fuse change, and not always the way you would expect. The ladder below lines them up, size against size.

The question this page answersWhich Goodman 19, from 12,000 to 36,000 BTU/h, and what changes from one size to the next?

213 ftof refrigerant line allowed on the 36,000Source 1, p. 5
55.0 dB(A)outdoor unit of the 12,000, the quietest of the fiveSource 1, p. 5
3.43COP at 8.3 °C of the 12,000, the highest in the seriesSource 1, p. 5
35 Amaximum fuse of the 36,000Source 1, p. 5

The five Goodman 19 units we sell

From 12,000 to 36,000 BTU/h, each with its own product page and quote request.

5 models in our store

Tool//The 19 ladder

The 19 ladder: one size, and what changes at the next

Pick a size. The table gives what GOODMAN publishes for it and for the size above; highlighted cells are the ones that change.

The 19 ladder, Goodman Series 19Sources 1 and 2, p. 5
Size (BTU/h)

Goodman 19, 12,000 BTU/h

MSH123E19MCAA + MSH123E19AXAA

Values GOODMAN publishes for this size and the next
Published value12,00018,000next size
SEER19.019.0
HSPF region IV9.510.0
HSPF region V8.08.0
COP at 8.3 °C3.433.10
Outdoor unit sound55.0 dB(A)57.5 dB(A)
Outdoor unit, W × D × H31.5 × 13.1 × 21.8 in31.5 × 13.1 × 21.8 in
Maximum line length82 ft98 ft
Maximum lift33 ft66 ft
Minimum circuit ampacity15 A15 A
Maximum fuse15 A20 A

Highlighted: changes at the next size

From 12,000 to 18,000 BTU/h. What changes: HSPF region IV, COP, outdoor sound, maximum line length, maximum lift and maximum fuse. What stays the same: SEER, HSPF region V, outdoor dimensions and minimum circuit ampacity.

See the 12,000 BTU/h product page

Values from the 03-21 brochure. The 06-21 revision prints the same figures, without HSPF region V, and gives the 30,000 and the 36,000 an outdoor unit of 37.25 × 16.14 × 31.9 in, which we use; the 03-21 brochure prints 37.25 × 16.25 × 32 in. GOODMAN publishes no test conditions for sound.

GOODMAN//In the room

The wall head, from 31.6 to 49.6 in wide

What you see and hear in the room, size by size. The 06-21 revision prints the same values as the 03-21 brochure.

GOODMAN data, sources 1 and 2, p. 5

Goodman Series 19, wall indoor unit
Published value12,00018,00024,00030,00036,000
Indoor unitMSH123E19AXAAMSH183E19AXAAMSH243E19AXAAMSH303E17AXAAMSH363E17AXAA
W × D × H, in31.6 × 7.5 × 11.738 × 8.5 × 12.642.5 × 9 × 13.249.6 × 11.1 × 14.2549.6 × 11.1 × 14.25
Sound high / medium / low, dB(A)38 / 32 / 2443 / 35 / 30.548 / 42.5 / 3452 / 44 / 3552 / 44 / 36
Airflow high / medium / low, cfm324 / 282 / 212449 / 393 / 262706 / 588 / 450795 / 618 / 471853 / 647 / 471

Highlighted: the 49.6 in wide head, the same for the 30,000 and the 36,000.

GOODMAN//At the rating point

Watts and amps, in cooling and in heating

What each size draws at the rating point. In cooling, the 36,000 draws 18.5 A against 4.5 A for the 12,000, more than four times as much (AirGreen calculation). The circuit itself is sized from the minimum circuit ampacity and maximum fuse in the 19 ladder.

GOODMAN data, sources 1 and 2, p. 5

Goodman Series 19, rated values
Published value12,00018,00024,00030,00036,000
Rated cooling, BTU/h12,00018,00024,00030,00036,000
Cooling input, W1,0651,6452,5002,8574,235
Cooling rated current, A4.57.3511.012.518.5
Rated heating at 8.3 °C, BTU/h12,00018,00024,00030,00036,000
Heating input, W1,0251,7002,2003,1103,835
Heating rated current, A4.37.49.613.516.7
R-410A charge, oz29.644.162.7997.0119.9

Power supply: 208-230 V single phase for all five sizes.

Compare//Same capacity

Series 19 or Series 21, at 18,000 BTU/h

Same size, same brochure. The circuit and the line set limits are identical; the published heating limit, the SEER and the footprint are not.

GOODMAN data, sources 1 and 2, p. 5 and 6

Series 19MSH183E19MCAA + MSH183E19AXAA
Series 21MSH183E21MCAA + MSH183E21AXAA
At 18,000 BTU/hSeries 19Series 21
SEER19.020.8
HSPF region IV / region V10.0 / 8.010.0 / 8.0
COP at 8.3 °C3.103.36
Heating published down to-15 °C-25 °C
Outdoor unit sound57.5 dB(A)60 dB(A)
Outdoor unit, W × D × H31.5 × 13.1 × 21.8 in33.27 × 14.29 × 27.64 in
Indoor unit, W × D × H38 × 8.5 × 12.6 in42.5 × 8.9 × 13.2 in
Maximum line length / maximum lift98 / 66 ft98 / 66 ft
Minimum circuit ampacity / maximum fuse15 / 20 A15 / 20 A

Series 21 sound: 06-21 revision; the 03-21 brochure prints 58.5 dB(A). Series 21 SEER: 20.8 in the 03-21 brochure, 21 in the 06-21 revision. See the Series 21 page.

Did you know//GOODMAN documents

Three Series 19 figures people read too fast

01

"19 SEER" is a ceiling, not an average

GOODMAN heads the Series 19 page "up to 19 SEER". Size by size, it publishes 19.0, 19.0, 17.0, 18.0 and 16.0: only the 12,000 and the 18,000 reach 19.

Source 1, p. 5
02

Three outdoor footprints for five sizes

The 12,000 and the 18,000 share an outdoor unit footprint, 31.5 × 13.1 × 21.8 in; so do the 30,000 and the 36,000, 37.25 × 16.14 × 31.9 in in the 06-21 revision. Only the 24,000 has its own, 33.3 × 14.3 × 27.7 in.

Source 1, p. 5; source 2, p. 5
03

EER drops from 11 to 8.5

In cooling, GOODMAN publishes an EER of 11, 11, 9.5, 10.5 and 8.5, from 12,000 to 36,000: the 36,000 uses the most power per BTU/h of cooling. The 03-21 brochure labels that line "COP"; the 06-21 revision calls it EER.

Source 1, p. 5; source 2, p. 5

AirGreen × GOODMAN//Who brings what

Series 19, from GOODMAN to your wall

GOODMANWhat GOODMAN brings

  • Five wall sizes, from 12,000 to 36,000 BTU/h, on R-410A
  • A SEER, an EER, an HSPF and a COP published for each size
  • Up to 213 ft of refrigerant line and a 98 ft lift on the 36,000
  • A published heating range of -15 to 30 °C

Questions//Series 19

Questions about Series 19

Which Series 19 size for my room?

GOODMAN prints no application area for Series 19; its 2018 French-language document gives one only for Series 15, 17 and 21. So the size is based on the room's heating needs: floor area, windows, insulation.

Down to what temperature does Series 19 heat?

GOODMAN publishes its heating from -15 to 30 °C outdoors for all five sizes, and publishes no cold-weather capacity. As with any wall heat pump, the heat delivered drops as it gets colder; the backup heat is chosen at the estimate.

Can a Series 19 head go on a multi-zone outdoor unit?

GOODMAN's documents do not provide for it: Series 19 only appears there as single zone. The multi-zone outdoor units of the same brochure, the MST…E21, refer to the Series 21 heads.

Can my existing refrigerant lines be reused?

That is checked on site. GOODMAN calls for 1/4 and 1/2 in lines on the 12,000 and the 18,000, and 3/8 and 5/8 in on the 24,000, the 30,000 and the 36,000. We also look at their condition and their length.

Why do the 30,000 and 36,000 carry the E17 code?

GOODMAN does not explain it. The 03-21 brochure prints them as MSH303E19 and MSH363E19, the 06-21 revision as MSH303E17 and MSH363E17. In the nomenclature of its 2018 French-language document, the two digits after the E stand for the nominal SEER; GOODMAN publishes a SEER of 18.0 for the 30,000 and 16.0 for the 36,000. AirGreen sells the E17 units.

Read next//The GOODMAN space

Related pages

AirGreen

Five sizes, one for your room

At the estimate, we measure the room, choose the wall for the head and the spot for the outdoor unit, then route the refrigerant lines between them. The size comes from the room's heating needs; the wall and the line route follow.

Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.

Free on-site estimate

An AirGreen technician assesses the heating and cooling needs, where the units will go and the refrigerant line route on site before proposing a model.

RBQ licence 5645-9605-01

Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.

The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.

Sources

  1. GOODMAN, "Heat Pump and Air Conditioner Ductless Units", 19 Series and 21 Series, code CB-DL-1921S-HP 03-21, p. 5 to 7. GOODMAN document kept in AirGreen's files.
  2. GOODMAN, same brochure, revision CB-DL-1921S-HP 06-21, p. 5 and 6.
  3. GOODMAN, French-language single and multi-zone ductless brochure, code CB-GDuctless2018-FR 10.18, p. 2 to 11: Series 15, 17 and 21 only.

Read and dated by AirGreen. Capacities and limits are the ones GOODMAN publishes; a real installation can give other values.