GOODMAN//Wall units//Series 19
Goodman Series 19 wall heat pump: five sizes, from 12,000 to 36,000 BTU/h
The only series that goes past 24,000 BTU/h among the GOODMAN wall units AirGreen sells. From one size to the next, the SEER, the outdoor sound, the line length and the fuse change, and not always the way you would expect. The ladder below lines them up, size against size.
The question this page answersWhich Goodman 19, from 12,000 to 36,000 BTU/h, and what changes from one size to the next?
The five Goodman 19 units we sell
From 12,000 to 36,000 BTU/h, each with its own product page and quote request.
Tool//The 19 ladder
The 19 ladder: one size, and what changes at the next
Pick a size. The table gives what GOODMAN publishes for it and for the size above; highlighted cells are the ones that change.
Goodman 19, 12,000 BTU/h
MSH123E19MCAA + MSH123E19AXAA
| Published value | 12,000 | 18,000next size |
|---|---|---|
| SEER | 19.0 | 19.0 |
| HSPF region IV | 9.5 | 10.0 |
| HSPF region V | 8.0 | 8.0 |
| COP at 8.3 °C | 3.43 | 3.10 |
| Outdoor unit sound | 55.0 dB(A) | 57.5 dB(A) |
| Outdoor unit, W × D × H | 31.5 × 13.1 × 21.8 in | 31.5 × 13.1 × 21.8 in |
| Maximum line length | 82 ft | 98 ft |
| Maximum lift | 33 ft | 66 ft |
| Minimum circuit ampacity | 15 A | 15 A |
| Maximum fuse | 15 A | 20 A |
Highlighted: changes at the next size
From 12,000 to 18,000 BTU/h. What changes: HSPF region IV, COP, outdoor sound, maximum line length, maximum lift and maximum fuse. What stays the same: SEER, HSPF region V, outdoor dimensions and minimum circuit ampacity.
See the 12,000 BTU/h product pageValues from the 03-21 brochure. The 06-21 revision prints the same figures, without HSPF region V, and gives the 30,000 and the 36,000 an outdoor unit of 37.25 × 16.14 × 31.9 in, which we use; the 03-21 brochure prints 37.25 × 16.25 × 32 in. GOODMAN publishes no test conditions for sound.
GOODMAN//In the room
The wall head, from 31.6 to 49.6 in wide
What you see and hear in the room, size by size. The 06-21 revision prints the same values as the 03-21 brochure.
GOODMAN data, sources 1 and 2, p. 5
| Published value | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|---|
| Indoor unit | MSH123E19AXAA | MSH183E19AXAA | MSH243E19AXAA | MSH303E17AXAA | MSH363E17AXAA |
| W × D × H, in | 31.6 × 7.5 × 11.7 | 38 × 8.5 × 12.6 | 42.5 × 9 × 13.2 | 49.6 × 11.1 × 14.25 | 49.6 × 11.1 × 14.25 |
| Sound high / medium / low, dB(A) | 38 / 32 / 24 | 43 / 35 / 30.5 | 48 / 42.5 / 34 | 52 / 44 / 35 | 52 / 44 / 36 |
| Airflow high / medium / low, cfm | 324 / 282 / 212 | 449 / 393 / 262 | 706 / 588 / 450 | 795 / 618 / 471 | 853 / 647 / 471 |
Highlighted: the 49.6 in wide head, the same for the 30,000 and the 36,000.
GOODMAN//At the rating point
Watts and amps, in cooling and in heating
What each size draws at the rating point. In cooling, the 36,000 draws 18.5 A against 4.5 A for the 12,000, more than four times as much (AirGreen calculation). The circuit itself is sized from the minimum circuit ampacity and maximum fuse in the 19 ladder.
GOODMAN data, sources 1 and 2, p. 5
| Published value | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|---|
| Rated cooling, BTU/h | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Cooling input, W | 1,065 | 1,645 | 2,500 | 2,857 | 4,235 |
| Cooling rated current, A | 4.5 | 7.35 | 11.0 | 12.5 | 18.5 |
| Rated heating at 8.3 °C, BTU/h | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Heating input, W | 1,025 | 1,700 | 2,200 | 3,110 | 3,835 |
| Heating rated current, A | 4.3 | 7.4 | 9.6 | 13.5 | 16.7 |
| R-410A charge, oz | 29.6 | 44.1 | 62.79 | 97.0 | 119.9 |
Power supply: 208-230 V single phase for all five sizes.
Compare//Same capacity
Series 19 or Series 21, at 18,000 BTU/h
Same size, same brochure. The circuit and the line set limits are identical; the published heating limit, the SEER and the footprint are not.
GOODMAN data, sources 1 and 2, p. 5 and 6
| At 18,000 BTU/h | Series 19 | Series 21 |
|---|---|---|
| SEER | 19.0 | 20.8 |
| HSPF region IV / region V | 10.0 / 8.0 | 10.0 / 8.0 |
| COP at 8.3 °C | 3.10 | 3.36 |
| Heating published down to | -15 °C | -25 °C |
| Outdoor unit sound | 57.5 dB(A) | 60 dB(A) |
| Outdoor unit, W × D × H | 31.5 × 13.1 × 21.8 in | 33.27 × 14.29 × 27.64 in |
| Indoor unit, W × D × H | 38 × 8.5 × 12.6 in | 42.5 × 8.9 × 13.2 in |
| Maximum line length / maximum lift | 98 / 66 ft | 98 / 66 ft |
| Minimum circuit ampacity / maximum fuse | 15 / 20 A | 15 / 20 A |
Series 21 sound: 06-21 revision; the 03-21 brochure prints 58.5 dB(A). Series 21 SEER: 20.8 in the 03-21 brochure, 21 in the 06-21 revision. See the Series 21 page.
Did you know//GOODMAN documents
Three Series 19 figures people read too fast
"19 SEER" is a ceiling, not an average
GOODMAN heads the Series 19 page "up to 19 SEER". Size by size, it publishes 19.0, 19.0, 17.0, 18.0 and 16.0: only the 12,000 and the 18,000 reach 19.
Source 1, p. 5Three outdoor footprints for five sizes
The 12,000 and the 18,000 share an outdoor unit footprint, 31.5 × 13.1 × 21.8 in; so do the 30,000 and the 36,000, 37.25 × 16.14 × 31.9 in in the 06-21 revision. Only the 24,000 has its own, 33.3 × 14.3 × 27.7 in.
Source 1, p. 5; source 2, p. 5EER drops from 11 to 8.5
In cooling, GOODMAN publishes an EER of 11, 11, 9.5, 10.5 and 8.5, from 12,000 to 36,000: the 36,000 uses the most power per BTU/h of cooling. The 03-21 brochure labels that line "COP"; the 06-21 revision calls it EER.
Source 1, p. 5; source 2, p. 5AirGreen × GOODMAN//Who brings what
Series 19, from GOODMAN to your wall
What GOODMAN brings
- Five wall sizes, from 12,000 to 36,000 BTU/h, on R-410A
- A SEER, an EER, an HSPF and a COP published for each size
- Up to 213 ft of refrigerant line and a 98 ft lift on the 36,000
- A published heating range of -15 to 30 °C
What AirGreen brings
- An on-site assessment of the heating needs, to choose among five sizes
- The wall for the head and the base for the outdoor unit, picked to fit their footprint
- Installation by our refrigeration technicians, under AirGreen's RBQ licence 5645-9605-01
- The refrigerant line route, within the limits GOODMAN publishes for each size
Questions//Series 19
Questions about Series 19
Which Series 19 size for my room?
GOODMAN prints no application area for Series 19; its 2018 French-language document gives one only for Series 15, 17 and 21. So the size is based on the room's heating needs: floor area, windows, insulation.
Down to what temperature does Series 19 heat?
GOODMAN publishes its heating from -15 to 30 °C outdoors for all five sizes, and publishes no cold-weather capacity. As with any wall heat pump, the heat delivered drops as it gets colder; the backup heat is chosen at the estimate.
Can a Series 19 head go on a multi-zone outdoor unit?
GOODMAN's documents do not provide for it: Series 19 only appears there as single zone. The multi-zone outdoor units of the same brochure, the MST…E21, refer to the Series 21 heads.
Can my existing refrigerant lines be reused?
That is checked on site. GOODMAN calls for 1/4 and 1/2 in lines on the 12,000 and the 18,000, and 3/8 and 5/8 in on the 24,000, the 30,000 and the 36,000. We also look at their condition and their length.
Why do the 30,000 and 36,000 carry the E17 code?
GOODMAN does not explain it. The 03-21 brochure prints them as MSH303E19 and MSH363E19, the 06-21 revision as MSH303E17 and MSH363E17. In the nomenclature of its 2018 French-language document, the two digits after the E stand for the nominal SEER; GOODMAN publishes a SEER of 18.0 for the 30,000 and 16.0 for the 36,000. AirGreen sells the E17 units.
Read next//The GOODMAN space
Related pages
Five sizes, one for your room
At the estimate, we measure the room, choose the wall for the head and the spot for the outdoor unit, then route the refrigerant lines between them. The size comes from the room's heating needs; the wall and the line route follow.
Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.
An AirGreen technician assesses the heating and cooling needs, where the units will go and the refrigerant line route on site before proposing a model.
Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.
The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.
Sources
- GOODMAN, "Heat Pump and Air Conditioner Ductless Units", 19 Series and 21 Series, code CB-DL-1921S-HP 03-21, p. 5 to 7. GOODMAN document kept in AirGreen's files.
- GOODMAN, same brochure, revision CB-DL-1921S-HP 06-21, p. 5 and 6.
- GOODMAN, French-language single and multi-zone ductless brochure, code CB-GDuctless2018-FR 10.18, p. 2 to 11: Series 15, 17 and 21 only.
Read and dated by AirGreen. Capacities and limits are the ones GOODMAN publishes; a real installation can give other values.