Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
GREE packaged heat pumps. One cabinet on the roof, connected to your ducts. How much heat at −30 °C? The certified records answer, size by size. LogisVert? The list carries all four sizes; the guide names only split and mini-split systems.
4 GREE Rooftop R32 packaged heat pumps, from 24,000 to 60,000 BTU/h. For a flat-roof plex, shop or house that already has ductwork. Compressor, coils and fan sit in one cabinet on the roof: no indoor unit, no refrigerant line set inside the building. What is left is picking the size, and checking what the roof and the electrical panel will take.
- 4sizes on this page
- 2–5tons, from 24,000 to 60,000 BTU/h
- 4/4ENERGY STAR cold climate, checked by AHRI number
- 208-230 Vsingle phase, all four sizes
Four sizes, four temperatures. See what each one delivers.
Tonnage says little about winter. The NEEP and ENERGY STAR records of each AHRI number say a lot: from 8.3 °C down to −30 °C, with the rated value wherever one exists.
Winter, size by size
All four AHRI numbers have a NEEP record and an ENERGY STAR cold-climate record. Pick a size: the answer shows the maximum heat published at four temperatures, then the LogisVert arithmetic.
At −15 °C, the 3-ton matches the 2-ton
ENERGY STAR rates the 2-ton and the 3-ton at 29,000 BTU/h at −15 °C, and the 4-ton and the 5-ton at 51,000. The gap between neighbouring sizes comes back at −8.3 °C and −30 °C. For all four sizes, NEEP and ENERGY STAR publish more heat at −15 °C than at −8.3 °C: we show their values as published.
What GREE ships, and what gets prepared on site.
A packaged unit moves the work to the roof. GREE ships the complete cabinet; four things remain to plan on site.
Shipped by GREE
- One cabinetCompressor, coils and fan in a cabinet 1,250 mm tall. The supply and return ducts connect straight to it.
- The R32, factory-charged4.25 kg in the 2- and 3-ton, 5.8 kg in the 4- and 5-ton. That charge also sets a minimum room area: see the technician’s corner.
- The GREE wired controllerIncluded, on two non-polarized wires, up to 98.5 ft (30 m) from the unit. A 24 V thermostat can take its place: the “Thermostat” tool below explains the setting.
- A 160 W base pan heaterPer NEEP, it turns on below 33.8 °F (1 °C) outdoors or during defrost.
To plan on site
- The roof curbGREE does not supply it. The manual gives its reference dimensions; the supply and return ducts are built on site, inside the curb.
- Which way the ducts goDown through the base pan, or out the side of the cabinet: the covers come off the opening you choose.
- Backup heatNone from the factory. GREE allows only its LYQ-08 kits of 6, 9 or 12 kW, listed for all four sizes.
- The load on the roof237.0 kg net for the 2- and 3-ton, 285.0 kg for the 4- and 5-ton, on a footprint of 1,120 × 900 mm or 1,120 × 1,120 mm.
One cabinet on the roof, a local team to connect it.
GREE designs the Rooftop R32 and its heater kits. AirGreen picks the size from the certified figures and installs the unit; the roof curb and the roof waterproofing are coordinated in the quote with a roofer holding the licence that applies.
What GREE brings
- Two-stage compressionTwo cylinders and hot gas injection: the technology GREE highlights for cold weather.
- Residential and light commercialWhat GREE intends the line for, from 2 to 5 tons, on 208-230 V single phase.
- R-32 with a GWP of 675The global warming potential ENERGY STAR lists for its refrigerant.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateWe check the roof curb, the ducts and the electrical panel, then pick the size with you.
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: one GREE cabinet on the roof, cold-climate certified, connected to your ducts by a GREE Elite dealer.
The 4 Rooftop R32 sizes, as full product sheets.
Each product sheet gives the AHRI number of its size and its specifications. The certified capacities are in the ladder at the top of the page.
Day to day: controls and sound.
Two tools drawn from GREE Canada’s manual and brochure, so you come to the visit with the right questions.
24 V thermostat or GREE controller?
The Rooftop R32 takes either one. Tell us what you want to do: the answer comes from GREE Canada’s owner’s manual.
On the roof, but close to the neighbours: how loud?
GREE Canada publishes a sound pressure of 63 dB(A) for the 2- and 3-ton and 68 dB(A) for the 4- and 5-ton, without stating the measuring distance. Sound power: 73 and 78 dB(A).
Roof, ducts, circuit: the technician’s numbers.
The circuit
208-230 V, 60 Hz, single phase. Per GREE Canada: MCA 40 A and a 40 A breaker for the 2- and 3-ton; MCA 39.1 A and a 45 A breaker for the 4- and 5-ton. The circuit is sized from the unit’s nameplate.
GREE Canada, brochure 032026Airflow and static pressure
Rated external static pressure of 125 Pa (0.50 in. w.c.) on all four sizes. Range of 0 to 175 Pa for the 2- and 3-ton per the brochure, but 0 to 200 Pa in the 3-ton submittal; 0 to 200 Pa for the 4- and 5-ton. High-speed airflow: 880, 1,120, 1,350 and 1,600 CFM.
Brochure 032026 · 3-ton submittalThe R32 and the minimum room area
For 4.25 kg of R32, the manual sets a minimum room area of 12.7 m² (135.9 ft²); for 5.8 kg, 17.3 m² (185.5 ft²). Calculated for a 2.2 m room height.
RTU R32 owner’s manualEfficiency
SEER2 of 18.0 on all four sizes; HSPF2 of 8.8, 8.5, 8.5 and 8.3; EER2 of 11.7 on the 2-ton and 11.2 on the other three. COP of 3.40 at 8 °C.
GREE Canada, brochure 032026 · ENERGY STARSix Rooftop R32 details you rarely read on a spec sheet.
On the LogisVert list. To be confirmed for a packaged unit.
Before you count on it
LogisVert guide v1.10 defines the eligible system as an air-to-air split (central) or mini-split (wall-mounted) heat pump, always with an outdoor unit and at least one indoor unit; the word for a packaged unit (monobloc) does not appear in it. It also excludes an air distribution network placed outside the insulation envelope, for example in the attic. So whether a packaged unit qualifies has to be confirmed in writing with Hydro-Québec before it goes into your budget.
All four amounts come from Hydro-Québec’s list dated Oct. 27, 2026 and stay indicative until Hydro-Québec confirms them on your application. Guide formula: $120 per 1,000 BTU/h at −8 °C, ENERGY STAR value, for an ENERGY STAR cold-climate heat pump.
Roof, cold, LogisVert: your questions on GREE packaged units.
Does LogisVert pay for a packaged rooftop heat pump on a house?
How much heat does it give at −30 °C?
Will the Rooftop R32 work with my 24 V thermostat?
Is there electric backup heat?
What has to be ready on the roof?
Which size do I need?
A flat roof and ductwork? We go up to look at the curb, then work out the winter with you.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- National Building Code of Canada 2020, Appendix C, Table C-2 (Montréal, City Hall)
- Québec.ca, “Mesure du bruit” (in French), examples of noise sources (updated June 16, 2022), read Oct. 14, 2026
- AirGreen GREE page: Elite status and installations, facts checked Oct. 5, 2026; GREE installation count of Oct. 14, 2026
- GREE Canada, Rooftop R32 brochure (packaged heat pump), document No. 032026, read Oct. 26, 2026
- GREE Canada, RTU R32 owner’s manual: roof curb, ducts, LYQ-08 kits, controls, minimum room area; read Oct. 26, 2026
- GREE Canada, 3- and 5-ton submittals and AHRI certificates 215866830 and 215866831, read Oct. 26, 2026
- ENERGY STAR, air-source heat pump key product criteria: definition of a single package unit, read Oct. 26, 2026
Certified capacities: NEEP and ENERGY STAR, by AHRI number. LogisVert amounts: list of Oct. 27, 2026, indicative, eligibility of a packaged unit to be confirmed. Ladder arithmetic: AirGreen. Page updated Oct. 26, 2026.