AirGreenGREE
GREE EliteThe GREE space at AirGreen · Electric furnacesGREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
R-32 and R-410A · backup heat optional
GREE electric furnace · air handler · Updated Oct. 27, 2026

GREE electric furnaces. At GREE, the “furnace” is the air handler of a central heat pump. The electric heat? A kit added inside it, for the days the heat pump can’t keep up.

24 GREE listings, 2 to 5 tons, in 6 air-handler families. Replacing an electric furnace? Here the heat comes from the heat pump first, then from a backup kit inside the cabinet. It comes down to two choices: the air handler, and the kit it accepts.

0 kWElectric heat installed at the factory. The air handlers GREE documents ship without it: the kit is added as an accessory, in the size chosen.
3,413 BTU/hPer kilowatt of heat kit, per Natural Resources Canada. A 10 kW kit therefore adds 34,130 BTU/h at its rated power.
7 or 4Heat-kit sizes GREE provides for a 4- or 5-ton air handler: seven for the FLEXX ULTRA’s FXU, four for the UNIX R32’s GUD..AH2/G.
  • 24listings on this page
  • 6air-handler families
  • 2–5tons
  • 5 to 20 kWGREE heat kits published, by air handler
AirGreen × GREEGREE Elite dealerAir handler and backup heat kitRBQ licence 16: the circuit too48 GREE furnaces on our installations blogMontréal, Laval, Longueuil, South Shore, North Shore
Five air handlers side by side

Same tonnage, five GREE air handlers. What actually changes?

Pick the size. The table puts the five air-handler families documented or sold here side by side: dimensions, heat kits, airflow, static pressure and blower circuit, as each maker prints them.

Pick the tonnage

Left to right: two documented R-32 air handlers, one R-32 air handler with no published sheet, then two previous-generation R-410A air handlers. Read it row by row: that is where the families part ways.

Sources: GREE Comfort FLEXX ULTRA R32 brochure and heat-kit chart (FXU); GREE Canada UNIX R32 brochure and GREE manual X40273A (GUD..AH2/G); GREE Comfort 2023 catalog (FLEXX..BH); GREE Canada brochure 052024 (GUD..AH2/A). No GUD..AH2/E sheet is published as of Oct. 26, 2026. “Up to” is a maximum, “rated” is the rating point: the two do not compare. The FLEXX..AH air handler (R-410A) appears in no GREE document we read.

When the backup takes over

Heat pump first, heat kit second. Where is the line?

Natural Resources Canada has precise words for this hand-off. Here they are in the order winter brings them, with Montréal’s design day.

  1. Mild to coldThe heat pump aloneAs long as it supplies as much heat as the house loses, the backup has nothing to do.
  2. Balance pointThe two curves crossNRCan: the temperature where the heating load line crosses the heat pump’s capacity curve. It depends on your house as much as on the equipment.
  3. ColderThe kit fills the gapThat is backup heat as NRCan defines it: a backup system, needed if or when the heat pump no longer supplies enough heat.
  4. Cut-offBackup onlyBelow the cut-off temperature, if there is one, the heat pump stops running; the backup then heats the whole building, NRCan notes.
−23 °CMontréal’s January design temperature, at 2.5%. NEEP publishes points at −8 °C, −15 °C and −30 °C for these systems, none at −23 °C.National Building Code 2020, Appendix C · NEEP
−26 °CJanuary design temperature at 1%, harsher than the −23 °C at 2.5%. The Code gives both for Montréal.National Building Code 2020, Appendix C
18,000 BTU/hAt most, at −30 °C, for each of the three 2-ton R-32 pairs on this page. The other tonnages are on the central heat pump pages.NEEP, AHRI 216621482, 215213329 and 217120759
34,130 BTU/hWhat a 10 kW kit adds at its rated power: 10 × 3,413. That is how a furnace’s kilowatts compare with a heat pump’s BTU/h.NRCan · AirGreen’s arithmetic

The kit’s circuit is electrical work

RBQ subcategory 16 covers electrical installations and permanently connected appliances; this work is reserved for electrical contractors. AirGreen holds 16 along with 15.8 and 15.10: the air handler, the heat pump and the kit’s circuit fall under our licences. Gas and oil: a licensed partner.

The six families on this page

Six air-handler families, six levels of documentation.

The listings on this page come from several distribution networks and two generations. Before you choose, here is what each family actually has in print.

Air handlerWhat is publishedGood to know
FXU..AHFLEXX ULTRA · R-32
Kits and circuits
GREE Comfort chart of May 28, 2026: seven kits, 5 to 20 kW, by tonnage. The submittals give, kit by kit, the kW at 208 and 230 V, the minimum circuit and the maximum breaker. See the FXU air handler
GUD..AH2/GUNIX R32 · R-32
Kits, no circuit table
The GREE manual lists four LYQ-08 kits, 5, 10, 15 and 20 kW, by tonnage. GREE Canada leaves the kit’s circuit to the certified technician. See the UNIX R32 air handler
GUD..AH2/EFLEXX R32 · R-32
No sheet
Dettson and ENERGY STAR list it under four AHRI numbers, but the technical documents Dettson links to the series describe the /G air handler. Kit and circuit: confirmed in the quote. See the /E air handler
FLEXX..BHFLEXX · R-410A
Kits published
GREE Comfort’s 2023 catalog gives 5, 8 and 10 kW (24), 5, 8, 10 and 15 kW (36), 10, 15 and 20 kW (48 and 60). Sold as an air handler alone: its listing carries no system AHRI number.
FLEXX..AHFLEXX · R-410A, with FLEXX..AO
No document
No GREE document we read names a FLEXX..AH air handler. Pairing, kit and certification: to be confirmed in the quote.
GUD..AH2/AUNIX · R-410A
Kit sizes not given
GREE Canada’s brochure 052024 gives 960 to 1,600 CFM and an optional auxiliary heater, with no sizes or circuit: the certified technician sets them. Pairing and certification: to be confirmed in the quote.

The certified capacities and LogisVert amounts of each system are on the central heat pump pages: FLEXX ULTRA R32 · FLEXX R32 (Dettson) · UNIX R32.

AirGreen × GREE

The air handler, the kit and the circuit, in one place.

GREE designs the air handler and publishes the kits it accepts. AirGreen picks the tonnage, the kit and the circuit, then installs it all.

GREE

What GREE brings

  • Kits by tonnageSeven sizes for the FXU, 5 to 20 kW; four for the GUD..AH2/G. In both families, the 20 kW kit needs a 4-ton air handler or larger.
  • A leak sensor on R-32GREE Comfort factory-installs the FXU’s A2L sensor; GREE Canada lists a leak detector on all of its air handlers.
  • A 24 V thermostatGREE Comfort and GREE Canada list their R-32 air handlers as compatible with standard 24 V thermostats.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe look at your ducts and your electrical panel, then choose the kit with you.
  • 48 GREE furnacesGREE air handlers installed by AirGreen and published with photos on our installations blog (count as of Oct. 14, 2026).
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: a home heated by the heat pump first, with a correctly sized GREE kit for the coldest days.

The GREE shop

All 24 GREE electric furnace listings, right below.

The R-32 listings give the AHRI number of the complete heat pump; the FLEXX..BH air handlers are sold alone. The heat kit is chosen separately, to suit the air handler.

GREE
Know before you buy

Before you choose: the kit size, the refrigerant.

Two tools built from GREE documents. They prepare the visit; the heat-loss calculation, done at your home, sets the kit size.

From kilowatts to BTU/h, and the air handlers that take that kit

Pick a size in kilowatts. The tool converts it to BTU/h, the unit heat pumps use, then gives, family by family, the tonnages for which GREE publishes a kit of that size.

Technician’s corner

Air handler and kit: the figures that matter on site.

Two R-32 kit families

FXU: FLEXA2LHTR kits of 5, 6, 9, 10, 12, 15 and 20 kW. GUD..AH2/G: LYQ-08 kits of 5, 10, 15 and 20 kW, described as breaker and heat strip. Each air handler has its own list; we order from the one for the unit installed.

GREE Comfort chart 05282026 · GREE manual X40273A

Static pressure, published three ways

GREE Comfort: “up to” 1.0 in. w.c. for the FXU and FLEXX..BH. GREE Canada: 0.5 in. w.c. (125 Pa) rated for the GUD..AH2/G, and 0.10 to 0.20 in. w.c. for the GUD..AH2/A. A maximum and a rating point do not compare.

GREE Comfort and GREE Canada brochures

The blower alone, then the kit

Without a kit, the minimum circuit runs from 4.7 to 7.7 A for the FXU and GUD..AH2/G, and 4 to 8 A for the documented R-410A air handlers, with 15 A protection. With the kit, GREE Comfort publishes a table per kit for the FXU; GREE Canada leaves the MCA and MOP to the certified technician.

GREE Comfort · GREE Canada

RBQ 15.8, for the ducts

Subcategory 15.8 covers ductwork and placing the heating appliances of a forced-air system; with 15.10, it also covers the heating and cooling appliances themselves.

RBQ, list of subcategories
Did you know?

Six cards to talk backup heat like a technician.

LogisVert · Hydro-Québec

LogisVert follows the heat pump, not the kit.

12R-32 listings on this page whose AHRI number is on Hydro-Québec’s list of Oct. 27, 2026: FXU, GUD..AH2/G and GUD..AH2/E, 2 to 5 tons.
$120per 1,000 BTU/h of ENERGY STAR capacity at −8 °C (17 °F), for an ENERGY STAR cold-climate system. The heat kit is not part of this calculation.
$50per 1,000 BTU/h if the system is ENERGY STAR without the cold-climate designation. The amount never exceeds the pre-tax cost.
R-410APairing and eligibility to be confirmed in the quote, AHRI number in hand.

Rules from the LogisVert participant guide, version 1.10, Sept. 15, 2026. Each system’s indicative amount, by tonnage, is on its central heat pump page: FLEXX ULTRA R32 · FLEXX R32 (Dettson) · UNIX R32; Hydro-Québec confirms it once you apply.

Questions

The questions that come up when replacing an electric furnace.

Is a GREE “electric furnace” really a furnace?
It is the indoor unit of a central heat pump: an air handler with its coil and blower. GREE ships it without electric heat; the backup kit is added inside the cabinet as an accessory. GREE Canada calls it optional in both of its UNIX brochures.
Which heat kit fits my air handler?
It depends on the family and the tonnage. The FXU takes FLEXA2LHTR kits from 5 to 20 kW per GREE Comfort’s chart; the GUD..AH2/G, LYQ-08 kits from 5 to 20 kW per the GREE manual; the FLEXX..BH, 5 to 20 kW per the 2023 catalog. For the GUD..AH2/E and GUD..AH2/A, no size is published: we confirm it in the quote.
What heats the house at −30 °C?
Below your home’s balance point, the heat pump and the kit heat together; NEEP still lists a heating capacity at −30 °C for the R-32 systems on this page. The National Building Code gives Montréal design temperatures of −23 °C (2.5%) and −26 °C (1%). The heat-loss calculation done at your home says how much falls to the kit.
How much heat does a 10 kW kit add?
34,130 BTU/h at its rated power: NRCan counts 3,413 BTU/h per kilowatt. On the actual voltage it is less: GREE Comfort publishes 4.6 kW at 230 V and 3.74 kW at 208 V for its 5 kW kit. The FXU page gives these values kit by kit.
Will my current thermostat work?
The GREE documents do not all say the same thing. GREE Canada lists the UNIX R32 as compatible with most standard 24 V wired thermostats, and GREE Comfort says any standard 24-volt heat pump thermostat runs the FLEXX R32; the GREE air-handler manuals, for their part, give the WK-010WC1 as the required thermostat. So we check your model at the visit. To choose a new one, see the GREE thermostats page.
Who does the electrical work for the kit?
An electrical contractor: RBQ subcategory 16 reserves electrical installations for them. AirGreen holds it, along with 15.8 and 15.10. Gas or oil work goes to a licensed partner.
AirGreen

Electric furnace on its last legs? We choose the air handler, the kit and the circuit, and install it all.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
48 GREE furnacesPublished with photos on our installations blog, counted on Oct. 14, 2026.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
Dated documentsEvery heat-kit size on this page comes from a dated document, cited below.
Sources

Heat kits and electrical values: as printed by each document; the nameplate of the delivered unit decides. kW to BTU/h conversions: AirGreen’s arithmetic, with NRCan’s factor. LogisVert amounts: indicative. Page updated Oct. 28, 2026; NEEP and ENERGY STAR records checked again Oct. 26, 2026, LogisVert list dated Oct. 27, 2026.