Added to comparison
-
Added to comparison
-
Added to comparison
GREE Free Match Extreme triple-zone heat pumps. Three rooms on a line that left the lists in October 2026. Is what GREE Canada still publishes enough to pick the size?
3 three-room Free Match Extreme systems, from 24,000 to 42,000 BTU/h. Three bedrooms, or two bedrooms and a basement. Since late October 2026, NEEP, ENERGY STAR and the LogisVert list no longer carry the AHRI numbers of these three systems; GREE Canada still publishes their capacities and limits, and that is what the choice rests on.
- 3three-room systems on this page
- 24,000–42,000BTU/h, nominal
- 3units: the 24,000’s maximum, per GREE Canada
- 0public table of three-unit combinations
Three sizes, three lists: when each status went.
AHRI numbers 202557961, 202557962 and 202557963 were still listed in mid-October. Here is when each list last carried them, and when it dropped them.
- Oct. 14–15, 2026Still everywhereNEEP: three “Live” records, modified Aug. 24, 2026. ENERGY STAR: “cold climate”, certified June 13, 2026. Hydro-Québec: all three sizes on the LogisVert list of Oct. 15.
- Oct. 25, 2026ENERGY STARThe dataset update removes all three AHRI numbers. ENERGY STAR keeps the non-ducted 18,000, designed for two rooms only.
- Oct. 26, 2026NEEPThe scan of the GREE brand and the search by AHRI number return nothing for the 24,000, 36,000 and 42,000.
- Oct. 27, 2026Hydro-QuébecThe LogisVert list dated that day carries none of the three numbers: no amount left for these systems.
NEEP records read Oct. 15, 2026, then checked again on the 26th; ENERGY STAR datasets of Oct. 14 and 25; Hydro-Québec LogisVert lists of Oct. 15 and 27. The ducted numbers GREE Canada prints for these three sizes were not checked on ENERGY STAR or the LogisVert list. GREE Canada still shows the line in its multi-zone collection on Oct. 26.
Three sizes for three rooms, row by row.
Without a NEEP record, the 062024 brochure is what remains. It is enough to rule a size out; it does not say what each room gets.
| Per GREE Canada | 24,000 | 36,000 | 42,000 |
|---|---|---|---|
| Indoor units | 2 to 3 | 2 to 4 | 2 to 5 |
| System heating (range) | 26,000 (7,500 – 31,000) | 36,000 (8,871 – 44,356) | 42,000 (10,236 – 46,744) |
| System cooling (range) | 22,000 (7,500 – 30,000) | 36,000 (8,871 – 35,826) | 42,000 (10,236 – 38,214) |
| COP | 3.60 | 3.21 | 3.40 |
| Maximum height difference | 8 m | 15 m | 15 m |
| “From ODU to last IDU” | 70 m | 75 m | 80 m |
| “Maximum Pipe Length” | 25 m | 25 m | 25 m |
GREE Canada, document No. 062024, read in English and French on Oct. 26, 2026. Both length rows are shown as printed. The heating and cooling figures are the brochure’s, with no temperature stated: they are not certified deep-cold figures.
No public combination table
GREE Canada gives the number of units per size and the compatible indoor-unit families, but neither the list of allowed trios nor each room’s heat. We validate your combination before the quote.
24,000, 36,000 or 42,000: two questions are enough to rule a size out.
Height difference and the number of units in the end are the two limits GREE Canada publishes size by size. The heat each room needs is calculated at your home.
Your home, three rooms
Answer the two questions: the sizes that remain possible show up, with what sets them apart.
Three rooms on a certified system: the Free Match M R32 publishes each one’s share.
The Free Match Extreme stays on sale while stocks last. This comparison does not judge it: it shows what GREE Canada’s R-32 line adds for three rooms.
| Three rooms | Free Match Extreme | Free Match M R32 |
|---|---|---|
| Refrigerant | R-410A | R-32 |
| NEEP and ENERGY STAR | No NEEP record; non-ducted numbers removed from ENERGY STAR in October 2026 | Every size from 24,000 to 42,000, “cold climate” |
| LogisVert, list of Oct. 27, 2026 | No amount | $2,832 to $5,340 |
| Each room’s share | Not published | Printed for every trio in its table |
| Height difference on the 24,000 | 8 m | 15 m |
Free Match M R32: GREE Canada, document No. 092026 and combination tables; NEEP and ENERGY STAR read Oct. 26, 2026; indicative amounts. The room-by-room tool is on the Triple-zone page.
Three rooms on a Free Match Extreme: who does what.
GREE Canada documents the outdoor unit and publishes its limits. AirGreen calculates each room, validates the trio of indoor units and installs the system.
What GREE brings
- Up to five units on the 42,000Four on the 36,000, three on the 24,000, per the 062024 brochure.
- Four indoor-unit formatsLOMO 23, Crossover and Extreme wall units, mini floor consoles, ceiling cassettes and slim ducts, to mix from room to room.
- Capacities published by sizeSystem heating and cooling, with their range, for the 24,000, 36,000 and 42,000.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateWe calculate the heat loss of all three rooms, then validate the trio of units before quoting you a price.
- 30 Free Match Extreme jobsAll sizes and room counts: each job has its own article and photos on our installations blog (count as of Oct. 14, 2026).
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas, oil and hot-water heating work is done by a licensed partner.
The result: three rooms on a Free Match Extreme picked within the limits GREE Canada publishes, installed by a GREE Elite dealer.
All 3 three-room Free Match Extreme systems, right below.
The three product sheets give each outdoor unit model. The dates of removal from NEEP, ENERGY STAR and LogisVert are in the timeline at the top of the page.
Three rooms, one unit outside: sound, size by size.
The sound pressure figures of the 062024 brochure, compared with everyday sounds. The measuring distance is not published: it is an order of magnitude, not a measurement at your home.
A 36,000 in the yard for three bedrooms: how loud?
GREE Canada gives 60 dB(A) for the 24,000 and 62 dB(A) for both the 36,000 and 42,000. Pick a size to place it on Québec.ca’s scale.
Three rooms: what the electrician and the installer will read in the 062024 brochure.
Circuit and power input
208-230 V single phase. MCA and maximum overcurrent protection: 23 A and 40 A (24,000), 36 A and 60 A (36,000), 38 A and 60 A (42,000). In rated heating, GREE Canada gives 2,090, 3,300 and 3,600 W. Our RBQ 16 licence covers the circuit.
GREE Canada 062024Airflow and cabinet
4,300 m³/h (2,531 CFM) on the 24,000, 5,200 m³/h (3,060 CFM) on the 36,000 and 42,000. Cabinet of 1003 × 790 × 417 mm and 79 kg net for the 24,000; 1095 × 1103 × 440 mm and 127 or 128 kg for the other two.
GREE Canada 062024Charge and lines
2.7 kg of R-410A from the factory on the 24,000, 4.5 kg on the 36,000, 5.0 kg on the 42,000. 1/4 in (liquid) and 3/8 in (suction) lines at every size. The brochure gives no pre-charged length for this line.
GREE Canada 062024Ducted or not
Non-ducted: SEER2 20.0, EER2 12.0 and HSPF2 10.0 on the 24,000; 16.0, 9.0 and 8.6 on the 36,000 and 42,000. Ducted: 14.5, 8.5 and 7.8, then 14.5, 8.0 and 7.6. GREE Canada prints an AHRI number for each case.
GREE Canada 062024Four things to know about the three-room Free Match Extreme. Flip the cards.
LogisVert: what the list said on Oct. 15, and what it says on Oct. 27.
Amounts are indicative: only Hydro-Québec confirms them, when the application is filed. Program rates and conditions: GREE multi-zone page.
What people ask us about the three-room Free Match Extreme.
Is a three-room Free Match Extreme still certified?
Which size for three rooms?
Which indoor units can be combined?
Does GREE Canada say what each room gets?
Can the third room be on another floor?
And the warranty?
Three rooms on a Free Match Extreme? We calculate each room, then validate the trio.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- NEEP, check by AHRI number on Oct. 26, 2026: Free Match Extreme ND3J/O and Multi+ Ultra V1DO removed from the list
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- GREE Canada, “Multi-zone system FREE MATCH M R32” brochure, document No. 092026, file version of Oct. 14, 2026 on GREE Canada’s site, read Oct. 14, 2026, same version on Oct. 26, 2026
- GREE Canada, “FREE MATCH M R32” data sheet, allowed-combination tables, file version of Oct. 14, 2026, read Oct. 14, 2026, same version on Oct. 26, 2026
- GREE Comfort (USA), Multi+ Ultra submittals, 18,000 to 42,000, dated May 15, 2023, read Oct. 26 and 27, 2026
- Québec.ca, “Mesure du bruit” (in French), examples of noise sources (updated June 16, 2022), read Oct. 14, 2026
- AirGreen GREE page: Elite status and installations, facts checked Oct. 5, 2026; GREE installation count of Oct. 14, 2026
- GREE Canada, Free Match Extreme brochure (R-410A), document No. 062024, English and French versions, read Oct. 26, 2026
- GREE Canada, “Multi-zone Mini-Splits” collection and “Free Match Extreme J Series” page, read Oct. 26, 2026
- NEEP, records by AHRI number read Oct. 15, 2026 (status “Live”, modified Aug. 24, 2026)
- ENERGY STAR, dataset w7cv-9xjt updated Oct. 14, 2026, read the same day (records removed since)
- Hydro-Québec, LogisVert eligible heat pump list, file of Oct. 15, 2026 (used to date the removals)
Capacities and amounts: indicative, to be confirmed in the quote. Tool calculations: AirGreen, from the published values above. Page updated Oct. 27, 2026; NEEP records, ENERGY STAR and the LogisVert list checked again that day.