Each card counts only the two-room systems on this page: lowest point catalogued by NEEP, maximum capacities at −15 °C and −8 °C, ENERGY STAR designation and LogisVert amount from the list.
R-32Current generation
Free Match M R32 (FreeMatch R32)
GWHD(18)ND6MO, GWHD(24)ND6MO, GWHD(30)ND6MO, GWHD(36)ND6MO, GWHD(42)ND6MO
- −30 °Clowest point catalogued by NEEP
- 37,800max. BTU/h at −15 °C (NEEP)
- 44,500max. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
ENERGY STAR cold climate for every system
LogisVert up to $5,340 indicative
For two rooms: six combinations on the 18,000, from 5+5 to 12+12, and eight on the 24,000, per GREE Canada’s table. The 18,000 takes no third unit.
R-32Current generation
MULTI R32
MUL18HP230V1R32AO, MUL24HP230V1R32AO, MUL30HP230V1R32AO, MUL36HP230V1R32AO, MUL42HP230V1R32AO
- −30 °Clowest point catalogued by NEEP
- 37,800max. BTU/h at −15 °C (NEEP)
- 44,500max. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
ENERGY STAR cold climate for every system
LogisVert up to $5,340 indicative
For two small rooms, the 18,000 earns $192 less than the Free Match M R32 of the same size: $1,920 versus $2,112, per Hydro-Québec’s list.
R-410APrevious generation · while stocks last
Free Match M Series
GWHD(18)ND3MO, GWHD(24)ND3MO, GWHD(30)ND3MO, GWHD(36)ND3MO, GWHD(42)ND3MO
- −30 °Clowest point catalogued by NEEP
- 32,400max. BTU/h at −15 °C (NEEP)
- 38,200max. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
ENERGY STAR cold climate for every system
LogisVert up to $4,272 indicative
At −15 °C the 18,000 has a certified COP of 2.21 per NEEP, versus 2.00 for the Free Match M R32 of the same size.
R-410APrevious generation · while stocks last
Multi GEN2
MULTI18HP230V1EO, MULTI24HP230V1EO, MULTI30HP230V1EO, MULTI36HP230V1EO, MULTI42HP230V1EO
- −30 °Clowest point catalogued by NEEP
- 32,400max. BTU/h at −15 °C (NEEP)
- 38,200max. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
ENERGY STAR cold climate for 1 of 5 systems
LogisVert up to $1,800 indicative
The 18,000 earns $1,800, like the M Series of the same size. At 42,000 BTU/h the gap with the M Series reaches $2,492: $1,780 versus $4,272.
R-410APrevious generation · while stocks last
Free Match Extreme
GWHD(18)ND3J/O, GWHD(24)ND3J/O, GWHD(36)ND3J/O, GWHD(42)ND3J/O
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 4 systems
No ENERGY STAR record found for these AHRI numbers
For two rooms: 18,000, 24,000, 36,000 or 42,000 BTU/h. At 18,000, GREE Canada publishes 21,000 BTU/h of rated heating, modulating from 7,000 to 26,000. The line is no longer on NEEP as of Oct. 26, 2026.
R-410APrevious generation · while stocks last
Multi+ Ultra
MULTIU18HP230V1DO, MULTIU24HP230V1DO, MULTIU36HP230V1DO, MULTIU42HP230V1DO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 4 systems
No ENERGY STAR record found for these AHRI numbers
A MULTIU…HP230V1DO outdoor unit for two indoor units, documented by GREE Comfort in the United States. Since it left NEEP and ENERGY STAR, its heat in deep cold can no longer be compared on certified figures.
R-410APrevious generation · while stocks last
Free Match (first generation)
GWHD(18)ND3GO, GWHD(24)ND3GO, GWHD(30)ND3GO, GWHD(36)ND3GO, GWHD(42)ND3EO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
No ENERGY STAR record found for these AHRI numbers
No public GREE Canada sheet and no NEEP figures. For two rooms, the Free Match M R32 of the same size is certified and on the LogisVert list.
R-410APrevious generation · while stocks last
Multi21+
MULTI18HP230V1CO, MULTI24HP230V1CO, MULTI30HP230V1CO, MULTI36HP230V1CO, MULTI42HP230V1CO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
18,000 to 42,000 BTU/h · 5 systems
No ENERGY STAR record found for these AHRI numbers
For two rooms, its GREE Comfort brochure gives heating down to −5 °F, about −21 °C. It is on neither NEEP nor the LogisVert list.
The room count on each card is the one on this page. Every size and room count is on the GREE multi-zone page.