AirGreenGREE
GREE EliteThe GREE space at AirGreen · Add-on to a furnaceGREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
Dual energy · gas and oil by a licensed partner
GREE ADD-ON · heat pump on a furnace · Updated Oct. 27, 2026

GREE add-on central heat pumps for your furnace. You keep your furnace. A GREE heat pump joins it through a cased coil, and each one heats in turn.

20 GREE cased-coil listings, from 24,000 to 60,000 BTU/h, in 3 families. A fuel-fired forced-air furnace paired with a central heat pump: that is the typical dual-energy installation according to Hydro-Québec. The heat pump heats and cools; below the Rate DT threshold, the furnace takes over.

−12 or −15 °COn Rate DT, heating switches to fuel below one of these thresholds, depending on the climate zone. A probe supplied and installed by Hydro-Québec reads the temperature.
5.131 / 30.001 ¢Rate DT price per kWh at or above the threshold, then below it, under the rates in force April 1, 2026: below the threshold, a kWh costs nearly six times as much.
$1,800 to $4,920Amounts on the Oct. 27, 2026 LogisVert list for the coil systems on this page. Whether an add-on that keeps the furnace counts as a new system is still to be confirmed with Hydro-Québec.
  • 20cased-coil listings on this page
  • 3coil families: FXA, GCAC, GCAT
  • 15.8 · 15.10 · 16our RBQ licences; gas and oil, a licensed partner
  • 4backup fuels Hydro-Québec cites: natural gas, oil, propane, pellets
AirGreen × GREEGREE Elite dealerKeep your furnaceDual energy on Rate DT5 GREE add-on installs on our blogMontréal, Laval, Longueuil, South Shore, North Shore
Dual energy on Rate DT

Who heats, and at what price? Pick your system and your threshold.

On Rate DT, the heat pump heats above the threshold and the furnace below it. The tool sets Hydro-Québec’s kWh price against the heat NEEP certifies for each coil system on this page.

Your system, your threshold

Pick the coil family, the tonnage and your climate zone’s threshold. The answer shows who heats on each side of the threshold, what a kWh costs, and the heat NEEP certifies for the heat pump at the point published at the threshold, or just above it. Your zone, −12 or −15 °C, is confirmed with Hydro-Québec: the pages we read do not give it for Montréal or Montérégie. For the R-32 systems, NEEP publishes a lower maximum at −8.3 °C than at −15 °C: we show it as published. NEEP read Oct. 26, 2026, maximum values as published; Rate DT in force April 1, 2026; LogisVert list of Oct. 27, 2026, indicative amounts.

Rate DT rules, as Hydro-Québec writes them

AloneIn fuel mode, the system’s capacity must be enough to supply the heat: the furnace heats the house without the heat pump’s help.Tarifs d’électricité, art. 2.31 a
AutomaticA switching device changes the house over from one energy source to the other, with no one stepping in.Tarifs d’électricité, art. 2.31 b
Never togetherHydro-Québec spells it out: in deep cold, the electric mode is not used at the same time as the fuel.Hydro-Québec, how Rate DT works
Over a yearHydro-Québec calls Rate DT generally cheaper than Rate D, and warns it can cost more depending on consumption habits.Hydro-Québec, Rate DT page

Hydro-Québec first asks you to have a heating contractor check that the dual-energy installation meets the requirements. Homes on natural gas: the Chauffez vert dual-energy stream, on Québec.ca, requires the home to be heated with natural gas before work starts, and gas takes over in cold weather, at −12 °C and below (page updated March 30, 2026).

Who does what

Your furnace stays. Its gas or oil side goes to a licensed partner.

An add-on touches two trades: refrigeration and fuel. Québec’s building authority, the RBQ, keeps them apart, and so do we.

WhoLicence or roleWhat they do on an add-on
AirGreenRBQ-licensed contractor
15.8 · 15.10 · 16
Ventilation, refrigeration and electricity: the outdoor unit, the cased coil, the line set and refrigerant charge, the heat pump’s electrical connection.
Licensed partnerMaster pipe-mechanic
15.2 or 15.3
The whole gas or oil side of the furnace: burner, gas valve, fuel. The RBQ reserves these subclasses for master pipe-mechanics.
Hydro-QuébecRate DT
Probe
Supplies and installs the Rate DT temperature probe, at the location and on the terms it sets.

What AirGreen does not do

We do not touch your furnace’s burner, gas valve or oil. Natural-gas burner systems (15.2) and oil burner systems (15.3) are reserved subclasses: a licensed partner does that work.

Three coil families

FXA, GCAC or GCAT: the coil decides the documents, and the figures.

All three families sit on a furnace’s air outlet, in a cabinet 445 mm (17-1/2 in) wide for 2 and 3 tons, or 622 mm (24-1/2 in) for 4 and 5 tons. What changes: the refrigerant, the distributor, and what is certified.

FamilyCertifiedWhat to know
FXAR-32 · FXU36 or FXU60 · GREE Comfort
2 of 4
The 2 and 3 tons are ENERGY STAR cold climate; the 5 tons is on NEEP, without ENERGY STAR; no certificate found for the 4 tons. The FXA page.
GCAC..NHAR-32 · Dettson documents, Wolseley network
4 of 4
All four tonnages are ENERGY STAR cold climate and on the LogisVert list. The Dettson GCAC page.
GCAC..NhAR-32 · GREE Canada documents
4 of 4
Same four AHRI numbers as the Dettson version, so the same certificates. The GREE Canada GCAC page.
GCATR-410A · GREE Canada
2 of 4
The 2 and 3 tons are ENERGY STAR cold climate; the 4 and 5 tons are on NEEP, without ENERGY STAR. On the sheets titled “FLEXX R410A cased coil”, the combination and its number are confirmed in the quote.

Certified: a NEEP record and ENERGY STAR’s cold-climate designation for the AHRI number, checked Oct. 26, 2026.

AirGreen × GREE

A furnace that stays, a GREE that joins it, and trades kept apart.

GREE designs the outdoor unit and the cased coil. AirGreen installs the heat pump, the line set and the electrical work; a licensed partner handles the gas or oil side of your furnace.

GREE

What GREE brings

  • Dual-fuel compatibleTTI, GREE Comfort and Dettson all list the R-32 FLEXX ULTRA as “Dual Fuel” compatible.
  • Three coil familiesFXA and GCAC on R-32, GCAT on R-410A, each in four tonnages.
  • One heat source at a timeThe TTI-distributed FLEXX ULTRA manual forbids the heat pump and the furnace from starting at the same time.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe look at your furnace, its air outlet and its fuel before proposing a coil.
  • 5 GREE add-on heat pumpsFew, but each one documented: articles filed under add-on on our installations blog (count as of Oct. 14, 2026).
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: a GREE heat pump that heats as long as the threshold allows, a furnace that takes over, and each trade done by the right licence holder.

The GREE shop

All 20 GREE cased-coil listings, right below.

Three families, from R-32 to R-410A. Each listing gives the outdoor unit and the coil; each family has its own page. To replace the furnace itself, see the GREE electric furnaces and GREE central systems pages.

GREE
Technician’s corner

Add-on: three things the installer checks.

The threshold, in NEEP points

NEEP publishes heat at 8.3, −8.3, −15 and −30 °C, nothing in between. In a −12 °C zone, the last certified point before the switch is −8.3 °C; in a −15 °C zone, it is the threshold itself.

NEEP · Rate DT

GCAT: two efficiency sets

GREE Canada’s UNIX brochure prints SEER2 14.3 and HSPF2 7.7 for the GCAT systems; NEEP and ENERGY STAR list 15.2 and 8.5 for the 2 and 3 tons.

GREE Canada 052024 · NEEP · ENERGY STAR

The heated base pan

Below 1 °C (33.8 °F) or during defrost, a 160 W heater warms the outdoor unit’s base pan, per NEEP, on every certified system on this page.

NEEP
Did you know?

Four things to know about the GREE add-on. Flip the cards.

LogisVert · Hydro-Québec

LogisVert and the add-on: amounts on the list, one open question.

$1,800 to $4,920The coil systems on this page that are on the list: $1,800 at 2 tons, GCAC or FXA, up to $4,920 for the 5-ton GCAC.
$0Replacing a single coil, or a single indoor or outdoor unit: excluded by guide v1.10.
No amountGCAT 4 and 5 tons and FXA 5 tons, with no ENERGY STAR record; FXA 4 tons, with no certificate found.
To confirmThe guide pays for a complete new ENERGY STAR system with an outdoor unit of at least 12,000 BTU/h. It does not say whether an add-on that keeps the furnace is one: to be confirmed with Hydro-Québec before any promise.

Hydro-Québec’s LogisVert list of Oct. 27, 2026; Hydro-Québec confirms each amount when you apply. The guide’s formula: $120 per 1,000 BTU/h at −8 °C for an ENERGY STAR cold-climate heat pump, $50 for ENERGY STAR only.

Questions

What people ask us about the GREE add-on.

What is an add-on heat pump?
A GREE outdoor unit and a cased coil set on your forced-air furnace. The heat pump heats and cools; the furnace stays as backup. Hydro-Québec cites this setup, a fuel-fired furnace paired with a central heat pump, as a typical dual-energy installation.
When does my furnace take over on Rate DT?
Below −12 °C or −15 °C depending on your climate zone: a probe supplied and installed by Hydro-Québec reads the temperature, and a switching device makes the change automatically. At or above the threshold, a kWh costs 5.131 ¢; below it, 30.001 ¢. Your address’s zone is checked with Hydro-Québec.
Does LogisVert pay for an add-on on my furnace?
Guide v1.10 pays for a complete new ENERGY STAR system and excludes replacing a single coil. The coil systems on this page are on the list from $1,800 to $4,920, but the guide does not say whether an add-on that keeps the furnace is a complete system: we have Hydro-Québec confirm it before promising an amount.
Who does the gas or oil part?
A licensed partner. Natural-gas burner systems (15.2) and oil burner systems (15.3) are RBQ subclasses reserved for master pipe-mechanics. Our licence covers ventilation (15.8), refrigeration (15.10) and electricity (16).
R-32 or R-410A on my furnace?
Both are on this page: FXA and GCAC on R-32, with a global warming potential of 675 per ENERGY STAR, and GCAT on R-410A, at 2,088. At 2 tons, NEEP gives at most 24,000 BTU/h at −15 °C for the GCAC and 21,600 for the GCAT.
My house is on natural gas: which program applies?
The Chauffez vert dual-energy stream, from the Québec government, is for homes heated with natural gas before work starts; gas takes over in cold weather, at −12 °C and below. The amounts and other conditions are on Québec.ca.
AirGreen

Keep your furnace and add a GREE? We tell you who does what before we price it.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
5 GREE add-on heat pumpsPublished with photos on our installations blog, counted on Oct. 14, 2026.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
Rate DT, April 2026Prices and rules from Hydro-Québec’s “Tarifs d’électricité” in force April 1, 2026.
Sources

Capacities and amounts: indicative, to be confirmed in the quote. Tool answers: AirGreen, from the published values above. Page updated Oct. 26, 2026; NEEP and ENERGY STAR records checked again that day, LogisVert list dated Oct. 27, 2026.