GREE add-on central heat pumps for your furnace. You keep your furnace. A GREE heat pump joins it through a cased coil, and each one heats in turn.
20 GREE cased-coil listings, from 24,000 to 60,000 BTU/h, in 3 families. A fuel-fired forced-air furnace paired with a central heat pump: that is the typical dual-energy installation according to Hydro-Québec. The heat pump heats and cools; below the Rate DT threshold, the furnace takes over.
- 20cased-coil listings on this page
- 3coil families: FXA, GCAC, GCAT
- 15.8 · 15.10 · 16our RBQ licences; gas and oil, a licensed partner
- 4backup fuels Hydro-Québec cites: natural gas, oil, propane, pellets
Who heats, and at what price? Pick your system and your threshold.
On Rate DT, the heat pump heats above the threshold and the furnace below it. The tool sets Hydro-Québec’s kWh price against the heat NEEP certifies for each coil system on this page.
Your system, your threshold
Pick the coil family, the tonnage and your climate zone’s threshold. The answer shows who heats on each side of the threshold, what a kWh costs, and the heat NEEP certifies for the heat pump at the point published at the threshold, or just above it. Your zone, −12 or −15 °C, is confirmed with Hydro-Québec: the pages we read do not give it for Montréal or Montérégie. For the R-32 systems, NEEP publishes a lower maximum at −8.3 °C than at −15 °C: we show it as published. NEEP read Oct. 26, 2026, maximum values as published; Rate DT in force April 1, 2026; LogisVert list of Oct. 27, 2026, indicative amounts.
Rate DT rules, as Hydro-Québec writes them
Hydro-Québec first asks you to have a heating contractor check that the dual-energy installation meets the requirements. Homes on natural gas: the Chauffez vert dual-energy stream, on Québec.ca, requires the home to be heated with natural gas before work starts, and gas takes over in cold weather, at −12 °C and below (page updated March 30, 2026).
Your furnace stays. Its gas or oil side goes to a licensed partner.
An add-on touches two trades: refrigeration and fuel. Québec’s building authority, the RBQ, keeps them apart, and so do we.
What AirGreen does not do
We do not touch your furnace’s burner, gas valve or oil. Natural-gas burner systems (15.2) and oil burner systems (15.3) are reserved subclasses: a licensed partner does that work.
FXA, GCAC or GCAT: the coil decides the documents, and the figures.
All three families sit on a furnace’s air outlet, in a cabinet 445 mm (17-1/2 in) wide for 2 and 3 tons, or 622 mm (24-1/2 in) for 4 and 5 tons. What changes: the refrigerant, the distributor, and what is certified.
Certified: a NEEP record and ENERGY STAR’s cold-climate designation for the AHRI number, checked Oct. 26, 2026.
A furnace that stays, a GREE that joins it, and trades kept apart.
GREE designs the outdoor unit and the cased coil. AirGreen installs the heat pump, the line set and the electrical work; a licensed partner handles the gas or oil side of your furnace.
What GREE brings
- Dual-fuel compatibleTTI, GREE Comfort and Dettson all list the R-32 FLEXX ULTRA as “Dual Fuel” compatible.
- Three coil familiesFXA and GCAC on R-32, GCAT on R-410A, each in four tonnages.
- One heat source at a timeThe TTI-distributed FLEXX ULTRA manual forbids the heat pump and the furnace from starting at the same time.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateWe look at your furnace, its air outlet and its fuel before proposing a coil.
- 5 GREE add-on heat pumpsFew, but each one documented: articles filed under add-on on our installations blog (count as of Oct. 14, 2026).
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: a GREE heat pump that heats as long as the threshold allows, a furnace that takes over, and each trade done by the right licence holder.
All 20 GREE cased-coil listings, right below.
Three families, from R-32 to R-410A. Each listing gives the outdoor unit and the coil; each family has its own page. To replace the furnace itself, see the GREE electric furnaces and GREE central systems pages.
Add-on: three things the installer checks.
The threshold, in NEEP points
NEEP publishes heat at 8.3, −8.3, −15 and −30 °C, nothing in between. In a −12 °C zone, the last certified point before the switch is −8.3 °C; in a −15 °C zone, it is the threshold itself.
NEEP · Rate DTGCAT: two efficiency sets
GREE Canada’s UNIX brochure prints SEER2 14.3 and HSPF2 7.7 for the GCAT systems; NEEP and ENERGY STAR list 15.2 and 8.5 for the 2 and 3 tons.
GREE Canada 052024 · NEEP · ENERGY STARThe heated base pan
Below 1 °C (33.8 °F) or during defrost, a 160 W heater warms the outdoor unit’s base pan, per NEEP, on every certified system on this page.
NEEPFour things to know about the GREE add-on. Flip the cards.
LogisVert and the add-on: amounts on the list, one open question.
Hydro-Québec’s LogisVert list of Oct. 27, 2026; Hydro-Québec confirms each amount when you apply. The guide’s formula: $120 per 1,000 BTU/h at −8 °C for an ENERGY STAR cold-climate heat pump, $50 for ENERGY STAR only.
What people ask us about the GREE add-on.
What is an add-on heat pump?
When does my furnace take over on Rate DT?
Does LogisVert pay for an add-on on my furnace?
Who does the gas or oil part?
R-32 or R-410A on my furnace?
My house is on natural gas: which program applies?
Keep your furnace and add a GREE? We tell you who does what before we price it.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- AirGreen GREE page: Elite status and installations, facts checked Oct. 5, 2026; GREE installation count of Oct. 14, 2026
- Hydro-Québec, “Tarifs d’électricité”, in force April 1, 2026, section 5 (Rate DT), articles 2.31 and 2.34
- Hydro-Québec, “Tarif DT” and “Fonctionnement du tarif DT” pages, read Oct. 26, 2026
- Québec.ca, Chauffez vert, dual-energy conversion (electricity and natural gas), page updated March 30, 2026, read Oct. 26, 2026
- Régie du bâtiment du Québec, licence subclass list, document 1592(2025-10)
- TTI Climatisation, French GREE FLEXX ULTRA outdoor unit manual, read Oct. 26, 2026
- FLEXX ULTRA R32 brochures from TTI (BRO0125), GREE Comfort and Dettson: “Dual-Fuel” and “add-on” wording
- GREE Canada, UNIX R410A central system brochure, document No. 052024, read Oct. 26, 2026
- GREE Canada, “UNIX R32 central system” brochure, document No. 062025, page 3 (cased coil)
Capacities and amounts: indicative, to be confirmed in the quote. Tool answers: AirGreen, from the published values above. Page updated Oct. 26, 2026; NEEP and ENERGY STAR records checked again that day, LogisVert list dated Oct. 27, 2026.