GREE FLEXX ULTRA R32 heat pump on a furnace, FXA coil. Which outdoor unit goes with which coil, and which figures are actually certified: one document at a time.

4 R-32 FLEXX ULTRA systems on an FXA coil, from 24,000 to 60,000 BTU/h. The FXA sits on your furnace; GREE Comfort publishes its brochure, submittals and service manual. These documents do not always say the same thing as NEEP: we show you both.

FXU36 · FXU60Two outdoor units for four coils: the FXU36 for the FXA24 and FXA36, the FXU60 for the FXA48 and FXA60, per GREE Comfort’s brochure.
26,000 BTU/hAt −8.3 °C for the 3-ton system (FXU36 + FXA36), per NEEP and ENERGY STAR. GREE Comfort’s brochure prints 22,000: the certified figure sets LogisVert, $3,120.
2 inMinimum distance between the FXA drain pan and a standard gas-fired furnace heat exchanger, per GREE Comfort’s submittals.
  • 4FXA coil systems on this page
  • 2 of 4tonnages ENERGY STAR cold climate: 2 and 3 tons
  • EAleak code: fan forced on, gas valve shut
  • 31 ftof line set pre-charged at the factory, coil system
AirGreen × GREEGREE Elite dealerFLEXX ULTRA R32 on your furnaceFXA coil, 2 to 5 tonsEach document against the certificateMontréal, Laval, Longueuil, South Shore, North Shore
One coil, several documents

Pick your FXA: what GREE Comfort prints, what the lists certify.

For each coil, the brochure, the submittal and the certification lists give their own version. When they differ, LogisVert follows ENERGY STAR; so do we.

One coil, two versions of the facts

Pick your FXA. On the left, what GREE Comfort prints in its brochure and submittals; on the right, what NEEP, ENERGY STAR and Hydro-Québec hold for the same pair. In bold, what differs.

All four FXA coils at a glance

FXA24FXA36FXA48FXA60
Outdoor unitFXU36FXU36FXU60FXU60
NEEP certificate217177255217177256to be checked217177258
ENERGY STAR cold climateyesyes—no
LogisVert$1,800$3,120——

Pairs per GREE Comfort’s brochure. NEEP certifies the 2-, 3- and 5-ton pairs; the 4-ton pair could not be checked with NEEP. Your system’s pair is confirmed in the quote. LogisVert list of Oct. 27, 2026, indicative amounts.

The FXA and your furnace

What the coil asks of the furnace, and what it tells it to do.

The FXA is not just a coil sitting on the furnace: it has its own board, leak sensor and electronic expansion valve. Here is what GREE Comfort’s service manual and submittals require.

  1. 2 in from the heat exchangerThe drain pan must be at least 2 in from a standard gas-fired furnace heat exchanger.
  2. 24 V from the furnaceThe coil board takes its 24 V AC from the furnace’s R terminal and sends back the W1out and W2out gas-valve signals.
  3. Leak: code EAIf the sensor detects a leak, the board shows EA, sounds an alarm, forces the fan on and shuts off the outdoor unit and the furnace gas valve.
  4. DownflowMove the secondary drain pan and reposition the air inlet and outlet sensors: the FXA then installs counter-flow.
  5. 25 in in frontAt least 25 in of clearance in front of the coil for service.

The gas side, by a licensed partner

The W1out and W2out signals drive the gas valve. Connecting to a gas furnace is done with a licensed partner: the burner, the valve and the fuel are theirs. AirGreen installs the heat pump, the coil, the line set and the electrical work, under its RBQ licences 15.8, 15.10 and 16.

AirGreen × GREE

An FXU outside, an FXA on the furnace, and each connection to the right licence holder.

GREE designs the FLEXX ULTRA and its FXA coil; GREE Comfort publishes its documents. AirGreen picks the right pair, installs the coil and line set, and leaves the furnace’s gas side to a licensed partner.

GREE

What GREE brings

  • An expansion valve in the coilThe FXA has its own electronic expansion valve; per the TTI-distributed manual, the FXU outdoor unit has no TXV.
  • SEER2 up to 16.0Per the brochure, for the FXA24 and FXA36; 15.2 for the FXA48 and FXA60.
  • A named thermostatThe service manual names the WK-010WC1 for all the coil systems’ functions.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe check the FXU and FXA pair, then the room between the pan and the furnace heat exchanger.
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: an FXA on the right FXU, under the right certificate, set at the right distance from the furnace heat exchanger, and the gas side done by the right licence holder.

The GREE shop

All 4 FLEXX ULTRA systems on an FXA coil, right below.

Each listing gives the FXU and FXA pair. The same FLEXX ULTRA on an air handler is on the FLEXX ULTRA R32 page; the other coils, on the ADD-ON page.

GREE
Technician’s corner

FXA coil: GREE Comfort’s values, size by size.

GREE ComfortFXA24FXA36FXA48FXA60
Cabinet, W x H x D17-1/2 × 23 × 21-1/4 in17-1/2 × 23 × 21-1/4 in24-1/2 × 28-1/2 × 21-1/4 in24-1/2 × 28-1/2 × 21-1/4 in
Net / gross weight75 / 83.8 lb75 / 83.8 lb110.0 / 123.5 lb110.0 / 123.5 lb
Dehumidification5.11 pt/h7.75 pt/h11.77 pt/h13.11 pt/h
SEER2 / EER216.0 / 11.016.0 / 11.015.2 / 10.015.2 / 9.5
HSPF28.58.58.58.5
Outdoor sound61 dB(A)61 dB(A)63 dB(A)63 dB(A)
Outdoor MCA / MOCP27.7 / 30 A27.7 / 30 A39.9 / 45 A39.9 / 45 A
R-32 charge102.3 oz102.3 oz162.3 oz162.3 oz

GREE Comfort brochure GREE_FLEXX_ULTRA_R32_A-COIL_012926 and submittals. Drain printed “Φ1×0.05” in for every size. GREE Comfort does not publish the sound measuring distance.

Did you know?

Four things to know about the FXA. Flip the cards.

LogisVert · Hydro-Québec

LogisVert and the FXA: two tonnages on the list.

$1,800FXU36 + FXA24 (217177255): 15,000 BTU/h at −8.3 °C per ENERGY STAR, at $120 per 1,000 BTU/h.
$3,120FXU36 + FXA36 (217177256): 26,000 BTU/h at −8.3 °C, ENERGY STAR’s value, not the brochure’s 22,000.
No amountFXA48 (217177257 per GREE Comfort) and FXA60 (217177258): no ENERGY STAR record, so not on the list.
To confirmAn FXA set on the furnace you keep: guide v1.10 does not settle whether it makes a complete new system.

Amounts listed on Oct. 27, 2026 for the FXU and FXA pairs; indicative, Hydro-Québec confirms them when you apply.

Questions

What people ask us about the FXA coil.

Which outdoor unit goes with my FXA coil?
Per GREE Comfort, the FXA24C32AH and FXA36C32AH go on the FXU36HP230V1R32AO, the FXA48C32AH and FXA60C32AH on the FXU60HP230V1R32AO. NEEP certifies the 2-, 3- and 5-ton pairs, under 217177255, 217177256 and 217177258.
Does the 5-ton FXA system qualify for LogisVert?
Not per the Oct. 27, 2026 list: NEEP records it without ENERGY STAR, and ENERGY STAR has no FXA60 record on the FXU60. The 3-ton (217177256) is listed at $3,120, the 2-ton (217177255) at $1,800.
What does the coil do to my gas furnace if refrigerant leaks?
It shows EA, sounds an alarm, forces the fan on and shuts off the outdoor unit and the furnace gas valve. Connecting to a gas furnace is done with a licensed partner.
What is the 4-ton system’s AHRI number?
GREE Comfort’s submittal prints 217177257 for FXA48C32AH + FXU60HP230V1R32AO. We found it neither on ENERGY STAR nor on the LogisVert list, and could not check it with NEEP: so we quote neither a certified figure nor an amount for this tonnage.
Can the coil go on a downflow furnace?
Yes, per GREE Comfort’s service manual, once the secondary drain pan is moved and the air inlet and outlet sensors are repositioned.
Which warranty applies to the FXA?
GREE Comfort, in the United States, prints 5 years on parts and 7 years on the compressor for its coil systems. TTI’s FLEXX ULTRA brochure prints 10 years, but for its air-handler systems. Your FXA system’s terms are set out in the quote.
AirGreen

An FXA on your furnace? We check the pair, the certificate and the distance to the heat exchanger.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
Certificate firstWhen a GREE Comfort document differs from NEEP or ENERGY STAR, this page shows both.