GREE FLEXX ULTRA R32 heat pump on a furnace, FXA coil. Which outdoor unit goes with which coil, and which figures are actually certified: one document at a time.
4 R-32 FLEXX ULTRA systems on an FXA coil, from 24,000 to 60,000 BTU/h. The FXA sits on your furnace; GREE Comfort publishes its brochure, submittals and service manual. These documents do not always say the same thing as NEEP: we show you both.
- 4FXA coil systems on this page
- 2 of 4tonnages ENERGY STAR cold climate: 2 and 3 tons
- EAleak code: fan forced on, gas valve shut
- 31 ftof line set pre-charged at the factory, coil system
Pick your FXA: what GREE Comfort prints, what the lists certify.
For each coil, the brochure, the submittal and the certification lists give their own version. When they differ, LogisVert follows ENERGY STAR; so do we.
One coil, two versions of the facts
Pick your FXA. On the left, what GREE Comfort prints in its brochure and submittals; on the right, what NEEP, ENERGY STAR and Hydro-Québec hold for the same pair. In bold, what differs.
All four FXA coils at a glance
| FXA24 | FXA36 | FXA48 | FXA60 | |
|---|---|---|---|---|
| Outdoor unit | FXU36 | FXU36 | FXU60 | FXU60 |
| NEEP certificate | 217177255 | 217177256 | to be checked | 217177258 |
| ENERGY STAR cold climate | yes | yes | — | no |
| LogisVert | $1,800 | $3,120 | — | — |
Pairs per GREE Comfort’s brochure. NEEP certifies the 2-, 3- and 5-ton pairs; the 4-ton pair could not be checked with NEEP. Your system’s pair is confirmed in the quote. LogisVert list of Oct. 27, 2026, indicative amounts.
What the coil asks of the furnace, and what it tells it to do.
The FXA is not just a coil sitting on the furnace: it has its own board, leak sensor and electronic expansion valve. Here is what GREE Comfort’s service manual and submittals require.
- 2 in from the heat exchangerThe drain pan must be at least 2 in from a standard gas-fired furnace heat exchanger.
- 24 V from the furnaceThe coil board takes its 24 V AC from the furnace’s R terminal and sends back the W1out and W2out gas-valve signals.
- Leak: code EAIf the sensor detects a leak, the board shows EA, sounds an alarm, forces the fan on and shuts off the outdoor unit and the furnace gas valve.
- DownflowMove the secondary drain pan and reposition the air inlet and outlet sensors: the FXA then installs counter-flow.
- 25 in in frontAt least 25 in of clearance in front of the coil for service.
The gas side, by a licensed partner
The W1out and W2out signals drive the gas valve. Connecting to a gas furnace is done with a licensed partner: the burner, the valve and the fuel are theirs. AirGreen installs the heat pump, the coil, the line set and the electrical work, under its RBQ licences 15.8, 15.10 and 16.
An FXU outside, an FXA on the furnace, and each connection to the right licence holder.
GREE designs the FLEXX ULTRA and its FXA coil; GREE Comfort publishes its documents. AirGreen picks the right pair, installs the coil and line set, and leaves the furnace’s gas side to a licensed partner.
What GREE brings
- An expansion valve in the coilThe FXA has its own electronic expansion valve; per the TTI-distributed manual, the FXU outdoor unit has no TXV.
- SEER2 up to 16.0Per the brochure, for the FXA24 and FXA36; 15.2 for the FXA48 and FXA60.
- A named thermostatThe service manual names the WK-010WC1 for all the coil systems’ functions.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateWe check the FXU and FXA pair, then the room between the pan and the furnace heat exchanger.
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: an FXA on the right FXU, under the right certificate, set at the right distance from the furnace heat exchanger, and the gas side done by the right licence holder.
All 4 FLEXX ULTRA systems on an FXA coil, right below.
Each listing gives the FXU and FXA pair. The same FLEXX ULTRA on an air handler is on the FLEXX ULTRA R32 page; the other coils, on the ADD-ON page.
FXA coil: GREE Comfort’s values, size by size.
| GREE Comfort | FXA24 | FXA36 | FXA48 | FXA60 |
|---|---|---|---|---|
| Cabinet, W x H x D | 17-1/2 × 23 × 21-1/4 in | 17-1/2 × 23 × 21-1/4 in | 24-1/2 × 28-1/2 × 21-1/4 in | 24-1/2 × 28-1/2 × 21-1/4 in |
| Net / gross weight | 75 / 83.8 lb | 75 / 83.8 lb | 110.0 / 123.5 lb | 110.0 / 123.5 lb |
| Dehumidification | 5.11 pt/h | 7.75 pt/h | 11.77 pt/h | 13.11 pt/h |
| SEER2 / EER2 | 16.0 / 11.0 | 16.0 / 11.0 | 15.2 / 10.0 | 15.2 / 9.5 |
| HSPF2 | 8.5 | 8.5 | 8.5 | 8.5 |
| Outdoor sound | 61 dB(A) | 61 dB(A) | 63 dB(A) | 63 dB(A) |
| Outdoor MCA / MOCP | 27.7 / 30 A | 27.7 / 30 A | 39.9 / 45 A | 39.9 / 45 A |
| R-32 charge | 102.3 oz | 102.3 oz | 162.3 oz | 162.3 oz |
GREE Comfort brochure GREE_FLEXX_ULTRA_R32_A-COIL_012926 and submittals. Drain printed “Φ1×0.05” in for every size. GREE Comfort does not publish the sound measuring distance.
Four things to know about the FXA. Flip the cards.
LogisVert and the FXA: two tonnages on the list.
Amounts listed on Oct. 27, 2026 for the FXU and FXA pairs; indicative, Hydro-Québec confirms them when you apply.
What people ask us about the FXA coil.
Which outdoor unit goes with my FXA coil?
Does the 5-ton FXA system qualify for LogisVert?
What does the coil do to my gas furnace if refrigerant leaks?
What is the 4-ton system’s AHRI number?
Can the coil go on a downflow furnace?
Which warranty applies to the FXA?
An FXA on your furnace? We check the pair, the certificate and the distance to the heat exchanger.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- GREE Comfort (USA), FLEXX ULTRA R32 A-coil brochure, GREE_FLEXX_ULTRA_R32_A-COIL_012926, read Oct. 26, 2026
- GREE Comfort (USA), FXA coil submittals, 24, 36, 48 and 60 MBH (…_SUB_08272025), read Oct. 26, 2026
- GREE Comfort (USA), coil service manual, CAT NO GREE_FLEXX_R32_SERVICE_MANUAL_102725, read Oct. 26, 2026
- TTI Climatisation, French GREE FLEXX ULTRA outdoor unit manual, read Oct. 26, 2026
- TTI Climatisation, French GREE FLEXX ULTRA R32 brochure, GREE_FLEXX_ULTRA_R32_BRO0125
Capacities and amounts: indicative, to be confirmed in the quote. Tool answers: AirGreen, from the published values above. Page updated Oct. 26, 2026; NEEP and ENERGY STAR records checked again that day, LogisVert list dated Oct. 27, 2026.