One card per line, computed from its five-room systems: coldest point catalogued by NEEP, maximum capacities, ENERGY STAR designation and LogisVert amount, then what GREE documents for five units.
R-32Current generation
Free Match M R32 (FreeMatch R32)
GWHD(42)ND6MO
- −30 °Clowest point catalogued by NEEP
- 37,800max. BTU/h at −15 °C (NEEP)
- 44,500max. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
ENERGY STAR cold climate for every system
LogisVert up to $5,340 indicative
The only size of the line offered here that takes five rooms, and the only 42,000 with a GREE Canada figure for every room: 19 combinations, with indoor units from 5,000 to 24,000.
R-32Current generation
MULTI R32
MUL42HP230V1R32AO
- −30 °Clowest point catalogued by NEEP
- 37,800max. BTU/h at −15 °C (NEEP)
- 44,500max. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
ENERGY STAR cold climate for every system
LogisVert up to $5,340 indicative
Its 42,000 submittal gives 8,400 BTU/h per room for five 9,000 units as for five 12,000s: the figures of GREE Canada’s table.
R-410APrevious generation · while stocks last
Free Match M Series
GWHD(42)ND3MO
- −30 °Clowest point catalogued by NEEP
- 32,400max. BTU/h at −15 °C (NEEP)
- 38,200max. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
ENERGY STAR cold climate for every system
LogisVert up to $4,272 indicative
Five rooms on the 42,000, on R-410A. NEEP gives it 32,400 BTU/h at −15 °C for the whole system, 5,400 less than the Free Match M R32 of the same size.
R-410APrevious generation · while stocks last
Multi GEN2
MULTI42HP230V1EO
- −30 °Clowest point catalogued by NEEP
- 32,400max. BTU/h at −15 °C (NEEP)
- 38,200max. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
ENERGY STAR, without the cold-climate designation
LogisVert up to $1,780 indicative
13 five-unit combinations in GREE Comfort’s catalog, without per-room heat. ENERGY STAR does not give it the cold-climate designation: $1,780 from LogisVert.
R-410APrevious generation · while stocks last
Free Match Extreme
GWHD(42)ND3J/O
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
No ENERGY STAR record found for these AHRI numbers
GREE Canada allows it 2 to 5 units on the 42,000, with no public combination table. Off NEEP and ENERGY STAR since October 2026: no LogisVert amount.
R-410APrevious generation · while stocks last
Multi+ Ultra
MULTIU42HP230V1DO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
42,000 BTU/h · 1 system
No ENERGY STAR record found for these AHRI numbers
The same 13 five-unit combinations as the Multi GEN2 in GREE Comfort’s catalog. NEEP has not listed it since October 2026: no certified cold figures any more.
R-410APrevious generation · while stocks last
Free Match (first generation)
GWHD(36)ND3GO, GWHD(42)ND3EO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
36,000 to 42,000 BTU/h · 2 systems
No ENERGY STAR record found for these AHRI numbers
Offered here at 36,000 and 42,000 for five rooms, with no public GREE document or NEEP record: nothing outside our product sheets confirms the room count.
R-410APrevious generation · while stocks last
Multi21+
MULTI36HP230V1CO, MULTI42HP230V1CO
- nonelowest point catalogued by NEEP
- nonemax. BTU/h at −15 °C (NEEP)
- nonemax. BTU/h at −8 °C (NEEP)
36,000 to 42,000 BTU/h · 2 systems
No ENERGY STAR record found for these AHRI numbers
The only 36,000 that takes five rooms per GREE Comfort (“1 - 5”), with just two combinations: 9 + 9 + 9 + 9 + 9 and 9 + 9 + 9 + 9 + 12.
Eight of the ten systems on this page are 42,000s; of the two 36,000s, only the Multi21+ has a GREE document that allows five units. The other room counts: GREE multi-zone page.