GREE Free Match M Series heat pumps, 5 rooms. Only one M Series takes five units: the GWHD(42)ND3MO. Do your five line sets and your heights fit its limits?
One M Series five-room system: the 42,000, on R-410A. Bedrooms, living area, basement or office on a single outdoor unit. Before heat and price, the question is physical: five line sets and two heights have to fit GREE Canada’s limits.
- 1system on this page
- 208786088non-ducted AHRI number, on the product sheet
- 1/1ENERGY STAR cold climate, AHRI 208786088
- R-410A3.8 kg from the factory; sold while stocks last
Five line sets on a GWHD(42)ND3MO: do they fit?
Five lengths, two heights: the test checks them against the limits GREE Canada publishes for the 42,000, then against the length Dettson pre-charges at the factory.
Your measurements against the 42,000’s limits
Enter the line-set length to each room, then the two heights, measured or estimated. Each line passes or not; the last one says whether the pre-charge is enough.
The same outdoor unit, two AHRI numbers, two amounts.
With ducted units everywhere, the 42,000 is rated 32,400 BTU/h at −8.3 °C instead of 35,600; at −15 °C, both configurations give the same heat. It is the LogisVert amount that moves.
Ducted or not: the AHRI number changes
Hydro-Québec pays according to the system’s AHRI number. For the 42,000, GREE Canada prints two. Pick the type of your five indoor units.
NEEP and ENERGY STAR read Oct. 26, 2026; Hydro-Québec, list dated Oct. 27, 2026; AHRI numbers: GREE Canada, document 062024 (“without / with duct”).
Fewer than five rooms? The other M Series pages, or every five-zone GREE line, R-32 included:
Five rooms on a 42,000: we measure everything before proposing it.
Only one M Series size goes up to five units; what remains is checking that your house fits it. AirGreen surveys the five line sets and the heights, calculates each room’s heat and checks the configuration’s AHRI number.
What GREE brings
- Five zones on one unitGREE Canada describes the M Series as powering up to five indoor units with one outdoor unit.
- One circuitFor the whole system, five units included, GREE Canada prints a 29 A MCA and a 45 A maximum protection.
- Common line sizesSuction 9.52 mm (3/8 in) and liquid 6.35 mm (1/4 in), per GREE Canada.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateBefore the quote: five lengths measured, two heights, and the right AHRI number for Hydro-Québec.
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: five rooms on a single M Series outdoor unit, within GREE Canada’s limits, installed by a GREE Elite dealer.
The five-room GWHD(42)ND3MO, for sale right below.
The product sheet gives the non-ducted AHRI number, 208786088. With ducted units everywhere, the number and the amount change: see above.
In deep cold: the heat the 42,000 keeps.
Line sets are checked at the top of the page; here, NEEP-certified heat, from 8.3 °C to −30 °C.
The heat the five rooms share, from 8.3 °C to −30 °C.
The bars show the capacities NEEP publishes for AHRI 208786088, for the whole system. The full record, minimum and power input included, follows the tools.
The GREE multi-zone page explains the design temperature used for Montréal.
The 42,000 at every published temperature: minimum, rated, maximum.
These are the figures the electrician and the installer ask for: heat, COP and what the unit draws from the circuit at each point.
| Outdoor temperature | Minimum | Rated | Maximum | COP rated · max. | Power input |
|---|---|---|---|---|---|
| Heating at 8.3 °C (47 °F) | 8,870 | 40,000 | 43,200 | 3.88 · 3.17 | 3.02 kW · 3.99 kW |
| Heating at −8.3 °C (17 °F) | 9,000 | 35,600 | 38,200 | 2.38 · 2.30 | 4.38 kW · 4.87 kW |
| Heating at −15 °C (5 °F) | 9,000 | 32,400 | 32,400 | 1.92 · 1.92 | 4.95 kW |
| Heating at −30 °C (−22 °F) | 8,000 | — | 24,500 | — · 1.50 | — · 4.79 kW |
| Cooling at 35 °C (95 °F) | 8,870 | 36,000 | 40,940 | — | — |
NEEP, AHRI 208786088 (“Multizone All Non-Ducted”), read Oct. 26, 2026; capacities in BTU/h for the whole system, power at rated · at maximum. NEEP also records 81% capacity maintenance at −15 °C and a 96 W base-pan heater.
For the circuit rating, the unit’s nameplate prevails, not the power input.
The 42,000 on the job.
The cabinet
Cabinet 1020 × 826 × 427 mm; 79.0 kg net, 86.0 kg packed. Airflow 5800 m³/h (3413 CFM), 63 dB(A) printed without a measuring distance.
GREE Canada 062024The charge
3.8 kg of R-410A from the factory, the largest M Series charge, pre-charged for 40 m of line set per Dettson. Beyond that, the amount per metre is published by neither GREE Canada nor Dettson.
GREE Canada 062024 · Dettson X61019The operating ranges
Heating from −30 to 24 °C per GREE Canada and Dettson. In cooling, the two documents disagree for the same units: −18 to 48 °C at GREE Canada, −30 to 48 °C at Dettson.
GREE Canada 062024 · Dettson X61019The 42,000 in six cards. Flip them.
Five rooms, one amount: $4,272 or $3,888.
Indicative amounts from the list dated Oct. 27, 2026: Hydro-Québec caps them at the pre-tax cost and confirms them when you apply. LogisVert pays for the system, not for each room; for a mix of ducted and wall units, the AHRI number is confirmed before you apply. Nothing to add on the federal side: the Canada Greener Homes Grant ($2,500 / $5,000) is closed, deadline Sept. 30, 2025.
Five rooms on the 42,000: the questions before you sign.
Which M Series system takes five rooms?
Is there enough heat for five rooms in January?
How do five line sets fit the limits?
Does five rooms change the LogisVert amount?
The brochure says “ENERGY STAR: NO”. Is it certified?
For five rooms, the M Series or the Free Match M R32?
Five rooms on one unit: we measure the five line sets before proposing the 42,000.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- GREE Canada, Free Match M Series brochure (R-410A), document Rev. A 062024, English and French versions
- Dettson, Free Match M Series sheet, document X61019_C (Wolseley network)
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- Natural Resources Canada, Canada Greener Homes Grant (Québec): program closed, applications until Sept. 30, 2025, read Oct. 26, 2026
- National Building Code of Canada 2020, Appendix C, Table C-2 (Montréal, City Hall)
- AirGreen GREE page: Elite status and installations, facts checked Oct. 5, 2026; GREE installation count of Oct. 14, 2026
Capacities and amounts: indicative, to be confirmed in the quote. Tool calculations: AirGreen, from the published values above. Page updated Oct. 27, 2026; NEEP records, ENERGY STAR and the LogisVert list checked again that day.