AirGreenGREE
GREE EliteThe GREE space at AirGreen · ThermostatsGREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
Original GREE controllers
GREE · thermostats and wall controllers · Updated Oct. 27, 2026

GREE thermostats and wall controllers. Nine controls, and not one that fits everything. Which one does GREE name for yours, and how far can the cable run?

9 GREE controls on this page, from a wall unit’s controller to a building’s. The right controller depends on the system: a wall unit, a cassette, a duct or a GMV do not take the same ones. And the cable rule changes depending on whether the document is American or Canadian.

20 mBetween the indoor unit’s board and the controller, per the Canadian XE72-44/E and XE71-44/G manuals; 8 m as standard. GREE Comfort’s US documents stop at 26 ft (7.9 m).
16Indoor units at most on a single XK46, one of the two GMV controllers on this page, per its manual published by GREE Canada.
8 segmentsA day, on the XK76’s 7-day schedule. It is the wall controller Dettson lists as optional for the Freematch R32.
  • 9GREE controls on this page
  • 14system-to-controller pairings, each with its document
  • ME34-44/Gthe adapter that keeps your 24 V thermostat
  • GREE+the app that runs the XE72-44/E
AirGreen × GREEGREE Elite dealerThe right controller for the right systemXK76 · XE72-44/E · XK46 · ME34-44/GOne document per pairingMontréal, Laval, Longueuil, South Shore, North Shore
The right controller

Pick your system. GREE says which one goes with it.

Fourteen pairings taken from GREE Canada brochures, Dettson drawings, manuals and GREE Comfort submittals. US series model numbers do not match Canadian ones: they are listed separately, last.

Which controller for which system?

Each answer gives the controller, whether it is included or optional, the cable rule and the document. Systems sold in Canada come first; US series are marked “USA”.

All nine side by side

What each control does, and the document that says so.

Eight wall controllers and one adapter. GREE Comfort’s US sheets and the Canadian manuals do not always agree; where they differ, both values are shown.

Control and systems namedWhat it doesCableDocuments
XK76
Single-zone walls (USA); Free Match R32 and All Match R32 8-way cassette (Dettson)
7 days, 8 segments a day; freeze guard above 46 °F (about 7.8 °C)26 ft at mostXK76 submittal; Dettson X60063D and X60069-2A
XK19
Cassettes, ducts, floor/ceiling, mini consoles (USA); Free Match Extreme cassette and slim duct
Wired “Command Center” for ductless split systems, per GREE ComfortIncluded, 26 ft (7.9 m), no cutting or splicingXK19 submittal; Extreme brochure 062024
XE72-44/E
All Match R32 high-static ducts (included); one-way and 8-way cassettes (optional)
GREE+ app; away function in heating only, 46 °F (8 °C) setpoint20 m at most, 8 m as standardDettson manual X40274A; brochures 062025; Dettson X60069-2A
ME34-44/G
GREE wall, cassette, duct, floor-ceiling units
Connects a 24 VAC thermostat; 135 × 36 × 164 mm boxH1/H2 to the unit, RS485ME34-44/G submittal; GREE Canada Unity Controller page
XE70-33/H
GMV (VRF)
7 days, up to 4 schedules; capacitive touch screen; included with the GMV multi-position air handler—XE70-33/H submittal; GREE Comfort catalogue
XK60
U-Match (USA)
Programmable; sets static pressure on UMAT BD units18-2 AWG supplied on site, 26 ft at mostXK60 submittal; compatibility guide
XK46
GMV (VRF)
Up to 16 units; 16 to 30 °C setpoint; Floor Heating, 3D Heating and Space Heating modesLine of 250 m in totalGREE Canada XK46 manual; GREE Comfort submittal
XK41
Terra, Vireo, Vireo+, Neo, Livo, Livo+, Sapphire single-zone walls (USA)
Wired control for single-zone wall units, 115 V or 230 V alike26 ft at mostXK41 submittal
XE71
Livo, Vireo, Vireo ULTRA, Sapphire, Multi DUCT, CAS, FLR (USA); Free Match M Series VITA wall unit and cassette
Built-in RF receiver26 ft (GREE Comfort) or 20 m, 8 m as standard (XE71-44/G manual)XE71 submittal; manual published by TTI; Free Match M brochure

“26 ft”: maximum harness length for all wired controllers per GREE Comfort’s compatibility guide. “USA”: US series, whose model numbers are not the ones sold in Canada. No warranty is published for these controls in the documents read on Oct. 26, 2026.

AirGreen × GREE

The GREE controller, wired by the people who install the system.

GREE designs each controller for specific units. AirGreen reads the model number, picks the control GREE names and runs the cable within the document’s limits.

GREE

What GREE brings

  • One control per familyFrom the wall units’ XK76 to the GMV systems’ XK46, each controller has its units named by GREE.
  • Your 24 V thermostat, keptThe ME34-44/G adapter connects a 24 VAC thermostat to ductless GREE units.
  • A bilingual manual for the adapterGREE Canada publishes the ME34-44/G owner’s manual in French and English, on its Unity Controller page.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe read your unit’s model number and tell you which controller GREE names for it.
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: the controller GREE names for your system, wired within its document’s cable limits, by a GREE Elite dealer.

The GREE shop

All 9 GREE controls, right below.

Each product page carries the controller’s name. To know which one fits your unit, use the tool at the top; for their differences, the table of all nine.

GREE
Technician’s corner

Static pressure, the Extreme brochure, the terminals: what the installer checks.

The XE71 and static pressure

The XE71 submittal says it cannot set static pressure on DUCT B ducts and points to the XK76 or XK19. GREE Comfort’s compatibility guide has a note on the controllers that can, without it being readable which ones. We follow the XE71 submittal.

XE71 submittal · compatibility guide, note 2

The Extreme wall unit

For its wired thermostat, GREE Canada’s 062024 brochure prints XE-41 in the English version and XE-71 (optional) in the French one. Same document, two answers: the unit’s model number decides.

GREE Canada, Free Match Extreme brochure 062024

The ME34-44/G, terminal by terminal

O/B for the reversing valve, G for the fan, W for heating or the electric element, Y for the compressor, G1 to G3 for three fan speeds. If the thermostat also runs a gas or oil furnace, that side goes to a licensed partner.

ME34-44/G submittal, GREE Comfort

The XK46 network

PVC-sheathed cord of 2 × 0.75 to 2 × 1.25 mm², 250 m at most for the whole communication line. One master (address 01) and one slave (address 02) on the same units.

XK46 manual, GREE Canada
Did you know?

Six wiring and setup details from the submittals.

LogisVert · Hydro-Québec

LogisVert pays for the heat pump, not the control.

No amount for a controller

The LogisVert amount is calculated on the heat pump’s heating capacity at −8 °C, AHRI number by AHRI number. A controller or an adapter has no AHRI number: it is not on Hydro-Québec’s list of Oct. 27, 2026. System amounts are on their own pages, for example GREE multi-zone.

Questions

Nest, Wi-Fi, distance: what people ask us about GREE controls.

Which controller goes with my GREE unit?
It depends on the line: XE72-44/E on All Match R32 high-static ducts and cassettes, XK76 on the Free Match R32 and the 8-way cassette, XE-71 or XK-19 on the R410A Free Match units. Give us the indoor unit’s model number: we will tell you which one GREE names.
Can I keep my Nest thermostat?
On a ductless GREE unit, through the ME34-44/G adapter: GREE gives Nest as an example of a 24 VAC thermostat. On a UNIX R32 central system, the GREE documents differ: GREE Canada’s brochure says it works with most 24 V wired thermostats, manual X40273A requires the WK-010WC1. We check yours at the visit.
Which one has a weekly schedule?
The XK76: 7 days, 8 segments a day, for wall units and the Free Match R32. On a GMV, the XE70-33/H: 7 days, up to 4 schedules.
Which one works from a phone?
The XE72-44/E: its manual says the GREE+ app can run it. GREE Comfort also presents an “XE72” as the Wi-Fi controller for A and B series cassettes, floor/ceiling units and slim ducts; no document says it is the same model.
How far from the unit can the controller go?
It depends on the document: 26 ft of harness for GREE Comfort’s controllers, up to 20 m (8 m as standard) per the Canadian XE72-44/E and XE71-44/G manuals, and 250 m of line in total for a GMV’s XK46.
Can an XE71 replace my XK19?
Yes per GREE Comfort’s compatibility guide, provided the harness is replaced too. We first check that your unit is among those the XE71 submittal names.
AirGreen

The right controller for your system? We read the model number, then wire it.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
One document per answerEvery pairing in the tool cites the brochure, drawing or submittal it comes from.
Sources

Pairings and limits as published in each document; where two documents differ, both values are given. Documents read Oct. 26, 2026; page updated Oct. 28, 2026.