Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
GREE Free Match M Series heat pumps, 3 rooms. The 24,000 stops at three units and 15 m of height; the 30,000 goes to 25 m and accepts a fourth room. Three answers about your home are enough to choose.
4 M Series three-room systems, from 24,000 to 42,000 BTU/h, on R-410A. A bungalow’s two bedrooms and living room, or three rooms over two or three floors. The real choice is between the 24,000 and the 30,000: the first is lighter and quieter, the second accepts more height and more line set.
- 4three-room systems on this page
- 24,000–42,000BTU/h, rated
- 4/4ENERGY STAR cold climate, by non-ducted AHRI number
- R-410Asold while stocks last
24,000 or 30,000? Three questions about your home settle it.
The 24,000 has three limits the 30,000 does not: 15 m of height, 20 m of line set for one room and no fourth unit. Answer for your home; the answer also says what the next step up costs and earns.
Three answers about your home
Measured or estimated, they are enough to settle the 24,000 against the 30,000 on the limits GREE Canada publishes. Heat is calculated at the visit.
Limits, weight, sound and circuit: GREE Canada, document 062024. Heat: NEEP, read Oct. 26, 2026. LogisVert: the amounts, indicative, come from Hydro-Québec’s list of Oct. 27, 2026. “Longest line set”: GREE Canada’s maximum pipe length, read as the limit for each line set.
What the M Series gives three rooms, from the 24,000 to the 42,000.
Figures in bold are the 24,000’s own limits. Above it, the 36,000 and 42,000 stand apart mostly on heat and on the LogisVert amount.
| M Series | 24,000 | 30,000 | 36,000 | 42,000 |
|---|---|---|---|---|
| Indoor units allowed | 2 to 3 | 2 to 4 | 2 to 4 | 2 to 5 |
| Rated at −8.3 °C (NEEP) | 23,600 | 27,200 | 30,800 | 35,600 |
| Maximum at −15 °C (NEEP) | 21,600 | 22,800 | 32,400 | 32,400 |
| Maximum at −30 °C (NEEP) | 17,220 | 20,020 | 24,020 | 24,500 |
| LogisVert, list of Oct. 27, 2026 | $2,832 | $3,264 | $3,696 | $4,272 |
| Maximum length · total | 20 m · 60 m | 25 m · 80 m | 25 m · 80 m | 25 m · 100 m |
| Height, between units and to the outdoor unit | 15 m | 25 m | 25 m | 25 m |
| Factory pre-charged (Dettson) | 30 m | 40 m | 40 m | 40 m |
| Height · net weight | 660 mm · 52.0 kg | 826 mm · 69.0 kg | 826 mm · 78.0 kg | 826 mm · 79.0 kg |
| Sound, outdoor unit | 58 dB(A) | 63 dB(A) | 63 dB(A) | 63 dB(A) |
| MCA · maximum protection | 19 A · 25 A | 23 A · 35 A | 29 A · 45 A | 29 A · 45 A |
| Heat for each room, three units | not published | not published | not published | not published |
Sources: GREE Canada 062024 for limits, cabinet, sound and circuit; Dettson X61019_C for the pre-charge. Heat: NEEP as of Oct. 26, 2026; amounts: LogisVert list of Oct. 27, 2026, indicative. Non-ducted AHRI numbers: 208786090, 208786091, 208786087 and 208786088. “Maximum length”: that of each line set.
Three-unit combination table: not published
GREE Canada makes no three-unit combination public for the M Series: its tables are kept for dealers. This page therefore gives no per-room share, and borrows none from another line. It is checked in the quote.
Other room counts on the M Series, or triple-zone across every line, R-32 included:
Three rooms on an M Series: heights and lengths are measured before the size.
The M Series comes from GREE; the size depends on your house. AirGreen takes the height between floors and the length of each line set, calculates the heat, then picks the size.
What GREE brings
- Three rooms on four sizesGREE Canada allows three units on the 24,000, 30,000, 36,000 and 42,000.
- Two published heightsBetween indoor units, and between the outdoor unit and the indoor units: GREE Canada gives both for every size.
- Cold climate at every sizeAt ENERGY STAR, the non-ducted 24,000, 30,000, 36,000 and 42,000 carry both the cold-climate and the Most Efficient marks.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateAt the visit, tape and level first: heights, lengths, then the size.
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: an M Series that respects your heights and lengths, and three rooms warm in winter.
Three rooms on an M Series: the 4 systems for sale.
On each sheet: the AHRI number for the non-ducted configuration. The 24,000 or 30,000 choice is at the top of the page; the four sizes side by side, right after.
The 24,000 or larger: three tools to prepare the visit.
GREE Canada’s limits, Dettson’s pre-charge and NEEP’s capacities, set to three M Series rooms.
Your three lengths, against each size’s limits.
Three lengths, one size: each line set is checked against GREE Canada’s limit, their sum against the total allowed, then against Dettson’s pre-charge. The height allowed is recalled below.
Go from the 24,000 to the 30,000, then to the 36,000: watch the −15 °C bar.
The bars show the NEEP capacities of the non-ducted AHRI number, for the whole system. The three units share that heat, in proportions GREE Canada does not publish for the M Series.
For Montréal’s design temperature and normals, the GREE multi-zone page gives the sources.
The noise outside: 58 dB(A) for the 24,000, 63 for the others.
GREE Canada does not give the measuring distance. On Québec.ca’s scale, 58 dB(A) sits between moderate rain and a normal conversation; 63 dB(A), between a normal conversation and a busy street.
Three rooms on the M Series: the circuit, the charge, the heights.
The circuit
Circuit per GREE Canada: 19 A MCA and 25 A maximum protection for the 24,000; 23 A and 35 A for the 30,000; 29 A and 45 A for the 36,000 and 42,000. The outdoor unit itself feeds the three indoor units (208-230 V, single phase).
GREE Canada 062024The refrigerant
The 24,000 holds 2.4 kg of R-410A, pre-charged for 30 m of line set; 3.0, 3.7 and 3.8 kg on the three larger sizes, pre-charged for 40 m. Beyond that, how much R-410A to add: no public M Series document says.
GREE Canada 062024 · Dettson X61019The line sizes
Same diameters on all four sizes per GREE Canada: 9.52 mm (3/8 in) suction, 6.35 mm (1/4 in) liquid. From one size to the next, what changes is the length and height allowed, not the lines.
GREE Canada 06202424,000 or 30,000: six cards to flip.
Three rooms: from $2,832 to $4,272 on the M Series.
Indicative amounts taken from the list of Oct. 27, 2026; the final amount is the one Hydro-Québec grants when you apply. For comparison, the Free Match M R32 gets $2,832, $3,360, $4,320 and $5,340 at the same sizes. The federal Greener Homes program ($2,500 / $5,000) is closed: it took its last applications on Sept. 30, 2025.
Three rooms, heights and line sets: what people ask.
Which M Series sizes take three rooms?
24,000 or 30,000 for three rooms?
Three rooms on three floors: does height matter?
How much line set per room?
Does the R-32 version get more LogisVert for three rooms?
Does the 24,000 still heat at −30 °C?
Your heights, your lengths, then the size: we start by measuring.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- GREE Canada, Free Match M Series brochure (R-410A), document Rev. A 062024, English and French versions
- Dettson, Free Match M Series sheet, document X61019_C (Wolseley network)
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- Natural Resources Canada, Canada Greener Homes Grant (Québec): program closed, applications until Sept. 30, 2025, read Oct. 26, 2026
- Québec.ca, “Mesure du bruit” (in French), examples of noise sources (updated June 16, 2022), read Oct. 14, 2026
- National Building Code of Canada 2020, Appendix C, Table C-2 (Montréal, City Hall)
- AirGreen GREE page: Elite status and installations, facts checked Oct. 5, 2026; GREE installation count of Oct. 14, 2026
Capacities and amounts: indicative, to be confirmed in the quote. Tool calculations: AirGreen, from the published values above. Page updated Oct. 27, 2026; NEEP records, ENERGY STAR and the LogisVert list checked again that day.