Complete systems first, with what NEEP publishes for the ducted unit and its outdoor unit; then the R-410A heads, whose figures depend on the system they join.
R-32Current generation
All Match Slim Duct R32
LIV30HP230V1R32AO, LIV36HP230V1R32AO, VIR09HP230V1R32AO, VIR12HP230V1R32AO, VIR18HP230V1R32AO, VIR24HP230V1R32AO
- −30 °Clowest point catalogued by NEEP
- 23,800max. BTU/h at −15 °C (NEEP)
- 27,600max. BTU/h at −8 °C (NEEP)
9,000 to 36,000 BTU/h · 6 listings
ENERGY STAR cold climate for 3 of 6 systems
Documented by GREE Comfort; the pressure is set from the included XE72-44/E wired controller. On the LogisVert list: the 12,000 at $1,200 and the 36,000 at $3,264, the highest amount on this page.
Documentation: GREE Comfort, Slim Duct R32 brochure and DUC09 and DUC36 submittals
R-32Current generation
Ducted · Extreme R32
GWH09AVDXE-D6DNA1B/O, GWH12AVDXE-D6DNA1B/O, GWH18AVEXF-D6DNA1B/O, GWH24AVEXH-D6DNA1B/O
- −30 °Clowest point catalogued by NEEP
- 21,000max. BTU/h at −15 °C (NEEP)
- 21,000max. BTU/h at −8 °C (NEEP)
9,000 to 24,000 BTU/h · 4 listings
ENERGY STAR cold climate for every system
LogisVert up to $2,400 indicative
The 24,000 keeps 21,000 BTU/h at −15 °C on NEEP, as much as at −8.3 °C. LogisVert: $1,236 to $2,400.
Documentation: GREE Canada, high-static ducted brochure (062025)
R-32Current generation
Ducted · Crossover R32
GWH09AGCXD-D6DNA4D/O, GWH12AGCXD-D6DNA4D/O, GWH18AGDXF-D6DNA4B/O, GWH24AGEXF-D6DNA4J/O
- −30 °Clowest point catalogued by NEEP
- 19,600max. BTU/h at −15 °C (NEEP)
- 20,000max. BTU/h at −8 °C (NEEP)
9,000 to 24,000 BTU/h · 4 listings
ENERGY STAR cold climate for every system
LogisVert up to $2,376 indicative
The 24,000 gives 19,600 BTU/h at −15 °C on NEEP and $2,376 on the LogisVert list, $24 less than the Extreme.
Documentation: GREE Canada, high-static ducted brochure (062025)
R-32Current generation
Ducted · Clivia R32
GWH09AUCXD-D6DNA1C/O, GWH12AUCXD-D6DNA2D, GWH18AUDXF-D6DNA1A/O, GWH24AUDXF-D6DNA2J
- −30 °Clowest point catalogued by NEEP
- 15,000max. BTU/h at −15 °C (NEEP)
- 18,500max. BTU/h at −8 °C (NEEP)
9,000 to 24,000 BTU/h · 4 listings
ENERGY STAR cold climate for 2 of 4 systems
LogisVert up to $1,764 indicative
On GREE Canada’s Clivia outdoor units. The 9,000 and 18,000 are certified; the 12,000 and 24,000 have no published AHRI number: the pairing is confirmed in the quote.
Documentation: GREE Canada, high-static ducted brochure (062025)
R-32Current generation
Ducted · Airy R32
GWH09AVDXE-D6DNA1B/O, GWH12AVDXE-D6DNA1B/O, GWH18AVEXF-D6DNA1B/O, GWH24AVEXH-D6DNA1B/O
- −30 °Clowest point catalogued by NEEP
- 21,000max. BTU/h at −15 °C (NEEP)
- 21,000max. BTU/h at −8 °C (NEEP)
9,000 to 24,000 BTU/h · 4 listings
ENERGY STAR cold climate for every system
LogisVert up to $2,400 indicative
Under the Airy name, the same ducted unit on the Extreme outdoor units: same AHRI numbers, so the same figures and amounts as the Extreme card.
Documentation: GREE Canada, high-static ducted brochure (062025)
R-32Current generation
Ducted · X-Match R32
GWH30ATEXH-D6DNA1G/O, GWH36ATEXH-D6DNA1G/O
- −25 °Clowest point catalogued by NEEP
- 23,800max. BTU/h at −15 °C (NEEP)
- 27,600max. BTU/h at −8 °C (NEEP)
30,000 to 36,000 BTU/h · 2 listings
ENERGY STAR, without the cold-climate designation
LogisVert up to $1,200 indicative
GREE Canada’s 30,000 and 36,000, thinner than the others: 260 mm against 300. ENERGY STAR without cold climate: $1,200 and $1,170.
Documentation: GREE Canada, high-static ducted brochure (062025)
R-410AIndoor unit for a multi-zone system
Free Match R-410A · high static
9,000 to 24,000 BTU/h · 5 listings
60 Pa rated at 9,000 and 12,000, 90 Pa at 18,000 and 24,000, for 300 mm of thickness: the R-410A head to pick when the duct runs are long.
Documentation: GREE Canada, Free Match M brochure (Rev. A 062024)
R-410AIndoor unit for a multi-zone system
Free Match R-410A · low static
9,000 to 24,000 BTU/h · 5 listings
The thinnest on this page, 200 mm, but built for low pressure: 10 Pa rated up to 18,000, 15 Pa at 21,000 and 24,000.
Documentation: GREE Canada, Free Match M brochure (Rev. A 062024)
R-410AIndoor unit for a multi-zone system
DUCT..BD high static
9,000 to 24,000 BTU/h · 4 listings
A multi-zone head that GREE Comfort also lists as compatible with the single-zone Vireo GEN3 outdoor unit. 0.6 in. w.c. at 9,000 and 12,000, 0.8 in. at 18,000 and 24,000, 1 1/8 in drain, and “Outside air capability” per GREE Comfort.
Documentation: GREE Comfort, Slim Duct and Vireo GEN3 brochures
The Airy and Extreme listings share their outdoor units and AHRI numbers. For a ducted unit in just one room of a multi-zone, see the GREE multi-zone page.