GREE Crossover R32 Ducted | 9000 BTU | Montréal, Laval, South Shore

Only 1 left
Subvention Provinciale (LogisVert) : $ (Mise à Jour : 26 Novembre 2025)
Numéro de Modèle (Intérieur) : GFH(09)DA-D6DNA1A/I
Numéro de Modèle (Extérieur) : GWH09AGCXD-D6DNA4D/O
AHRI : 216618210
ENERGY STAR® : Oui
ENERGY STAR® (Cold Climate) : Oui / Yes
# ID ENERGY STAR : 3893635
Capacité de Chauffage : -30°C
Capacité de Refroidissement : 9 000 BTU
Gaz (Fréon) : R-32
WiFi : En Option

SEER2 (Efficacité de climatisation en saison)

1 22.0 30

HSPF2 (Efficacité de chauffage en saison)

1 9.2 15

EER2 (Efficacité instantanée en climatisation)

1 14.2 20
Puissance Nominale : 9 000 BTU
Puissance à -8 °C : 8800 BTU
Puissance à -15 °C : 9500 BTU
Puissance à -30 °C (MAX) : 6900 BTU

COP à -8 °C (Rendement énergétique du chauffage)

1 2.8 4

COP à -15 °C (Rendement énergétique du chauffage)

1 2.16 4

COP à -30 °C (MAX)

1.3 4
Dimensions Intérieure (L x P x H) : 32.68 x 29.68 x 11.81 po
Déshumidification : 1.69 (pt/h)
Niveau de Pression Sonore (Intérieur) : 25 / 36 dB(A)

CFM (Débit d'air)

1 324 700
Dimensions Extérieures (L x P x H) : 31.58 x 13.78 x 21.84 po
Tuyauterie : 1/4 - 3/8 po
Niveau de Pression Sonore (Extérieur) : 52.0 dB(A)
Tension : 220V
MCA (Ampacité minimale du circuit) : 10A
MOP (Protection maximale surintensité) : 15A
Garantie (Compresseur - Pièces - Main-d’œuvre) : 10-10-0 ans
Garantie Supplémentaire : Possible

A 9,000 BTU Ducted Unit, When the Room Matters More Than the Equipment

At AirGreen, we have been installing ducted systems long enough to know that the smallest capacity in a lineup is rarely a default choice. The 9,000 BTU GREE Crossover R32 is the unit we offer when a customer wants to heat and cool a specific area without any visible equipment: a primary bedroom added above the garage, a finished basement office, or a condo whose association prohibits wall-mounted units in visible common areas.

The indoor unit fits into a suspended ceiling, a corridor soffit, or a service space, and the air exits through grilles. The result is a room with no visible trace of its HVAC system.

What a concealed unit changes

A wall-mounted heat pump makes its presence known: it requires wall space, clearance, and a directed airflow. A ducted system moves that constraint to the ceiling and replaces it with a design question. Where will the ducts run, how long will they be, how many grilles are needed, and what will the pressure drop be? This requires more work during planning and far fewer compromises once the installation is complete.

The Crossover R32 is a high-static-pressure unit. The distinction is practical: a low-pressure ducted unit pushes air a few feet and struggles as soon as an elbow or filter is added. This one handles a real duct network, with branches leading to two or three grilles, without airflow collapsing in the farthest room.

The certified figures

We do not repeat brochure values. The figures below come from AHRI Certificate 216618210 and ENERGY STAR listing 3893635 - the same data reviewed by Hydro-Québec and rebate programs.

Seasonal efficiency

  • 22.0 SEER2 in cooling
  • 14.2 EER2 at full load
  • 9.2 HSPF2 in heating

Heating when it is truly cold

  • At -8 °C: 8,800 BTU/h, COP of 2.8
  • At -15 °C: 9,500 BTU/h, COP of 2.16
  • Down to -30 °C: 6,900 BTU/h at maximum capacity

The figure to remember is not the first one, but the second. At -15 °C, the unit still delivers 9,500 BTU/h, which is more than it delivers at -8 °C. A well-designed variable-speed compressor adjusts its frequency to demand: when the heating load increases, it increases with it. That is exactly the behaviour we want for a Quebec winter, and it is why this model has earned ENERGY STAR's cold-climate designation.

When 9,000 BTU is the right choice - and when it is not

We regularly refuse to sell this capacity. An oversized unit is one that starts, reaches the setpoint within a few minutes, stops, and then starts again. This short cycling costs more in electricity, wears out the compressor, and, above all, does not dehumidify.

The 9,000 BTU model suits an approximately 300 to 400 square foot, well-insulated area with moderate sun exposure and standard-height ceilings. A large open-concept main floor, a room with a full south-facing curtain wall, or an uninsulated basement requires the next capacity up. We perform a load calculation before recommending anything, and sometimes conclude that the right answer is a 12,000 or 18,000 BTU unit.

Humidity, the variable people forget

This model removes 1.69 pints of water per hour from the surrounding air. In July in Montreal, this figure often determines actual comfort more than the displayed temperature. A room at 23 °C with 65% humidity is uncomfortable; the same room at 24 °C with 48% humidity is not. A properly sized unit runs for long periods at low speed and continuously dries the air, which an oversized unit never does.

Silence as a criterion

The indoor unit ranges from 24 to 38 dB(A). The low end is below the sound level of a library, and it is the speed at which the unit operates most of the time. In a bedroom, this translates into a gentle airflow that you stop noticing after two days. The outdoor unit operates at 52 dB(A), which matters when it is near a neighbour's window - a common situation on the Plateau or in Verdun.

What the installation really requires

Space

The indoor unit measures 32.67 x 29.69 x 11.81 inches. Its 11.81-inch height is the determining constraint: sufficient ceiling clearance is required, along with room for the duct connections and filter access. We check this dimension on site before confirming feasibility, never from plans alone.

The outdoor unit measures 31.58 x 13.78 x 21.84 inches and connects with 1/4 - 3/8 inch piping, the smallest in the lineup. On a narrow rear balcony or in a city backyard, this compactness can make the difference between a feasible project and an abandoned one.

Electrical

220 V power supply, minimum circuit ampacity of 10 A, maximum protection of 15 A. These are modest requirements, so it is often possible to add the circuit without modifying the existing panel. We verify the panel's capacity during the quotation stage, before the electrician comes out.

R-32 refrigerant

R-32 has a global warming potential approximately three times lower than the R-410A it replaces, and it transfers heat more efficiently, which partly explains the efficiency ratings above. Our technicians are trained and equipped to work with A2L refrigerants, using the detectors and procedures required by the standard.

Our fieldwork

We cover Montreal, Laval, Longueuil, the North Shore, and the South Shore. A ducted system is not a unit you simply hang: duct routing, condensate placement, future filter access, and the network's static pressure are determined before the first cut. This planning is what distinguishes an installation that lasts ten years from one that generates service calls starting in its first summer.

Eligibility for financial assistance programs depends on the exact model and installation date. We verify it for your file before submitting the quotation, rather than advertising an amount that may not apply.

Request Your Quote

Send us the dimensions of the area to be treated and a photo of the available ceiling space. We will come back with a load calculation, a realistic duct layout, and an installed price - without making assumptions about what we have not seen.