Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
GREE UNIX R32 heat pump on a furnace, GCAC coil. GREE Canada’s brochure says one thing, the certificate another: which figures do you keep for your coil?
4 UNIX R32 systems on a GCAC coil, from 24,000 to 60,000 BTU/h. GREE Canada publishes their technical page in its brochure 062025: capacities, efficiencies, water removal, drain. NEEP and ENERGY STAR certify the same AHRI numbers. Tonnage by tonnage, we set the two side by side.
- 4UNIX R32 coil systems on this page
- 60 to 62 dB(A)at the outdoor unit, 2 to 5 tons
- 3.20 / 3.10COP at 8 °C, 2 to 4 tons then 5 tons
- 2.9 / 4.6 kgof R-32 from the factory, GUD36W2 then GUD60W2
Pick a tonnage: brochure 062025 on one side, NEEP and ENERGY STAR on the other.
Both describe the same system. At 2 and 3 tons they agree; at 4 and 5 tons the brochure is more cautious on efficiency and, at 5 tons, gives 1,000 BTU/h less in heating. For LogisVert, the certificate is what counts.
Same AHRI number, two documents
Pick the tonnage. On the left, page 3 of GREE Canada’s brochure 062025; on the right, the NEEP and ENERGY STAR record for the same AHRI number. In bold, what the certificate says differently.
What the coil takes out of the air, and where it goes.
In cooling, the coil dries the house air. GREE Canada is the only source we read that publishes how much, system by system; the water leaves through a ø 19 mm (3/4 in) drain.
Moisture removal printed in L/h and pints per hour, page 3 of brochure 062025.
A brochure, a certificate, and a team that keeps the right figure.
GREE designs the UNIX R32 and its GCAC coil; GREE Canada publishes brochure 062025. AirGreen reads it next to the certificates, installs the system on your furnace and leaves the gas or oil side to a licensed partner.
What GREE brings
- Two condensers, four coilsGUD36W2/NhE-D(U) for the 24 and 36 coils, GUD60W2/NhE-D(U) for the 48 and 60.
- Two ways to installA complete GREE kit, or a retrofit with a furnace combined with a cased coil, “to reduce labor and equipment costs”.
- DownflowThe UNIX R32 series is listed as compatible with downflow applications.
What AirGreen brings
- GREE Elite dealerGREE training completed, priority access to original parts.
- Free estimateWe compare your furnace with brochure 062025 before choosing the tonnage.
- RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The result: a GCAC coil whose every figure has its source, a LogisVert amount taken from the certificate, and the gas side left to the right licence holder.
All 4 UNIX R32 coil systems, right below.
Each listing names the GUD..W2/NhE and the GCAC..NhA coil. The UNIX R32 on an air handler is on the GREE Canada UNIX R32 page; the same coil documented by Dettson, on the Dettson GCAC page.
GREE Canada’s GCAC coil: page 3 of brochure 062025.
| GREE Canada 062025 | 24,000 | 36,000 | 48,000 | 60,000 |
|---|---|---|---|---|
| Outdoor unit | GUD36W2/NhE-D(U) | GUD36W2/NhE-D(U) | GUD60W2/NhE-D(U) | GUD60W2/NhE-D(U) |
| Coil, W x H x D | 445 x 584 x 540 mm | 445 x 584 x 540 mm | 622 x 724 x 540 mm | 622 x 724 x 540 mm |
| Net / gross weight | 34.0 / 38.0 kg | 34.0 / 38.0 kg | 50.0 / 56.0 kg | 50.0 / 56.0 kg |
| Outdoor sound | 60 dB(A) | 61 dB(A) | 62 dB(A) | 62 dB(A) |
| Outdoor MCA / MOP | 27.7 / 30 A | 27.7 / 30 A | 39.9 / 45 A | 39.9 / 45 A |
| R-32 charge | 2.9 kg (102.3 oz) | 2.9 kg (102.3 oz) | 4.6 kg (162.3 oz) | 4.6 kg (162.3 oz) |
| Condensate drain | ø 19 mm (3/4 in) | ø 19 mm (3/4 in) | ø 19 mm (3/4 in) | ø 19 mm (3/4 in) |
GREE Canada, “UNIX R32 central system” brochure, document 062025, page 3. Line set: 7.5 m (24.6 ft) standard, 30 m (98.4 ft) maximum, 15 m (49.2 ft) height difference. Widths in inches: 17-1/2 and 24-1/2; heights: 23 and 28-1/2; depth: 21-1/4. Sound measuring distance: not published by GREE Canada.
Four things to know about brochure 062025. Flip the cards.
LogisVert and the UNIX R32 on a coil: the list follows ENERGY STAR.
Hydro-Québec list dated Oct. 27, 2026: $120 per 1,000 BTU/h at −8.3 °C, ENERGY STAR’s value, for an ENERGY STAR cold-climate heat pump. Indicative amounts, confirmed when you apply; what the guide says about an add-on that keeps the furnace is on the ADD-ON page.
What people ask us about the UNIX R32 on a coil.
What does GREE Canada publish for the 5-ton system?
The brochure and NEEP differ: which one counts?
How is the coil drained?
How does it differ from Dettson’s GCAC coil?
Can I keep my furnace with the UNIX R32?
What warranty does GREE Canada publish?
The UNIX R32 on your furnace? We read the brochure and the certificate with you.
Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.
- Product sheets on airgreen.ca (metafields), read Oct. 14, 2026
- NEEP cold-climate heat pump list, records by AHRI number, read Oct. 14 and 15, 2026 and checked again Oct. 26 and 27, 2026
- ENERGY STAR, “Certified Air-Source Heat Pumps” (data.energystar.gov, dataset w7cv-9xjt, updated Oct. 25, 2026, read Oct. 26 and 27, 2026)
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file proprietaire-habitation-existante-20261027 downloaded Oct. 26, 2026, checked again Oct. 27, 2026 against the next file, proprietaire-habitation-existante-20261028: same amounts for every AHRI number on our product sheets
- Hydro-Québec, LogisVert program, residential participant guide, version 1.10, Sept. 15, 2026, still online Oct. 26, 2026
- GREE Canada, “UNIX R32 central system” brochure, document No. 062025, page 3 (cased coil)
- GREE Canada, UNIX R32 product page, read Oct. 26, 2026
- GREE Canada, “UNIX R32 central system” brochure, document No. 062025, French version
- Dettson, X60062F submittal, GREE FLEXX R32, French version, read Oct. 26, 2026
Capacities and amounts: indicative, to be confirmed in the quote. Tool answers: AirGreen, from the published values above. Page updated Oct. 26, 2026; NEEP and ENERGY STAR records checked again that day, LogisVert list dated Oct. 27, 2026.