AirGreenGREE
GREE EliteThe GREE space at AirGreen · GUD..AH2/G air handler · UNIX R32GREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
R-32 · GREE Canada
GREE electric furnace · UNIX R32 · Updated Oct. 27, 2026

GREE UNIX R32 electric furnace. Will your ducts let this air handler move enough air? And which kit can it take? The GREE manual answers, speed by speed.

4 UNIX R32 systems, 2 to 5 tons, with the GUD..AH2/G-D(U) air handler. When an electric furnace is replaced, its ducts often stay. Before keeping them, we look at what the GREE blower moves at the pressure it will meet there.

760 CFMWhat the GUD24AH2/G moves on speed 3 at 0.5 in. w.c. The GREE manual underlines that cell: no heat kit at this setting. On speed 4, 1,370 CFM.
20 kWThe largest kit in the GREE manual, the LYQ-08-E, for 4- and 5-ton air handlers only. The 15 kW needs 3 tons or more; the 5 and 10 kW fit every size.
373 m³/hMinimum airflow the manual sets for A2L safety on the 2- and 3-ton air handlers; 540 m³/h for the 4- and 5-ton.
  • 4UNIX R32 systems
  • 2–5tons
  • 5blower speeds in the table
  • 0.5 in. w.c.rated pressure, per GREE Canada
AirGreen × GREEGREE Elite dealerGUD..AH2/G air handler · UNIX R32Airflow, speed by speedLYQ-08 heat kits, 5 to 20 kWMontréal, Laval, Longueuil, South Shore, North Shore
Your ducts, its blower

At your ducts’ pressure, how much airflow is left?

One question: how much pressure does your ductwork put against the blower? The tool uses the GREE manual’s table for all four air handlers, speed by speed, with the cells where the heat kit is not allowed.

Your ducts’ pressure

GREE Canada rates these air handlers at 0.5 in. w.c. (125 Pa). Pick the pressure measured on your ducts: the table gives each speed’s airflow for the four tonnages, and flags the cells where the manual rules out the electric kit.

Static pressure and airflow table from the GREE manual for the GUD..AH2/G-D(U) air handlers, document X40273A published by Dettson, pp. 16-17: “—” and underlined values mark where electric heating is not allowed. Speed is set with eight DIP switches, before power-up.

Elsewhere in this family: FXU air handler (FLEXX ULTRA R32) · GUD..AH2/E air handler (FLEXX R32) · All GREE electric furnaces.

The air handler, size by size

Four air handlers: size, kit, filter, room.

What changes from one tonnage to the next, as GREE Canada and the GREE manual print it. GREE Canada, NEEP, ENERGY STAR and Hydro-Québec list these systems with the GUD..AH2/G-D(U) air handler.

GUD24AH2/GGUD36AH2/GGUD48AH2/GGUD60AH2/G
Outdoor unitGUD36W2/NhE-D(U)GUD36W2/NhE-D(U)GUD60W2/NhE-D(U)GUD60W2/NhE-D(U)
System AHRI number217120759217120760217120761217120762
Dimensions, W × H × D460 × 1,105 × 540 mm540 × 1,224 × 540 mm630 × 1,320 × 540 mm630 × 1,320 × 540 mm
Net weight61.5 kg74.0 kg90.5 kg90.5 kg
Rated airflow760 CFM1,000 CFM1,200 CFM1,500 CFM
LYQ-08 kits in the manual5, 10 kW5, 10, 15 kW5, 10, 15, 20 kW5, 10, 15, 20 kW
Filter420 × 516 × 15 mm490 × 516 × 15 mm525 × 516 × 15 mm525 × 516 × 15 mm
A2L minimum airflow373 m³/h373 m³/h540 m³/h540 m³/h
Blower only, minimum circuit4.7 A5.3 A7.1 A7.7 A
R-32 charge and minimum room 2.2 m ceiling2.9 kg · 8.6 m²2.9 kg · 8.6 m²4.6 kg · 13.7 m²4.6 kg · 13.7 m²
Indoor sound pressure50 dB(A)51 dB(A)52 dB(A)53 dB(A)

GREE Canada, UNIX R32 brochure: pairing, AHRI, dimensions, weight, airflow, circuit (15 A protection), factory charge, sound. GREE manual X40273A: kits by tonnage, filters, A2L minimum airflow, room area by charge. The area required is worked out again from the charge actually installed.

AirGreen × GREE

A UNIX R32 air handler set to your ducts.

GREE designs the air handler and publishes its airflow at each pressure. AirGreen measures your ducts, sets the speed and chooses the kit.

GREE

What GREE brings

  • Five speeds publishedThe manual gives each speed’s airflow from 0 to 1.0 in. w.c., and the cells where the kit is not allowed.
  • Four LYQ-08 kits5 and 10 kW on every air handler, 15 kW from 3 tons, 20 kW on 4 and 5 tons.
  • A detector on every air handlerGREE Canada lists a leak detector on all of its air handlers; the manual gives it a fifteen-year service life.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe measure your ducts’ static pressure before keeping the existing ductwork.
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: a UNIX R32 air handler that moves its intended airflow through your ducts, with the kit its tonnage allows.

The GREE shop

All 4 UNIX R32 air-handler systems, right below.

Each listing gives the system’s AHRI number. The heat kit is ordered separately, by the air handler’s tonnage.

GREE
Technician’s corner

The GUD..AH2/G at installation.

The kit’s circuit

Without a kit: 4.7 to 7.7 A, 15 A protection. For the kit, GREE Canada publishes no MCA or MOP: its note refers to the certified technician. The electrician sets them from the kit’s nameplate.

GREE Canada, UNIX R32 brochure, note *

The terminals

W2/AUX drives the kit, L carries the leak protection signal, H1/H2 are for RS485. In the first wiring configuration, with a kit, W2/AUX and R are jumpered together.

GREE manual X40273A, pp. 29-30

The filter

Every installation must have a return-air filter: 420 × 516 × 15 mm for the 2-ton, 490 × 516 × 15 mm for the 3-ton, 525 × 516 × 15 mm for the 4- and 5-ton.

Manual X40273A, pp. 13 and 19
Did you know?

The UNIX R32 air handler, in six cards.

LogisVert · Hydro-Québec

LogisVert: four AHRI numbers, one /G air handler.

Hydro-Québec’s list of Oct. 27, 2026 holds AHRI numbers 217120759 to 217120762, each with a GUD..AH2/G-D(U) air handler. Hydro-Québec bases the amount on the UNIX R32 heat pump’s capacity, not on the heat kit. The indicative amounts, by tonnage, are on the UNIX R32 central heat pump page; Hydro-Québec confirms them once you apply.

Questions

UNIX R32: what people ask before replacing a furnace.

Is this air handler a furnace?
It is the indoor unit of the UNIX R32 heat pump. Electric heat is added as an option: GREE Canada calls the auxiliary heater optional.
Which heat kit can it take?
The GREE manual lists the LYQ-08-A (5 kW) and LYQ-08-C (10 kW) from 2 to 5 tons, the LYQ-08-D (15 kW) from 3 tons and the LYQ-08-E (20 kW) for 4 and 5 tons, all at 240 V. Your home’s heat-loss calculation says which one to take.
What breaker for the kit?
GREE Canada publishes no table: its brochure refers to the certified technician for the kit’s MCA and MOP. The electrician sets them from the nameplate of the kit delivered; AirGreen holds RBQ subcategory 16.
Will my existing ducts do?
GREE Canada rates the air handler at 0.5 in. w.c. (125 Pa). We measure your ducts’ static pressure at the visit; the tool at the top of the page then shows each speed’s airflow at that pressure, and where the kit is not allowed.
Can it go in a closet?
The 2-ton measures 460 × 1,105 × 540 mm. The room counts too: with 2.9 kg of R-32, the GREE table asks for at least 8.6 m² at a 2.2 m ceiling; with 4.6 kg, 13.7 m².
Can I keep my 24 V thermostat?
GREE Canada lists the UNIX R32 as compatible with 24 VAC thermostats and with RS485 communication. The GREE air-handler manual, however, gives the WK-010WC1 as the required thermostat: the two documents differ, so we check your model at the visit. See also the GREE thermostats page.
AirGreen

Ducts to keep, a furnace to replace? We measure, then choose the air handler and its kit.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
The manual’s tableAirflows taken from GREE manual X40273A, speed by speed, unrounded.