Packaged Heat Pump System Tosot Rooftop R32 2 Ton | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: TK-H02TC/NhA-D(U)

TOSOT 2 ton packaged heat pump for a small building

At AirGreen, we install Rooftop R32 packaged heat pumps from 2 to 5 ton. This page covers the 2 ton TOSOT TK-H02TC/NhA-D(U) model, that is 24,000 BTU/h nominal, and what its spec sheet puts forward.

A packaged heat pump brings the compressor, the coils and the fan together in a single outdoor cabinet. That cabinet connects to the building's duct system and delivers both heating and air conditioning, with no indoor unit to house in a mechanical room. The TOSOT model runs on R-32 refrigerant and is fed in 208-230 V single-phase (1 phase, 60 Hz), which suits buildings that have no three-phase service. It is all-electric: no gas is required.

The buildings a 2 ton is right for

The 2 ton size targets small buildings served by a single duct system: a neighbourhood commercial space, a professional office, a workshop, a small branch or a house where all the air travels through the same distribution. In Montreal, Laval and Longueuil, these units often find their place on the flat roofs of small commercial buildings, where owners prefer to keep the equipment outside and free up the space indoors.

Final sizing still depends on your building: insulation, windows, occupancy and the condition of the ducts. That is why we do the estimate on site, before talking about a brand or a model. If the needs exceed what a 2 ton can deliver, the same TOSOT line also comes in 3, 4 and 5 ton.

What the certificates say

In 2 ton, the TOSOT model posts the following certified values:

  • AHRI reference 218795633 and ENERGY STAR certificate 4706810, with the ENERGY STAR Cold Climate designation;
  • SEER2 of 18.0, EER2 of 11.7 and HSPF2 of 8.8 (region IV), against an EER2 of 11.2 for the 3, 4 and 5 ton models;
  • 24,000 BTU/h in cooling at 35 °C and 24,000 BTU/h in heating at 8.3 °C;
  • 15,500 BTU/h in heating at -8.3 °C (17 °F), the certified rated capacity;
  • 29,000 BTU/h at -15 °C (5 °F), measured at maximum compressor speed, with a COP of 1.90.

The value at -15 °C is higher than the one at -8.3 °C, which can be surprising on a first read. The explanation lies in how they are measured: the capacity at -8.3 °C is the certified rated value, while the one at -15 °C is measured at maximum compressor speed, under the ENERGY STAR Cold Climate criterion. The two figures therefore do not describe the same operation and cannot be compared directly. The COP of 1.90 means that, under those conditions, the unit delivers 1.90 units of heat for every unit of electricity it draws.

What the TOSOT sheet puts forward

Beyond the certified figures, TOSOT's "Submittal data" sheet describes the equipment and the control. Three points hold our attention when we advise a customer.

The TOSOT RS485 thermostat or a 24 V thermostat

The unit accepts two control modes: the TOSOT RS485 thermostat, or a standard 24 V thermostat from another manufacturer. The standard controller listed on the sheet is the XE7C-23/H. For a small business that already has a 24 V thermostat in good condition, we check whether it can be kept. For a building starting from scratch, the brand's own thermostat keeps everything with a single manufacturer, which simplifies dealings with technical support.

The Inverter rotary compressor with vapour injection (EVI)

TOSOT presents this model as a "DC Inverter Rooftop Ultra Heat Fully Electric Heat Pump", in other words a 100% electric heat pump. The unit is built around an Inverter rotary compressor with vapour injection (EVI), managed by high-efficiency DC Inverter technology. Vapour injection is a compression technique associated with cold-weather heating, while the Inverter compressor varies its speed with demand. The sheet also publishes a range of 8,600 to 25,400 BTU/h in cooling and 9,000 to 30,400 BTU/h in heating at 8.3 °C, which shows how wide that modulation is.

The 5 or 10 kW backup heat kits

Electric backup heat kits of 5 kW or 10 kW are offered as an option on the 2 ton. They add a reserve of heat for deep cold, on top of the heat pump. The 15 and 20 kW kits, for their part, are reserved for the 4 and 5 ton models. The choice between 5 and 10 kW is made with you, based on the building's needs and the capacity available at the electrical panel.

The TOSOT sheet also describes an electronic expansion valve, a centrifugal indoor blower and an aluminum air filter. To compare two quotes, rely on the AHRI and ENERGY STAR references of each unit.

The TK-H02TC on your roof: dimensions, connection and installation

A compact cabinet for a small roof

The 2 ton measures 44 × 35-7/16 × 49-1/4 in. (1,120 × 900 × 1,250 mm), in width, depth and height. It weighs 523 lb net and 545 lb gross, and holds 150 oz of R-32 refrigerant. On a flat roof, we check the load-bearing capacity of the structure and the access for handling before confirming the location with you.

Vertical or horizontal duct connection

The ducts connect vertically, through the bottom of the unit, or horizontally, through the side. The vertical connection is made on a roof curb whose dimensions TOSOT publishes; the side connection suits cases where the ducts come in through a wall. The installation clearances published in the spec sheet are respected on every job, both for access during maintenance and for air circulation around the cabinet.

Airflow, static pressure and sound level

The centrifugal indoor blower offers three airflows: 880, 700 and 600 CFM (high, medium and low speed). External static pressure is 0.5 in. as standard and can reach 0.7 in. at maximum, a useful figure when reusing an existing duct system whose resistance is unknown. The published sound pressure is 65 dB(A): we take it into account to place the unit away from neighbouring windows and terraces when the roof allows.

Electrical supply and operating range

On the electrical side, the sheet lists an MCA of 35.0 A and an MOCP of 40.0 A, at 208-230 V single-phase. Your electrician sizes the circuit from those values; the backup heat kit, if you choose one, also has to be planned for at the panel. The unit heats at outdoor temperatures from -30 °C to 24 °C and cools from -5 °C to 52 °C. This heating down to -30 °C comes on top of the ENERGY STAR Cold Climate certification, obtained for every capacity in the line.

How we help you choose

Here is the approach we follow for a small building:

  • a visit to the building, measurements and an inspection of the existing ducts;
  • an on-site assessment of the heating and cooling needs, to confirm that the 2 ton is the right fit;
  • the choice of control mode: TOSOT RS485 thermostat, an existing 24 V thermostat or a new 24 V thermostat;
  • a decision on the 5 or 10 kW backup heat kit, taking the electrical panel into account;
  • the choice between a vertical connection on a roof curb and a horizontal one through the side;
  • installation, duct connection and commissioning by our team.

If you are still comparing capacities, our packaged heat pumps page gathers the Rooftop R32 models we install, from 2 to 5 ton.

Free estimate for your small building

We install the 2 ton TOSOT packaged heat pump in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, for businesses, offices and homes connected to a single duct system. 100% free on-site estimate anywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore: call us at 514 316-2973. We will assess your building, your ducts and your electrical panel before recommending a brand and a model. AirGreen inc., RBQ licence 5645-9605-01.

Documentation

Warranty: 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.