AirGreenDIRECT AIR

The DIRECT AIR space at AirGreenSold and installed by AirGreen

DIRECT AIR × AirGreen · Air exchangers

DIRECT AIR air exchangers: eight units, from the condo to the large house.

Seven HRVs and one ERV, from 59 to 203 CFM at 0.4 in. wc of static pressure per the HVI directory. What sets them apart: airflow, recovery in deep cold, recirculation, and where they go. Here are the figures side by side, and a tool to choose.

8exchangers: 7 HRVs, 1 ERV
59–203CFM at 0.4 in. wc (HVI)
80%sensible recovery at 0 °C, HE series (HVI)
Lifetimelimited warranty on HRV cores (brochure)
Three families

With recirculation, without recirculation, or energy recovery.

An HRV recovers heat from the exhaust air; an ERV also recovers part of its moisture. Recirculation moves the house air around without exhausting it.

HRV with recirculation

PHRVR 120HE · 150HE · 200HE · PHRVR70 ES · PHRVR 104

  • HE series: up to 81% sensible heat recovery, counterflow hexagonal core, compatible with IAQ controls
  • Recirculation defrost and recirculation mode
  • ENERGY STAR and Novoclimat 2.0: HE series and PHRVR70 ES
  • PHRVR 104: bathroom turbo mode

HRV without recirculation

PHRV 96 · PHRV 140

  • Aluminum recovery core, automatic defrost
  • PHRV 96: designed for condos, 4 in. round ports
  • PHRV 140: designed for single-family homes, 6 in. oval ports

ERV (energy recovery)

PVRE 70

  • Water-permeable, frost-tolerant core: it also recovers moisture, up to 45% (latent)
  • Ceiling or wall mount, bracket included; no drain needed (spec sheet)
  • Only 9.75 in. thick (spec sheet), for the condo with no mechanical room

Direct Air HRV/ERV brochure (October 2023); PVRE 70 spec sheet.

The choice

Tick your constraints: we keep the exchangers that meet them.

Ranking is by recovery at −25 °C, the one that matters in a cold snap.

Your home

Calculating…

The figures

Eight exchangers, the same measurements, side by side.

Airflow at 0.4 in. wc of static pressure, sensible recovery at 0 °C and power at the test flow: HVI directory. Maximum recovery at −25 °C, ports and dimensions: Direct Air brochure.

ModelCFM at 0.4 in. wcSensible at 0 °CSensible at −25 °CPowerPortsL × D × H (in.)ENERGY STAR
PHRV 965963%57%42 Wtop, round, 4 in.21.50 × 10.25 × 17.12—
PHRVR70 ES7065%62%35 Wtop, oval, 5 in.21.50 × 10.28 × 17.65yes
PVRE 7070*70%*34%40 W*side, round, 4 in.21.50 × 9.75 × 19.63—
PHRVR 10410661%58%60 Wtop, oval, 5 in.21.50 × 14.50 × 17.90—
PHRVR 120HE11080%65%56 Wtop, round, 5 in.23.25 × 11.50 × 24.25yes
PHRV 14013865%58%69 Wtop, oval, 6 in.23.75 × 17.19 × 18.44—
PHRVR 150HE15080%65%60 Wtop, round, 6 in.27.88 × 13.38 × 24.88yes
PHRVR 200HE20380%67%98 Wtop, round, 6 in.27.88 × 15.38 × 24.88yes

* PVRE 70: not in the HVI directory consulted; values from its spec sheet (70 CFM at 0.4 in. wc; at 0 °C and 51 CFM: 70% and 40 W). Its latent recovery reaches 45% at 0 °C.

Warranty and controls

A DIRECT AIR HRV core has a limited lifetime warranty.

Warranty (brochure)

LifetimeHRV cores (limited warranty)
5 yearsERV cores
7 yearssealed motors (limited warranty)
5 yearsother parts
2 yearscontrols

Filters are not covered. PVRE 70: 5 years core, 7 years motors, 5 years parts (spec sheet).

Controls (brochure)

  • ECO-touch 2.0 and ECO-touch 2.0 QAI (VOC sensor): programmable touch screen, for the HE series and PHRVR70 ES only
  • DIR-DG and EDF 8: ventilation, recirculation and humidity-controlled standby modes, 3 speeds
  • EDF 3: eco mode, 20 min/h ventilation, high speed
  • RTS5: 20/40/60 timer for the bathroom, compatible with all Direct Air ventilators
Questions

What people ask us, and what the sources say.

HRV or ERV: which one?

An HRV recovers heat from the exhaust air; an ERV, like the PVRE 70, also recovers part of the moisture (up to 45% at 0 °C per its spec sheet). In a house where the air gets very dry in winter, the ERV keeps more moisture; elsewhere, an HRV is enough.

What airflow does my house need?

The ventilation airflow is calculated for the house and the applicable code. We calculate it during the visit, then choose an exchanger whose airflow at 0.4 in. wc covers that need.

What is the warranty on DIRECT AIR exchangers?

Per the brochure: HRV cores for life (limited warranty), ERV cores 5 years, sealed motors 7 years (limited warranty), other parts 5 years, controls 2 years; filters are not covered.

Which ones are ENERGY STAR and Novoclimat 2.0?

The HE series (PHRVR 120HE, 150HE and 200HE) and the PHRVR70 ES, per the brochure.

Why does the PVRE 70 have no HVI figures?

It is not in the HVI directory we consulted. So we give the values from its spec sheet: 70 CFM at 0.4 in. wc, 70% sensible recovery at 0 °C (at 51 CFM) and 34% at −25 °C.

AirGreen × DIRECT AIR

Your air exchanger, chosen for your home and installed by AirGreen.

We calculate the required airflow, look at where the ducts and drain can go, then choose the exchanger and its control. The quote shows the exact model.

Sold and installed by AirGreen · RBQ 5645-9605-01

Sources, checked on October 26, 2026

  1. HVI certified products directory, section III (heat and energy recovery ventilators), current as of October 21, 2026, reread October 26, 2026.
  2. Direct Air HRV/ERV brochure, English and French, printed October 2023 (in our files).
  3. Direct Air PVRE 70 spec sheet, French edition (item 445789, revision of December 14, 2022).
  4. airgreen.ca product pages (metafields), reread October 26, 2026.

Prices on quote. Page updated October 26, 2026.