DIRECT AIR wall heat pumps: five series, only one with a published figure at −30 °C.

The wall range has 20 models, from 6,000 to 24,000 BTU/h. In Montreal, what sets them apart is the heat they still deliver at −15, −20 or −30 °C. Here are the published figures for each, and what they mean in a Montreal winter.

20wall models online
6,000–24,000BTU/h, smallest to largest
28.1highest SEER2 (Heat Xtreme Pro R-410A 9,000)
−30 °Ccoldest heating point listed by NEEP (Heat Xtreme Pro R-454B)
12 nightsbelow −20 °C per year at Montréal-Trudeau (1991–2020 normals)
The five series

Five wall series, ranked by their coldest published point.

Order: the coldest heating point published by NEEP, then the share of their rated capacity they still deliver at −15 °C. Warranties and LogisVert amounts: on the DIRECT AIR page and on each series page.

Heat Xtreme Pro

Heat Xtreme Pro R-454B

Listed down to −30 °C (NEEP)
Sizes
6,000 · 9,000 · 12,000 · 18,000 · 24,000
At −15 °C
96 to 128% of rated capacity
SEER2
21.0 to 27.4
At the coldest point
3,200 to 11,900 BTU/h max
Refrigerant
R-454B
See the series →
DIRECT AIR

23 SEER

Listed down to −20 °C (NEEP)
Sizes
12,000 · 18,000
At −15 °C
70 to 71% of rated capacity
SEER2
21.0 to 22.5
At the coldest point
9,300 to 13,170 BTU/h max
Refrigerant
R-410A
See the series →
Heat Xtreme Pro

Heat Xtreme Pro R-410A

Listed down to −15 °C (NEEP)
Sizes
6,000 · 9,000 · 12,000 · 18,000 · 24,000
At −15 °C
100 to 125% of rated capacity
SEER2
21.5 to 28.1
At the coldest point
7,500 to 25,000 BTU/h max
Refrigerant
R-410A
See the series →
DIRECT AIR

DA25

Listed down to −15 °C (NEEP)
Sizes
9,000 · 12,000 · 18,000 · 24,000
At −15 °C
63 to 83% of rated capacity
SEER2
22.0 to 25.5
At the coldest point
8,000 to 17,500 BTU/h max
Refrigerant
R-410A
See the series →
DIRECT AIR

18 SEER

Not listed with ENERGY STAR or NEEP
Sizes
9,000 · 12,000 · 18,000 · 24,000
At −15 °C
not listed
SEER2
not listed
At the coldest point
not listed
Refrigerant
R-410A
See the series →

Sources: NEEP and ENERGY STAR, read October 14, 2026 and rechecked October 26, 2026. Share of capacity: ENERGY STAR rated heat at −15 °C ÷ the size’s rated capacity. “BTU/h max”: NEEP maximum capacity at each size’s coldest point.

Cold weather, in published figures

How much heat at −15, −20 or −30 °C? Pick a size.

Maximum heating capacity listed by NEEP at each temperature, with the COP at that output. An empty cell means no figure is published at that temperature, not that the unit stops.

Maximum capacity listed by NEEP, in BTU/h (COP in brackets), size 12,000.
Outdoor temperatureHeat Xtreme Pro R-454B23 SEERHeat Xtreme Pro R-410ADA2518 SEER
8.3 °C16,000 (3.35)12,300 (3.08)15,613 (2.95)13,941 (3.55)not listed
−8.3 °C12,800 (1.75)10,100 (1.95)13,112 (2.11)9,921 (2.31)not listed
−15 °C11,500 (1.80)9,600 (1.85)12,000 (1.80)8,000 (2.39)not listed
−20 °C—9,300 (1.79)———
−30 °C5,900 (1.25)————
At −15 °C, share of rated capacity (ENERGY STAR)96% (11,500)70% (8,400)100% (12,000)67% (8,000)not listed

NEEP lists data at 47 °F (8.3 °C), 17 °F (−8.3 °C), 5 °F (−15 °C) and at the coldest point the manufacturer declares (−4 °F = −20 °C, −22 °F = −30 °C). Some −15 °C figures are higher than the −8.3 °C ones: these are the values as NEEP publishes them. The 18 SEER is listed with neither NEEP nor ENERGY STAR.

Montreal’s winter

Montreal’s winter in numbers, against those published points.

Environment and Climate Change Canada 1991–2020 climate normals, Montréal-Trudeau station.

−13.5 °Caverage daily low in January
12 nightsbelow −20 °C, on average each year
0.21 nightbelow −30 °C per year, about one every five years
−31.8 °Cthe coldest of 1991–2020 (January 27, 1994)

Typical January nights

Average low of −13.5 °C: series with a point listed at −15 °C or colder have a figure for these nights.

Series with a published figure:Heat Xtreme Pro R-454B23 SEERHeat Xtreme Pro R-410ADA25

The ≈ 12 nights below −20 °C

Only series with a point listed at −20 °C or colder have a figure for these nights.

Series with a published figure:Heat Xtreme Pro R-454B23 SEER

The rare nights below −30 °C

About one night every five years. Only one series has a point listed at that temperature.

Series with a published figure:Heat Xtreme Pro R-454B

Source: ECCC, Canadian Climate Normals 1991–2020, MONTREAL TRUDEAU (AIRPORT), climate ID 7025250, page updated August 10, 2026, read October 14, 2026. Matching with NEEP points: AirGreen calculation.

Same head, different outdoor unit

The DA25 and the Heat Xtreme Pro R-410A share the same indoor unit. The difference is outside.

ENERGY STAR and NEEP list both series with the same DIRM-xxHP-WM wall head, and the Direct Air brochures give it the same dimensions. The outdoor unit is what changes the cold-weather figures.

SizeWall headDA25
at −15 °C
Heat Xtreme Pro R-410A
at −15 °C
GapLogisVert
DA25 · HXP
9,000DIRM-09HP-WM7,500 BTU/h10,600 BTU/h+41%— · —
12,000DIRM-12HP-WM8,000 BTU/h12,000 BTU/h+50%$450 · $1,200
18,000DIRM-18HP-WM11,300 BTU/h18,000 BTU/h+59%$745 · $1,800
24,000DIRM-24HP-WM15,500 BTU/h25,000 BTU/h+61%$810 · $2,544

What this wall head does, as Direct Air describes it

12-speed fan · Sleep mode · Turbo mode · Eco mode · Left or right drain · Refrigerant leak detector · Biofilter · Shutter position memory · Anti-corrosion coating of the fins · “Follow me” function · Self-cleaning · Motion detector · Humidity sensor for increased comfort · Optional Wi-Fi.

Heat Xtreme Pro (July 2022) and DA25 (March 2023) brochures. Some features are marked “optional” there: we confirm the list with the quote. The DA25 brochure writes DIRM-xxDA25-WM for the same head; ENERGY STAR and NEEP list it as DIRM-xxHP-WM.

Installation

What each series asks of the installer, size by size.

Values from the Direct Air brochures and spec pages. “Not published”: the brand does not give the figure; we confirm it with Direct Air before quoting.

12,000 BTU/hHeat Xtreme Pro R-454B23 SEERHeat Xtreme Pro R-410ADA2518 SEER
Power supplynot published208–230 V, 1 ph, 60 Hz208/230 V, 1 ph, 60 Hz208/230 V, 1 ph, 60 Hz208–230 V, 1 ph, 60 Hz
Max. breaker or fusenot published15 A15 A15 A25 A
Line set, liquid · gas (in.)not published1/4 · 3/81/4 · 1/21/4 · 1/21/4 · 3/8
Max. line lengthnot published20 m25 m25 mnot published
Max. height differencenot published10 m10 m10 mnot published
Refrigerant chargenot published1,160 g1,180 g1,080 gnot published
Outdoor soundnot published53 dB(A)56 dB(A)53.5 dB(A)54 dB(A)
Model numbers

A model number on a rating plate or a quote? Find the unit.

Direct Air does not publish what its model numbers mean. This table links each number to the unit, its AHRI number and its product page.

20 models
SeriesSizeOutdoorIndoorAHRIPage
Heat Xtreme Pro R-454B6,000DIRM4-06HXPRO28-1ZDIRM4-06HP-WM216571371View
Heat Xtreme Pro R-454B18,000DIRM4-18HXPRO28-1ZDIRM4-18HP-WM216571374View
Heat Xtreme Pro R-454B24,000DIRM4-24HXPRO28-1ZDIRM4-24HP-WM216571375View
Heat Xtreme Pro R-454B12,000DIRM4-12HXPRO28-1ZDIRM4-12HP-WM216571373View
Heat Xtreme Pro R-454B9,000DIRM4-09HXPRO28-1ZDIRM4-09HP-WM216571372View
23 SEER18,000DIRH-18HP23-DKODIRH-18HP23-DKI207583108View
23 SEER12,000DIRH-12HP23-DKODIRH-12HP23-DKI207583107View
Heat Xtreme Pro R-410A24,000DIRM-24HXPRO28-1ZDIRM-24HP-WM207743727View
Heat Xtreme Pro R-410A18,000DIRM-18HXPRO28-1ZDIRM-18HP-WM207743726View
Heat Xtreme Pro R-410A12,000DIRM-12HXPRO28-1ZDIRM-12HP-WM207743725View
Heat Xtreme Pro R-410A9,000DIRM-09HXPRO28-1ZDIRM-09HP-WM207743724View
Heat Xtreme Pro R-410A6,000DIRM-06HXPRO28-1ZDIRM-06HP-WM207743723View
DA2524,000DIRM-24DA25-1ZDIRM-24HP-WM207743722View
DA2518,000DIRM-18DA25-1ZDIRM-18HP-WM207743721View
DA2512,000DIRM-12DA25-1ZDIRM-12HP-WM207743720View
DA259,000DIRM-09DA25-1ZDIRM-09HP-WM207743719View
18 SEER24,000DIR-24HP17-DKODIR-24HP17-DKI10306423View
18 SEER18,000DIR-18HP17-DKODIR-18HP17-DKI10306422View
18 SEER12,000DIR-12HP17DKO-230DIR-12HP17DKI-230203490395View
18 SEER9,000DIR-09HP17DKO-230DIR-09HP17DKI-230203490394View

Numbers from the airgreen.ca product pages, identical to ENERGY STAR’s.

R-410A · R-454B

Two Heat Xtreme Pro versions, two refrigerants.

Heat Xtreme Pro R-410A

2,088 GWP

Coldest point listed by NEEP: −15 °C. Published warranty: 10 years compressor, 5 years parts and labour (July 2022 brochure).

See the R-410A →

Heat Xtreme Pro R-454B

470 GWP

Coldest point listed by NEEP: −30 °C. DIRM4 models, listed with ENERGY STAR; Direct Air has not yet published a brochure or warranty for them.

See the R-454B →

GWP: global warming potential, as listed by ENERGY STAR (read October 14, 2026).

Questions

What people ask us, and what the sources say.

Which DIRECT AIR wall heat pump still heats at −30 °C?

The Heat Xtreme Pro R-454B is the only DIRECT AIR wall series with a heating point listed at −30 °C (−22 °F) by NEEP: from 3,200 BTU/h (6,000) to 11,900 BTU/h (24,000) at most. With NEEP, the 23 SEER stops at −20 °C; the DA25 and Heat Xtreme Pro R-410A at −15 °C. The 18 SEER is listed with neither ENERGY STAR nor NEEP.

Are the 6,000 and 9,000 BTU/h wall units eligible for LogisVert?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) requires a rated cooling capacity of at least 12,000 BTU/h. No 6,000 or 9,000 BTU/h DIRECT AIR wall unit is on the October 14, 2026 list. The full rules are on the DIRECT AIR page.

Is the 18 SEER ENERGY STAR certified?

No. As of October 26, 2026, its four AHRI numbers are listed with neither ENERGY STAR nor NEEP. It therefore has no published cold-weather heating figure and is not eligible for LogisVert. Its 2022 brochure states heating down to −20 °C.

Does a DIRECT AIR wall unit come with Wi-Fi?

The Heat Xtreme Pro brochure says “Wi-Fi ready” and the DA25 brochure “Optional Wi-Fi”. The 18 SEER brochure does not mention it. No brochure is published yet for the R-454B: we confirm the module with the quote.

Why do the DA25 and the Heat Xtreme Pro share the same indoor unit?

ENERGY STAR and NEEP list both series with the DIRM-xxHP-WM wall head, and the brochures give it the same dimensions. The outdoor unit is what differs: at 12,000 BTU/h, the Heat Xtreme Pro outdoor unit delivers 12,000 BTU/h at −15 °C, the DA25 outdoor unit 8,000 BTU/h.

Is there a 115 V DIRECT AIR wall unit?

The 18 SEER brochure (2022) lists 115 V for the 9,000 BTU/h model. The model on our page carries the “-230” suffix: we confirm its voltage with Direct Air before quoting. The DA25 and Heat Xtreme Pro R-410A are 208/230 V according to their brochures.

AirGreen × DIRECT AIR

Your DIRECT AIR wall unit, chosen for your winter and installed by AirGreen.

Tell us the room, its size and your current heating: we suggest the series and size, with the AHRI number and the indicative LogisVert amount on the quote.

Sold and installed by AirGreen · RBQ 5645-9605-01

Sources, checked on October 26, 2026

  1. NEEP Cold Climate Air Source Heat Pump list, listings by AHRI number, read October 14, 2026 and rechecked October 26, 2026.
  2. ENERGY STAR, Certified Air-Source Heat Pumps (data.energystar.gov, dataset w7cv-9xjt), Canadian market, read October 14, 2026 and rechecked October 26, 2026.
  3. Hydro-Québec, LogisVert eligible heat pump list (owner, existing home) of October 14, 2026; LogisVert residential participation guide, version 1.10, September 15, 2026.
  4. Direct Air brochures: Heat Xtreme Pro (July 2022), DA25 (March 2023), 18 SEER (June 2022); 23 SEER page on directairhvac.com, read October 14, 2026.
  5. ECCC, Canadian Climate Normals 1991–2020, Montréal-Trudeau (7025250), read October 14, 2026.
  6. airgreen.ca product pages (metafields), reread October 26, 2026.

LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote. Page updated October 26, 2026.