The DIRECT AIR space at AirGreenSold and installed by AirGreen
Ducted: a hidden head, and the pressure your ducts need.
The range has 14 listings: horizontal or vertical from 9,000 to 18,000 BTU/h, and a 24,000 for both positions, with the Heat Xtreme Pro or DA25 outdoor unit. The choice comes down to the static pressure your ducts require: from 0.16 to 0.64 in. wc depending on size. With the Heat Xtreme Pro, NEEP lists a −30 °C point for every size.
Horizontal, vertical, or the 24,000 that does both.
The horizontal (DUH) and vertical (DUV) versions have the same ENERGY STAR and NEEP figures and the same dimensions; only the position changes. The air intake can be at the back or the top, per the brochures.
Horizontal
DIRM-xxHP-DUH
9,000 · 12,000 · 18,000 BTU/h
Lying in a dropped ceiling. Body 200 mm (9,000, 12,000) or 210 mm (18,000) high.
Vertical
DIRM-xxHP-DUV
9,000 · 12,000 · 18,000 BTU/h
Standing in a closet or mechanical room. Same dimensions as the horizontal version.
24,000, both
DIRM-24HP-DU
24,000 BTU/h
A single model for both positions. Body of 1,092 × 762 × 254 mm, and the highest static pressure: up to 0.64 in. wc.
The figure that decides the size: 0.16, 0.40 or 0.64 in. wc.
A ducted unit has to push air through your whole duct system. Enter the static pressure calculated for your ducts, and the airflow needed if you know it.
Your ducts
Calculating…
With a ducted head, NEEP lists a colder point for the same outdoor unit than with the wall head.
| Outdoor unit | With the wall head coldest point listed by NEEP | With the ducted head coldest point listed by NEEP |
|---|---|---|
| Heat Xtreme Pro 9,000 DIRM-09HXPRO28-1Z | −15 °C 10,600 BTU/h max | −30 °C 5,000 BTU/h max · COP 1.05 |
| DA25 9,000 DIRM-09DA25-1Z | −15 °C 8,581 BTU/h max | −25 °C 3,900 BTU/h max · COP 1.14 |
| Heat Xtreme Pro 12,000 DIRM-12HXPRO28-1Z | −15 °C 12,000 BTU/h max | −30 °C 5,500 BTU/h max · COP 1.07 |
| DA25 12,000 DIRM-12DA25-1Z | −15 °C 8,000 BTU/h max | −25 °C 6,200 BTU/h max · COP 1.14 |
| Heat Xtreme Pro 18,000 DIRM-18HXPRO28-1Z | −15 °C 18,000 BTU/h max | −30 °C 9,000 BTU/h max · COP 1.50 |
| DA25 18,000 DIRM-18DA25-1Z | −15 °C 11,300 BTU/h max | −25 °C 6,500 BTU/h max · COP 1.75 |
| Heat Xtreme Pro 24,000 DIRM-24HXPRO28-1Z | −15 °C 25,000 BTU/h max | −30 °C 11,000 BTU/h max · COP 1.24 |
| DA25 24,000 DIRM-24DA25-1Z | −15 °C 17,500 BTU/h max | −25 °C 10,500 BTU/h max · COP 1.51 |
NEEP lists each outdoor + head combination separately (points rechecked October 26, 2026). With the wall head, having no colder point does not mean the unit stops: the brochures state heating down to −35 °C (Heat Xtreme Pro) and −25 °C (DA25).
Same ducted unit, two outdoor units: size by size.
Figures for the horizontal version; the vertical one is the same. At 18,000, the DA25 offers more static pressure (0.40 in. wc) than the Heat Xtreme Pro (0.16).
| 9,000 BTU/h | Heat Xtreme Pro | DA25 |
|---|---|---|
| Coldest point listed by NEEP | −30 °C 5,000 BTU/h max · COP 1.05 | −25 °C 3,900 BTU/h max · COP 1.14 |
| At −15 °C (ENERGY STAR rated) | 10,800 BTU/h · max 10,800 | 8,000 BTU/h · max 8,000 |
| SEER2 · HSPF2 | 20.2 · 12.0 | 19.2 · 10.2 |
| ENERGY STAR cold climate | yes | yes |
| LogisVert | not on the list | not on the list |
| Indoor sound H · M · L | 33 • 30.5 • 27 dB(A) | 33.5 • 28.5 • 27 dB(A) |
| Airflow H · M · L | 353 • 282 • 176 CFM | 353 • 282 • 176 CFM |
| Head (W × D × H) · weight | 700 × 506 × 200 mm · 17.7 kg | 700 × 506 × 200 mm · 17.7 kg |
| Outdoor sound · breaker | 54.5 dB(A) · 15 A | 53 dB(A) · 15 A |
| 12,000 BTU/h | Heat Xtreme Pro | DA25 |
|---|---|---|
| Coldest point listed by NEEP | −30 °C 5,500 BTU/h max · COP 1.07 | −25 °C 6,200 BTU/h max · COP 1.14 |
| At −15 °C (ENERGY STAR rated) | 12,100 BTU/h · max 12,100 | 8,400 BTU/h · max 8,400 |
| SEER2 · HSPF2 | 19.5 · 10.0 | 19.0 · 10.3 |
| ENERGY STAR cold climate | yes | yes |
| LogisVert | $1,272 | not on the list |
| Indoor sound H · M · L | 40 • 31.5 • 26.5 dB(A) | 38 • 34.5 • 31 dB(A) |
| Airflow H · M · L | 353 • 282 • 176 CFM | 353 • 282 • 176 CFM |
| Head (W × D × H) · weight | 700 × 506 × 200 mm · 17.8 kg | 700 × 506 × 200 mm · 17.8 kg |
| Outdoor sound · breaker | 56 dB(A) · 15 A | 53.5 dB(A) · 15 A |
| 18,000 BTU/h | Heat Xtreme Pro | DA25 |
|---|---|---|
| Coldest point listed by NEEP | −30 °C 9,000 BTU/h max · COP 1.50 | −25 °C 6,500 BTU/h max · COP 1.75 |
| At −15 °C (ENERGY STAR rated) | 17,700 BTU/h · max 17,700 | 13,000 BTU/h · max 13,000 |
| SEER2 · HSPF2 | 18.0 · 9.5 | 20.0 · 10.6 |
| ENERGY STAR cold climate | yes | no |
| LogisVert | $1,800 | $630 |
| Indoor sound H · M · L | 40 • 37.5 • 35 dB(A) | 43 • 40.5 • 38 dB(A) |
| Airflow H · M · L | 529 • 450 • 371 CFM | 529 • 450 • 371 CFM |
| Head (W × D × H) · weight | 878 × 725 × 210 mm · 25.1 kg | 880 × 725 × 210 mm · 25.1 kg |
| Outdoor sound · breaker | 59 dB(A) · 25 A | 58 dB(A) · 25 A |
| 24,000 BTU/h | Heat Xtreme Pro | DA25 |
|---|---|---|
| Coldest point listed by NEEP | −30 °C 11,000 BTU/h max · COP 1.24 | −25 °C 10,500 BTU/h max · COP 1.51 |
| At −15 °C (ENERGY STAR rated) | 27,000 BTU/h · max 27,000 | 20,000 BTU/h · max 20,000 |
| SEER2 · HSPF2 | 19.2 · 10.5 | 19.0 · 11.2 |
| ENERGY STAR cold climate | yes | yes |
| LogisVert | $2,520 | $2,400 |
| Indoor sound H · M · L | 44 • 40 • 35.5 dB(A) | 44 • 41 • 37 dB(A) |
| Airflow H · M · L | 775 • 693 • 435 CFM | 775 • 693 • 435 CFM |
| Head (W × D × H) · weight | 1,092 × 762 × 254 mm · 41 kg | 1,092 × 762 × 254 mm · 41 kg |
| Outdoor sound · breaker | 62 dB(A) · 35 A | 60 dB(A) · 30 A |
NEEP and ENERGY STAR rechecked October 26, 2026; sound, airflow, dimensions and breaker: Heat Xtreme Pro (July 2022) and DA25 (March 2023) brochures; LogisVert: October 14, 2026 list.
- Built-in drain pump
- Flexible air intake (back or top)
- Filter
- Variable static pressure control
- Remote control and programmable wall control included
- Electric duct heater optional
- Available for both horizontal and vertical installations
Heat Xtreme Pro (July 2022) and DA25 (March 2023) brochures, duct unit page.
What people ask us, and what the sources say.
Horizontal or vertical: how to choose?
By the space: horizontal in a dropped ceiling, vertical in a closet or mechanical room. Both versions have the same ENERGY STAR and NEEP figures and the same dimensions. The 24,000 is a single model for both positions.
What static pressure do they offer?
Per the brochures: 0 to 0.16 in. wc for the 9,000 and 12,000 of both series and the 18,000 Heat Xtreme Pro; 0 to 0.40 in. wc for the 18,000 DA25; 0 to 0.64 in. wc for the 24,000 units.
Why is the 12,000 DA25 ducted unit not eligible for LogisVert?
It is not on the October 14, 2026 list. ENERGY STAR rates it at 11,500 BTU/h in cooling, under the program’s 12,000 BTU/h threshold. The 12,000 Heat Xtreme Pro ducted unit, certified at 12,000 BTU/h, qualifies: $1,272.
Can electric heat be added?
The brochures offer an optional electric duct heater for the duct units. We size it and connect it with the ducted unit.
Down to what temperature does it heat?
With the Heat Xtreme Pro outdoor unit, NEEP publishes a −30 °C point for each size (5,000 to 11,000 BTU/h at most). With the DA25 outdoor unit, the coldest point is −25 °C (3,900 to 10,500 BTU/h).
Your ducted unit, hidden and connected to your ducts by AirGreen.
We calculate your ducts’ pressure and airflow, choose the position and size, then quote with the AHRI number and the indicative LogisVert amount.
Sold and installed by AirGreen · RBQ 5645-9605-01Sources, checked on October 26, 2026
- NEEP listings of DIRECT AIR AHRI systems by head (cassette, ducted, console, floor-ceiling) and of the matching wall systems, read October 14, 2026 and rechecked October 26, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps (data.energystar.gov, dataset w7cv-9xjt), Canadian market, read October 14, 2026 and rechecked October 26, 2026.
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home) of October 14, 2026; LogisVert residential participation guide, version 1.10, September 15, 2026.
- Direct Air Heat Xtreme Pro brochure, French and English, printed July 2022 (in our files).
- Direct Air DA25 brochure, French and English, printed March 2023 (in our files).
- airgreen.ca product pages (metafields), reread October 26, 2026.
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote. Page updated October 26, 2026.