Project

Installation of an ELIOS R454B electric furnace in Saint-Amable, on Montreal’s South Shore

In Saint-Amable, AirGreen installs an ELIOS R454B electric furnace in a tight basement, with a metal base, custom plenum, sealed ducts, and service access carefully preserved.

By AirGreen Climatisation & Chauffage Admin18 min read
Installation of an ELIOS R454B electric furnace in Saint-Amable, on Montreal’s South Shore
Installation of an ELIOS R454B electric furnace in Saint-Amable, on Montreal’s South Shore
Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

A custom central installation in a narrow basement, with complete ductwork adaptation

At Saint-Amable, our AirGreen team installed an ELIOS electric furnace compatible with a central heat pump using R454B in a particularly narrow mechanical space. The site photograph shows a vertical configuration integrated between open framing and an existing wall, with very little side clearance. In this type of environment, project quality depends as much on equipment selection as on duct fabrication, connection sealing, and accessibility for future maintenance work.

The indoor unit is installed on a raised metal base. Above the cabinet, several sections of galvanized sheet metal were adapted to connect to the existing duct system. The upper transition, sealed joints, and vertical plenum show that the installation required custom sheet-metal work rather than a simple direct connection.

The basement also presents a significant constraint: the passage remains narrow around the unit. On the left, the wood framing is open; on the right, the existing wall and its finish reduce the workspace. We therefore had to organize each step precisely in order to position the new furnace, fabricate the transitions, preserve circulation in the basement, and maintain reasonable access to the service panels.

This project clearly illustrates what distinguishes a true professional HVAC installation from an improvised replacement. New equipment can deliver its full performance only if the air distribution system, static pressure, auxiliary heating, controls, and refrigeration circuit are all configured as a cohesive system.

What the installation in Saint-Amable shows

The visible installation includes several important technical elements:

  • an ELIOS indoor unit in a vertical position;
  • a fabricated metal base to support and align the unit;
  • a vertical supply plenum;
  • metal transitions adapted to the existing system;
  • sealed duct joints;
  • an installation integrated into a very narrow mechanical corridor;
  • a front space reserved for technical access;
  • a connection designed for a central heat pump to the R454B.

The unit's exact width and capacity cannot be confirmed from the photo alone. The Central-Elios range includes several combinations from 24,000 to 60,000 BTU, with interior dimensions that vary by model. The 24,000 BTU units are approximately 17.52 inches wide, while the 30,000 and 36,000 BTU versions are approximately 21.02 inches wide. The 48,000 and 60,000 BTU units are approximately 24.49 inches wide.

This variation in dimensions is critical in an installation like this one. A few extra inches may require a more extensive reconstruction of the plenum, reduce clearance, or prevent the panels from opening.

Why install a central electric furnace instead of a wall-mounted system?

A central electric furnace connected to a heat pump can distribute heating and cooling throughout the home using a duct network.

For a property already equipped with a forced-air system, this solution can offer several advantages:

  • reuse of some of the existing ducts;
  • uniform heating between rooms;
  • central air conditioning;
  • control from a main thermostat;
  • the possibility of integrating auxiliary electric heating;
  • no visible wall-mounted units in living areas;
  • centralized air filtration.

However, the suitability of this solution depends on the condition of the ducts. A system that is too small, unbalanced, or highly leaky can limit performance even with a recent heat pump.

In this Saint-Amable project, the priority was therefore not only to fit the ELIOS unit into the available space. We also had to ensure a functional air transition between the cabinet and the existing system.

Plenum fabrication: a central step in the project

The large metal duct visible above the unit forms the supply plenum. This section receives the air treated by the furnace and directs it to the various distribution ducts.

The connection between a new unit and an existing system is almost never perfectly aligned. The cabinet dimensions, air outlet position, and available height often differ from those of the old system.

We must then fabricate one or more transitions that allow for a gradual change from one dimension to another.

A well-designed transition must:

  • limit turbulence;
  • maintain airflow;
  • reduce noise;
  • avoid overly abrupt changes in cross-section;
  • remain rigid;
  • be airtight;
  • remain accessible for maintenance.

In the photograph, the different sections of the plenum are clearly visible. The upper connection was adapted to the existing geometry, while the joints were sealed with appropriate metal tape.

Why is ductwork tightness so important?

A leak in a ductwork system may seem minor, especially when it is located in a basement. However, it can considerably reduce the amount of air that reaches the rooms.

A leak on the supply side can release heated or conditioned air into the mechanical room. A leak on the return side can draw in dust, moisture, or untreated air.

Possible consequences include:

  • an increase in operating time;
  • less comfortable rooms;
  • higher air noise;
  • increased electricity consumption;
  • an imbalance between floors;
  • a buildup of dust inside the unit;
  • a static pressure different from the intended level.

In a Saint-Amable electric furnace installation, sealing the connections is therefore not merely an aesthetic finishing touch. It directly affects the system’s operation.

A metal base designed to support and align the unit

The furnace rests on a rectangular galvanized sheet-metal base. This base properly aligns the cabinet with the ductwork while keeping it above the floor.

It can also serve as a transition for the return air, depending on the system configuration.

A poorly constructed base can cause:

  • vibrations;
  • cabinet deformation;
  • air leaks;
  • misalignment;
  • noise transmitted to the floor;
  • difficulty removing the panels.

We therefore check that the unit is level, that its weight is properly distributed, and that the air openings are not obstructed.

In a tight basement, the base must also respect the available clearance. An excessive projection could become an obstacle or complicate future work.

Static pressure: an invisible but decisive factor

Static pressure represents the resistance the fan must overcome to move air through the ductwork.

It depends in particular on:

  • the duct dimensions;
  • the length of the ductwork;
  • the number of elbows;
  • the type of filter;
  • the condition of the grilles;
  • transitions;
  • dampers;
  • the indoor coil;
  • fan speed.

Excessive pressure can reduce airflow, increase noise, and place unnecessary strain on the motor.

During commissioning, we do not limit ourselves to checking whether air is coming out of the grilles. We must confirm that the airflow matches the needs of the heat pump and furnace.

A central system may appear to be operating properly while receiving insufficient airflow. Symptoms sometimes appear later: protection cycles, discomfort, frost, or abnormal energy consumption.

A central system designed for cold climates

Central-Elios documentation presents a range of central systems designed to operate in heating mode down to -30 °C.

The manufacturer also indicates that systems can maintain 69% to 76% of their rated capacity at -30 °C, depending on the model and operating conditions. The brochure also mentions capacity of up to 100% of the rated value at -20 °C.

This feature is particularly relevant in Saint-Amable and on the South Shore, where a heat pump must cope with extended periods of cold weather.

However, it is important to distinguish operating capacity from the capacity required to heat a particular building.

A heat pump can continue operating at -30 °C without necessarily covering all of the home's heat loss on its own. That is why load calculations and auxiliary heating selection remain essential.

Inverter technology and indoor comfort

The Central-Elios line uses a variable-speed Inverter compressor.

This technology allows the outdoor unit to modulate its output instead of operating only in on-off mode.

When demand is low, the compressor can slow down. When the outdoor temperature drops or the home requires more heating, it can gradually increase its capacity.

Proper modulation helps to:

  • reduce temperature fluctuations;
  • extend cycles;
  • limit frequent starts;
  • improve humidity control;
  • reduce certain operating noises;
  • adjust consumption to actual demand.

The brochure indicates efficiency of up to 18.3 TRÉS2 and a CPSC2 of up to 8.6, depending on the selected combination.

These maximum values should not be applied automatically to all models. Exact performance varies according to the selected indoor and outdoor capacity.

A successful ELIOS R454B installation relies on much more than the furnace itself

The role of auxiliary electric heating

The electric furnace can incorporate an auxiliary heating coil designed to supplement the heat pump.

ELIOS documentation indicates that elements ranging from 3 to 25 kW are available depending on the configuration.

Electric heating can assist:

  • during extreme temperatures;
  • during defrost cycles;
  • if demand exceeds the available capacity;
  • for a rapid temperature recovery;
  • in emergency heating mode;
  • if the outdoor unit is temporarily unavailable.

The electric heating coil's capacity must not be chosen at random.

An undersized element may fail to maintain the temperature during a cold snap. An oversized element may require a larger electrical service, increase the power draw, and operate unnecessarily if the controls are improperly adjusted.

We must therefore analyze:

  • the building's heat losses;
  • the heat pump's low-temperature capacity;
  • the electrical panel;
  • circuit breakers;
  • conductor sizing;
  • the control strategy;
  • the auxiliary heating stages.

The electrical compatibility of the fan coil

The brochure indicates that the Central-Elios fan coil may be compatible with two voltages and may operate at 115 V in certain configurations. This feature may simplify some projects by avoiding the addition of a dedicated 230 V circuit for the indoor unit itself.

This does not mean that the entire system operates solely on 115 V. The outdoor unit and auxiliary electrical components have their own power supply requirements.

Each component must be connected according to its nameplate.

We check, in particular:

  • voltage;
  • number of phases;
  • minimum circuit ampacity;
  • maximum protection;
  • the disconnect type;
  • grounding;
  • the panel capacity.

R454B: a new-generation refrigerant

The system uses the refrigerant R454B, classified as A2L.

This classification means that the product has low flammability and requires appropriate work procedures.

Technicians must use compatible tools, follow ventilation requirements, and carefully check the tightness of the connections.

The ELIOS documentation mentions an integrated leak detection system. If a leak is detected, the unit can stop the compressor, maintain airflow, and trigger a service alert.

This function provides additional protection, but it does not replace a rigorous refrigeration installation.

The leak-tightness test and evacuation

Before startup, the refrigeration lines must be checked.

A professional procedure generally includes:

  1. inspection of the connections;
  2. pressurization with dry nitrogen;
  3. checking for pressure losses;
  4. leak detection;
  5. evacuation;
  6. checking the vacuum level;
  7. a holding test;
  8. opening the valves;
  9. validation of operating parameters.

The purpose of evacuation is to remove air and moisture from the system.

Poor evacuation can cause:

  • oil contamination;
  • loss of efficiency;
  • abnormal pressures;
  • premature compressor deterioration;
  • intermittent problems that are difficult to diagnose.

This part of the work is invisible once the panels are closed, but it is among the most important installation steps.

Refrigerant line dimensions

Central-Elios documentation indicates connections of:

  • 3/8 in. for the liquid line;
  • 3/4 in. for the gas line.

These diameters are common to the five capacities presented in the brochure.

The maximum line-set length varies by model:

  • up to 164 ft for the 24,000 and 30,000 BTU configurations;
  • up to 246 ft for the 36,000, 48,000, and 60,000 BTU configurations.

The maximum height difference also varies from 82 to 98.4 ft.

These limits offer considerable flexibility, but they do not mean that a long line set can be installed without calculations. Refrigerant charge, slope, oil return, and manufacturer requirements must be respected.

Drainage in cooling mode

When the heat pump operates in cooling mode, the indoor coil removes moisture from the air.

This water must be evacuated through a properly designed drain.

Depending on capacity, the brochure indicates moisture removal ranging approximately from 2.05 to 5.87 liters per hour.

An improperly installed drain can cause:

  • an overflow;
  • water infiltration into the basement;
  • odors;
  • deposits;
  • a blockage;
  • damage to materials;
  • a safety shutdown.

The drain must have an adequate slope and remain accessible for cleaning.

In a basement such as the one in Saint-Amable, a leak can spread beneath floor coverings before it is noticed. We therefore pay particular attention to the drainage path.

Why the filter must remain easily accessible

System performance depends directly on filter cleanliness.

A dust-laden filter increases resistance in the system. The fan must then work harder, while airflow decreases.

Possible consequences include:

  • reduced comfort;
  • increased noise;
  • overheating of the elements;
  • frost on the coil;
  • increased consumption;
  • an extended operating time.

In a narrow mechanical corridor, access to the filter must be planned before the walls are closed or storage is added.

The owner should never be required to dismantle a section of ductwork to replace a regular filter.

Mistakes to avoid in a narrow central installation

Closing off the corridor with a partition too close to the unit

Service panels must remain accessible.

Reducing the plenum size to save space

Excessive reduction can create a restriction and increase noise.

Using tape not designed for HVAC ducts

Ordinary adhesives often come loose under the effects of heat and dust.

Neglecting the air return

A well-built supply plenum does not compensate for an undersized return.

Storing objects against the unit

The panels, filter, and connections must remain unobstructed.

Closing several registers in the house

This can increase static pressure and reduce overall airflow.

Choosing the capacity solely based on the old unit

The old furnace may have been oversized or poorly suited to the building.

The thermostat and controls

The Central-Elios line can be used with a compatible controller or a touchscreen thermostat, depending on the configuration.

The documentation specifically presents:

  • the Wi-Fi-compatible KJRSAALW1 controller;
  • the Wi-Fi-compatible ST1S42RW1 thermostat.

The control selected must be able to manage the following properly:

  • the heat pump;
  • auxiliary heating;
  • ventilation;
  • defrost sequences;
  • alerts;
  • emergency modes;
  • the temperature setpoint.

A generic thermostat that is improperly configured can limit modulation or activate electric heating too frequently.

Certifications and eligibility for financial assistance

The brochure states that the five combinations presented are certified ENERGY STAR V6.1 and ENERGY STAR Cold Climate.

This certification is relevant for homeowners comparing performance and verifying eligibility for financial assistance programs.

However, general certification does not automatically guarantee a grant amount.

The following must be confirmed:

  • the exact indoor model;
  • the exact outdoor model;
  • the certified combination;
  • the AHRI number or official reference;
  • heating capacity;
  • the building type;
  • the installation date;
  • the program rules at the time of application.

At AirGreen, we avoid advertising financial assistance before validating the complete combination.

Warranties for the Central-Elios line

The documentation presents a one-year limited warranty on parts and a five-year warranty on the compressor and indoor coil.

A ten-year extended warranty may be available for parts, the compressor, and the indoor coil. An optional ten-year labor warranty may also be offered by a third party.

Registration conditions and exclusions should always be verified.

The owner should keep:

  • the invoice;
  • model numbers;
  • serial numbers;
  • the commissioning report;
  • warranty documentation;
  • maintenance records;
  • the grant documents.

A representative installation of projects completed on the South Shore

This Saint-Amable project presents several constraints that we regularly encounter in Longueuil, Boucherville, Sainte-Julie, Varennes, and other areas of the South Shore.

Basements may include:

  • narrow passageways;
  • old ductwork;
  • open framing;
  • limited ceiling heights;
  • uneven walls;
  • networks modified over the years;
  • limited service space.

In Montreal, the constraints are often related to low basements and row houses. In Laval and on the North Shore, we frequently encounter long duct networks or units installed in shared spaces.

In every case, we must adapt the equipment to the building rather than force the building to accept a standard configuration.

HVAC maintenance adapted to the configuration

Periodic HVAC maintenance helps verify that the installation continues to operate according to the original settings.

The homeowner can monitor:

  • the condition of the filter;
  • unusual noises;
  • odors;
  • the presence of water;
  • the airflow at the registers;
  • the codes displayed on the thermostat;
  • temperature fluctuations;
  • the electricity consumption.

During a professional inspection, we can check:

  • the static pressure;
  • the airflow;
  • the blower;
  • the electrical components;
  • the coil;
  • the drain;
  • the connections;
  • the sensors;
  • the controls;
  • the outdoor heat pump;
  • the auxiliary heating sequences.

The result: a central furnace integrated into the building, not simply placed in the basement

This installation of an ELIOS R454B electric furnace in Saint-Amable demonstrates the importance of sheet metal work, planning, and precision.

The main challenge of the project was the limited width of the mechanical corridor. The unit had to be installed, access preserved, transitions rebuilt, and adequate airflow ensured without unnecessarily encroaching on the passageway.

The vertical plenum, metal base, and sealed connections made it possible to integrate the new system into the existing network. The unit can now circulate heated or cooled air throughout the house while remaining accessible for future maintenance work.

At AirGreen, we carry out this type of HVAC installation in Saint-Amable, Montreal, Laval, Longueuil, on the North Shore, and throughout the South Shore. Our approach consists of assessing the building as a whole: capacity, ductwork, electrical systems, refrigerant, drainage, controls, and technical access.

A modern furnace can only provide lasting comfort if all these elements are addressed with the same level of care.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment