Project

Installation of a Fujitsu AIRSTAGE wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension

AirGreen installs a Fujitsu AIRSTAGE wall unit in Villeray–Saint-Michel–Parc-Extension . Precise integration, gravity drainage, 4-season comfort and simplified HVAC maintenance for Montreal, Laval, Longueuil, North Shore and South Shore.

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Fujitsu AIRSTAGE wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Installation of a Fujitsu AIRSTAGE wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

A Fujitsu wall head integrated precisely into a small living room

At AirGreen , we transform the tightest spaces in Greater Montreal into zones of controlled comfort. This project in Villeray–Saint-Michel–Parc-Extension features the installation of a Fujitsu AIRSTAGE wall-mounted heat pump , installed at the top of a corner wall. The goal: to provide quiet, reliable, and energy-efficient four-season heating and cooling without encroaching on existing furnishings.

Project context and constraints

The client wanted to equip a multi-purpose room that could be used as a small office and a spare bedroom. The available space was located near a corner , with an open shelf at the bottom and a close ceiling area . These elements required:

  • precise clearances to ensure air intake and flow direction;

  • the shortest possible refrigerant connection passage to preserve efficiency;

  • a clean and secure gravity condensate drainage , invisible in the room.

Why the Fujitsu AIRSTAGE wall head?

Fujitsu's AIRSTAGE range is distinguished by its fine modulation , acoustic sobriety and electronic control that quickly stabilizes the temperature. For a compact space, it's a relevant choice: the discreet front integrates into any decor and the wide swing (shutter) distributes the air along the length of the room. The Fujitsu logo and AIRSTAGE screen printing guarantee multi-zone compatibility where applicable, while remaining perfectly suited for single-zone use.

What we are aiming for with this type of device:

  • smoothed consumption thanks to the Inverter;

  • very low noise level indoors, ideal for teleworking and resting;

  • a precision of instruction which avoids jolts and improves perceived comfort .

Positioning study: the key to consistent distribution

The wall head is installed at the top of the wall , at a controlled distance from the ceiling in order to prevent the recirculation of hot air and to allow the sensor to work in real environment. We have:

  1. validated the absence of immediate obstacles (curtains, columns, falling beams);

  2. adjusted the height so that the swing can direct the air under the ceiling in heating mode and more horizontally in air conditioning mode;

  3. respected a lateral setback from the angle to avoid turbulence and noise.

The proximity of a low shelf led us to orient the air blade in such a way as to bring the temperature towards the occupied area, while protecting the documents and stored objects.

Refrigeration and drain path: short, clean, durable

The drilling was carried out on the right side of the unit , in line with the outlets provided by the manufacturer. We have:

  • sleeved the passage with a sheath to protect the insulation;

  • installed a coordinated external capping to shelter the insulated copper lines and the power cable ;

  • installed a gravity drain with a controlled slope , equipped with a non-return valve to avoid any odors in summer.

This ultra-compact path limits heat losses, reduces heating start-up time and facilitates maintenance .

Power supply and secure commissioning

Our certified technicians have verified:

  • the presence of a circuit dedicated to the electrical panel according to the intensity required by the head and the associated condenser;

  • earth continuity and circuit breaker conformity;

  • the crimping and sealing of refrigeration connections by nitrogen testing and deep vacuum drawing in accordance with the rules of the art in HVAC installation .

Commissioning concluded with calibration of the probes , verification of the air flow , then a hot/cold functional test over several cycles to ensure stability.

Result: immediate comfort and fine air management

Right out of the box:

  • the heating mode reaches the setpoint quickly, with almost no stratification ;

  • the air conditioning mode maintains a comfortable humidity , very appreciable during heat waves in Montreal;

  • automatic ventilation adapts the speed as needed, almost inaudible in steady state.

The room became a quiet workspace during the day and a restful bedroom at night, without unpleasant drafts.

HVAC Maintenance: What to Plan to Maintain Efficiency

A high-performance HVAC system deserves regular maintenance . We recommend:

  • cleaning the filters every 4 to 8 weeks (more frequent in the presence of animals or dust);

  • annual inspection by AirGreen: control of exchangers , verification of drain , measurement of pressures and temperatures , gentle cleaning of the outdoor unit;

  • Be careful of obstacles in front of the facade (boxes, baskets, textiles) which disrupt the air intake.

These simple actions maintain performance , extend lifespan and reduce consumption .

Grants and Eligibility

Depending on the configuration chosen (power, efficiency, and pairing with the condenser), the Fujitsu wall-mounted heat pump may be eligible for certain assistance programs for Quebec residences. We support our customers in:

  • eligibility verification ;

  • preparation of supporting documents ;

  • optimizing the choice of equipment to meet the required performance criteria.

Best practices that we systematically apply

  • Minimum connection lengths to limit fluid losses and loads.

  • Logical path : exit on axis, curvature radius respected, continuous insulation.

  • Condensate management : controlled slope, anti-siphon, accessible drain points.

  • Acoustics : silent blocks on the condenser, anti-vibration positioning, self-optimized speed.

  • Aesthetics : Clean chutes on the outside, clean seal at the exit point.

Pitfalls to avoid (feedback from Montreal, Laval, Longueuil)

  1. Saturation of the recovery by high furniture: the unit must breathe.

  2. Drilling too low or too high : a poor drain slope causes summer seepage.

  3. Unprotected or overly taut wiring : fragility during seasonal expansion.

  4. Oversizing the BTU power: short cycles, discomfort, overconsumption.

  5. Lack of maintenance : reduced heat exchange, compressor overload, noise.

Deadlines and typical progress of our projects

For a piece like this, the intervention generally follows this outline:

  • Technical visit and validation of clearances (30 to 45 min).

  • Interior installation : support, drilling, hanging the head, connections (2 to 3 hours).

  • Exterior installation : supports, capping, connections, tests (2 to 3 hours).

  • Commissioning : vacuum extraction, checks, demonstration of use (45 to 60 min).

Our turnkey service covers Montreal, Laval , Longueuil , North Shore and South Shore , with planned slots to minimize the impact on your daily life.

Why AirGreen?

  • A team specializing in Fujitsu and recent multi-brand wall-mounted heat pumps .

  • Measurable quality of execution : straight lines, clean capping, documented tests.

  • Support that doesn't stop at installation: maintenance, usage optimization, filter reminders.

In a district as lively as Villeray–Saint-Michel–Parc-Extension , every square meter counts. Our method guarantees discreet integration and lasting comfort , summer and winter.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).