Job sheet · Project

Installation of a Goodman wall-mounted heat pump in Le Sud-Ouest

AirGreen installs a Goodman wall-mounted heat pump in Le Sud-Ouest: discreet integration, gravity drain, four-season comfort. HVAC installation and maintenance services in Montreal, Laval, Longueuil, North Shore, and South Shore.

By AirGreen Climatisation & Chauffage Admin7 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
7 minto read the whole story
–type of installation
2025year published
At a glance

The job on one screen

The full story

The article, chapter by chapter

A clean and energy-efficient integration into a Greater Montreal condo

At AirGreen , we have just installed a Goodman wall-mounted heat pump in an apartment in the Le Sud-Ouest sector of Montreal. The owner wanted stable four-season comfort, a discreet unit and a neat HVAC installation that respects the interior aesthetics. This project illustrates our way of working: precise audit, choice of equipment adapted to the actual volume, clean execution and meticulous commissioning, with complete support on HVAC maintenance and subsidies .

Client background and objectives

The main space is a living room open to a kitchen, with low ceilings, matte green painted walls, and track lighting. The needs: efficient cooling during heat spikes, supplemental heating in the mid-season, and lower energy bills compared to electric baseboard heaters. The wall-mounted Goodman meets these criteria thanks to its inverter modulation, low power consumption, and quiet operation—an asset for a condo.

Why Goodman here?

Goodman offers a reliable and affordable wall-mounted range, with 9,000 to 12,000 BTU units commonly used for rooms of 350 to 550 sq ft depending on the envelope and sunlight. We choose this family when looking for:

  • excellent value for money for a residential space;

  • installation flexibility (well-designed fixing template, easy service access);

  • high efficiencies and fine modulation at partial load to maintain a stable temperature without over-ventilation.

Quick reading of the environment and sizing

Before any recommendation, we measure:

  • Surface area and volumes (open area, ceiling height);

  • Sunshine (southwest-facing bay windows);

  • Sealing (recent doors/windows, weatherstripping, air infiltration);

  • Uses (daytime occupation, cooking appliances, audiovisual equipment).

The load calculation leads to a range between 9,000 and 12,000 BTU . We favor reasonable sizing: too large = short cycles, less dehumidification; too small = inconsistent comfort. Here, the Goodman wall head, installed high under the ceiling , ensures uniform diffusion along the load-bearing wall, without blowing directly onto the occupants.


Our installation method: cleanliness, safety and durability

Installation of the indoor unit

  • Height and clearances. We position the headboard a few centimeters from the ceiling to promote warm air intake and clear airflow. Directional louvers adjust to prevent drafts in the seating area.

  • Fixing. Installation on a mounting plate with anchors adapted to the support. Laser level control for a gravity drain without stagnation.

  • Finishing. The unit arrives with protective films that we remove at the end of testing. The covers are fitted to eliminate any light and reduce unwanted noise.

Refrigeration, electricity and drain path

Even though the photo mainly shows the head, our standard includes:

  • Single drilling behind the unit (∅ 65 mm typ.), with waterproof sheath and continuous insulation on the copper pair;

  • Discreet white capping as required on the inside; on the outside, UV sheath and stainless steel fixings;

  • Gravity condensate drain with controlled slope; when the layout requires it, we offer a silent condensate pump (splash tray, alarm contact);

  • Dedicated power supply for the outdoor compressor (double-pole circuit breaker, disconnect box), and shielded communication cable between units, neatly laid. We respect clearances and circuit separation for compliance.

Commissioning and quality controls

  • Deep vacuum < 500 microns, resistance test, then opening of the valves;

  • Current checks , superheat/subcooling depending on conditions, defrost test;

  • Remote control calibration (modes, setpoint, auto speed, dehumidification);

  • Usage tips : realistic instructions, Auto vs Heat/Cool mode, filter maintenance.

Visible details and best practices

On the Goodman head, we notice:

  • a wide horizontal flap that directs the flow without whistling noise;

  • multi-position vertical vanes to sweep the room;

  • a flush hood that neatly hides the wall crossing.

These choices are not cosmetic: well-adjusted diffusion allows the setpoint to be reached with lower ventilation , therefore more silence and savings.


Result for the customer

  • Immediate cooling comfort , with effective dehumidification on hot days;

  • Appreciable additional heating in spring and autumn, reducing the use of baseboards;

  • Lower consumption thanks to the inverter which modulates according to the actual load;

  • Preserved aesthetics : discreet integration, no unnecessary visible sheathing, careful finishing.

HVAC Maintenance: Simple and Crucial

To maintain performance:

  • Cleaning filters every 4 to 8 weeks during the season;

  • Annual inspection by AirGreen: heat exchange, condensates, electrical tightening, parameter updates;

  • Cleaning the evaporator and fan if dust accumulates (preserves efficiency and silence).

We offer maintenance plans tailored to condos and houses in Montreal , Laval , Longueuil , North Shore and South Shore .

Grants and Eligibility

High-performance wall-mounted heat pumps are generally eligible for assistance programs in Quebec. We assist our clients in verifying the eligibility of the indoor unit and outdoor compressor combination and preparing the application (detailed invoices, serial numbers, installation photos). Our team monitors evolving criteria to optimize your investment.


What we recommend before buying

1) Size, don't guess. A load calculation avoids unpleasant surprises.
2) Think about the route. Gravity drain is preferable; a reliable pump remains a good option if the route requires it.
3) Take care of the exterior. Support the condenser outside the ice fall zone, adequate height in winter, snow guards if necessary.
4) Plan for maintenance. Filtration and service access must be simple.
5) Check the power supply. Dedicated line to the compressor, compliant protections and correctly shielded communication cable.

What we see too often… and what we correct

  • Drillings without slope causing droplets on the wall;

  • Interrupted insulation on the suction line (condensation and cold spots);

  • Loose drain that vibrates and generates noise;

  • Cables not separated from 240 V (risk of interference on communication).

Our construction sites are systematically checked at the end of the work to avoid these pitfalls.


AirGreen in Greater Montreal

We install and maintain heat pumps and wall-mounted air conditioners throughout Greater Montreal : the Southwest, Plateau, Ville-Marie , as well as Laval , Longueuil , the North Shore and the South Shore . Our team combines engineering, HVAC installation and customer service to deliver high-performance systems that last.

Want controlled comfort at home?

Whether you're renovating a condo or upgrading a single-family home, we offer solutions from Goodman , Fujitsu, Gree, Midea, LG, Sharp , and other well-known brands. We recommend equipment based on your building , not the other way around. A technical visit helps determine the right capacity, the best layout, and the most cost-effective option in light of available subsidies .


Technical sheet - key points of this installation

  • Type : wall-mounted heat pump (reversible wall-mounted air conditioner )

  • Brand : Goodman

  • Typical capacity for this type of space: 9,000–12,000 BTU

  • Installation : top of wall, gravity drain with slope; rear drilling; white capping finish if required

  • Elec.: Dedicated circuit for the outdoor unit; shielded communication cable

  • Commissioning : vacuum, functional tests, customer instructions, maintenance advice

Result: stable comfort , silence , optimized consumption , respected aesthetics.


Next step

Contact AirGreen for a free evaluation . We cover Montreal, Laval, Longueuil, North Shore, South Shore and coordinate logistics, HVAC installation , maintenance and financial assistance optimization for you.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment