Project

Installation of a Goodman wall-mounted heat pump in Sainte-Rose (Laval)

In Sainte-Rose (Laval) , AirGreen installs a Goodman wall-mounted heat pump on brackets , with a cover and external cut-off . A clean, durable and efficient HVAC installation for four-season comfort in Greater Montreal .

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Goodman wall-mounted heat pump in Sainte-Rose (Laval)
Installation of a Goodman wall-mounted heat pump in Sainte-Rose (Laval)
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

A neat upgrade on the front: wall bracket, straight cowling and exterior cut-off for reliable four-season performance

In Sainte-Rose (Laval) , a family hired us to modernize the comfort of a single-family home clad in vinyl siding . The need was clear: efficient supplemental heating in winter, quiet air conditioning in summer, and a clean integration on a facade visible from the driveway. We recommended a Goodman wall-mounted heat pump —a mini-split well-suited to North Shore residences—and we organized an HVAC installation that prioritized aesthetics, durability, and ease of maintenance.


Installation: why wall mounting is essential here

We install the outdoor unit on galvanized brackets mechanically fixed in the base masonry. This choice:

  • Elevates the unit to protect it from splashes, mud and accumulated snow;

  • Reduces the risk of premature corrosion ;

  • Facilitates the flow of condensates and defrost cycles;

  • Limits the transmission of vibrations to the floor and interior parts.

Each bracket is fitted with anti-vibration pads and the tightening torque is checked to avoid any resonance with the facing. The horizontality is checked at the level, which determines the proper lubrication of the compressor and the stability of the fan.


Connection path: clean and watertight vertical cover

The insulated refrigeration tubes and the communication cable are grouped behind a white vertical cover (capping) , placed straight between the vinyl slats. Advantages:

  • Mechanical protection against impacts and sunlight;

  • Sealing the drilling (fire-resistant foam and peripheral sealing);

  • Simplified maintenance : clip-on covers allow quick access to flare fittings and insulators.

Inside and out, we maintain a sufficient radius of curvature to avoid points of pressure loss and refrigerant noise .


Power supply: service box and protected conduit

To the right of the unit, we install an exterior disconnect box , compliant with the electrical code, to quickly isolate the device during work. The power supply runs through a protected conduit and then enters the building through a sealed opening. This configuration:

  • Secures operation in all weathers;

  • Facilitates troubleshooting and seasonal checks;

  • Maintains a clear reading of the electrical path, without messy visible cables.


Condensate and defrost management

In heating mode, the heat pump periodically enters defrost mode. On wall mount, we leave clearance under the unit for natural drainage and we avoid any direct obstruction under the tray. The precise leveling promotes drainage and prevents ice stalactites that could harm the fixings.


Sizing and expected results

The sizing takes into account losses (insulation, infiltration, orientation) and internal gains (occupancy, appliances). On this house:

  • The capacity of the mini-split comfortably covers the main living area;

  • Inverter modulation limits on/off cycles, reduces noise and stabilizes temperature;

  • In summer, dehumidification improves the feeling of comfort at moderate settings;

  • In the off-season and in mild winters, the heat pump significantly reduces the bill compared to baseboards or a simple convector.


Finishing touches: paying attention to visible details

The vinyl siding facade requires proper installation:

  • Suitable stainless steel or galvanized screws ;

  • Spacers to align the brackets despite the covering blade of the covering;

  • Treatment of the piercing : reconstituted vapor barrier, insulation around the connections, waterproofing touch-up .

The result is visually discreet : centered device, straight cowling, aligned service box, with no floating cables or exposed insulation.


Recommended HVAC maintenance (cyclical and preventive)

To maintain performance:

  • Periodic cleaning of the external exchanger (without bending the fins);

  • Checking the fasteners , buffers and hood ;

  • Control of currents and temperatures under load;

  • Inspection of the drain and winter drainage path ;

  • Updated the labeling on the service box.

Annual HVAC maintenance minimizes efficiency losses and extends equipment life.


Grants and Eligibility

High-performance wall-mounted heat pumps are often eligible for Quebec assistance programs when seasonal efficiency criteria are met and installation is carried out by a licensed contractor . Our team:

  • Check eligibility based on home configuration;

  • Provides the necessary documents (detailed invoice, serial numbers, technical sheets);

  • Guides you through to filing the application.


Common mistakes avoided on this facade

  • Too low installation exposed to snow accumulations: here, the ground clearance is sufficient for Laval winters.

  • Undersized brackets : We chose a model with an admissible load greater than the weight of the unit, with margin for shear.

  • Unsealed drilling behind capping: we seal before capping.

  • Air recirculation due to a lateral obstacle: the unit is clear and centered between the downspout and the basement window.

  • Forgetting the external cut-off : the service box is installed and identified.


Useful tips for owners in Laval, Montreal, Longueuil, North Shore and South Shore

  • Clear the appliance before winter (leaves, objects, decorations).

  • Leave 30 to 45 cm free around the sides and back for suction.

  • Avoid spraying the unit directly with a high-pressure jet.

  • If the coating is being renovated, plan the removal and reinstallation with us to preserve the integrity of the connections.

  • Consider seismic mounting of the fixings if the facade receives impacts (ball, bicycle).


Why AirGreen for your HVAC installation in Laval and Greater Montreal?

Our approach combines thermal diagnostics , controlled field execution and after-sales service . We deliver a clear installation file : anchor photos, routing diagram, equipment references and maintenance reminders. By working on hundreds of homes in Laval, Montreal, Longueuil, North Shore and South Shore , we know how to adapt the installation to the realities of vinyl facades, masonry and Quebec winters.


Quick project sheet (Sainte-Rose)

  • System : Goodman wall-mounted heat pump (residential mini-split).

  • Support : galvanized wall brackets with anti-vibration pads.

  • Path : white vertical cover ; sealed drilling; intact insulation.

  • Electrical : outdoor disconnect box ; protected conduit.

  • Comfort targeted : summer air conditioning, winter auxiliary heating, controlled consumption.

Naturally integrated keywords : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore .

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment