Installation of a Gree FreeMatch R32 MultiZone heat pump in Chomedey (Laval)
HVAC installation of a Gree FreeMatch R32 MultiZone heat pump in Chomedey (Laval) : zoned comfort, cold performance and discreet enclosure. AirGreen, heat pump expert for Montreal, Laval, North Shore and South Shore .

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A complete and scalable HVAC modernization for a Laval home
At AirGreen , we have just completed the HVAC installation of a Gree FreeMatch R32 MultiZone heat pump in a residential area of Chomedey (Laval) . The home, a light brick house with a backyard and wooden balcony, required a solution that combines efficient heating and cooling , precise room-by-room air conditioning , and controlled consumption . The FreeMatch R32 platform was the obvious choice: it allows several indoor heads to be powered with a single compact outdoor condenser , for customized comfort and a reduced visual footprint.
Project context and client objectives
The owner wanted:
-
Standardize comfort upstairs and downstairs.
-
Reduce reliance on electric baseboard heaters.
-
Preserve the aesthetics of the facade and the floor space.
-
Choose a scalable solution, capable of accepting an additional head later.
Our recommendation: a Gree FreeMatch R32 MultiZone heat pump (2 to 4 zones), sized to cover the main living areas, with a reserve capacity for a future room.
Outdoor installation: performance and discretion
The outdoor unit is fixed on galvanized wall brackets , at a height calculated for:
-
clear snow drifts in winter and facilitate flow;
-
promote air circulation around the exchanger;
-
protect the device from shocks and ground moisture.
The refrigerant lines run laterally along the masonry, then penetrate the partition near the rear staircase to reach the interior heads by the shortest route. We installed a light-colored rigid finishing cover to protect the insulation , hide the pipes and harmonize the whole with the white brick. Anti-vibration silent blocks complete the fixing to reduce sound transmission.
MultiZone Architecture: comfort by zones
The FreeMatch R32 platform allows you to connect 2 to 5 heads (wall, floor consoles, cassettes). For this project:
-
Zone 1 – Living Room/Kitchen : Wide-spread wall head for minimal stratification and stable sweeping.
-
Zone 2 – Bedrooms : wall-mounted head with finely modulated flow for a silent night .
-
Zone 3 – Basement : floor console (optional depending on the final configuration) ensuring excellent sweeping at the bottom of the room .
Each zone uses its own remote control and an inverter algorithm that finely adjusts the compressor frequency. The result: uniform temperature , smooth starts , and optimized consumption .
R-32 Technology: Efficiency and Regulatory Future
The R-32 refrigerant in the recent Gree range offers:
-
best seasonal efficiency (SEER/HSPF) at equivalent power;
-
reduced charge compared to R-410A;
-
lower global warming potential , in line with future regulatory guidelines.
For the climate of Greater Montreal, the chosen configuration maintains efficient heating down to the low temperatures frequently encountered, with controlled defrosting and attractive capacity maintenance during prolonged cold spells.
Installation details: AirGreen rigor throughout
Drilling and sealing
-
Targeted drilling from the outside to preserve the brick and avoid joints.
-
Frost- resistant expanding foams and sheaths to secure the envelope.
-
Sealing and flashing at entry points for continuity of the air barrier.
Pipe routing
-
Balanced lengths between heads to stabilize refrigerant distribution.
-
Bending radii respected to avoid any stress on the copper tubes.
-
Gravity slope ensured for condensate; where gravity was not possible, a silent mini condensate pump with integrated alarm was provided.
Electrical and protections
-
Dedicated circuit pulled to main panel with CSA compliant breaker .
-
Accessible outdoor disconnect switch , near the condenser, according to code.
-
Grounding and UV jackets for durability.
Finishes
-
UV-stable cover , stainless steel screws, anti-UV collars , and butyl tape at the junctions.
-
Leak tests under nitrogen, deep vacuum , and commissioning with pressure/temperature readings.
Sizing and expected performance
The BTU selection is based on the surface area and the thermal balance of the zones. For this type of Laval house, the usual configuration is between 24,000 and 36,000 total BTUs distributed between 3 heads, with:
-
High SEER for summer air conditioning ;
-
Competitive HSPF for mid-season and mid-winter heating ;
-
fine modulation to avoid overheating and short cycles.
In practice, the first surveys indicate:
-
rapid temperature rise in the basement;
-
stability of the living room despite the late afternoon solar input;
-
very low noise levels , both indoors and in the backyard.
Results for the client
-
Zoned comfort : each occupant sets their room to the desired temperature .
-
Savings : Inverter modulation reduces electrical demand compared to baseboards.
-
Aesthetics : a single condenser for the entire house and a discreet cover .
-
Scalability : possibility of adding a head in a future layout.
Recommended HVAC maintenance
To maintain performance and air quality :
-
Clean indoor unit filters every 4 to 8 weeks depending on usage.
-
Clear the outdoor battery of leaves and dust in spring and fall.
-
Schedule annual HVAC maintenance : electrical inspection, tightening, condensate testing, pressure/temperature readings, defrost and inverter control check.
-
In winter, maintain clearance around the condenser to prevent snow accumulation.
Grants and Eligibility
Recent R-32 and ENERGY STAR® heat pumps may be eligible for various programs in Quebec. We assist each application to maximize assistance when the chosen configuration and performance criteria allow. Residents of Montreal, Laval, Longueuil, the North Shore, and the South Shore can entrust us with verifying the criteria and preparing the required documents.
Pitfalls to Avoid in a MultiZone Project
-
Undersizing a head for an open area: risk of over-stressing and increased noise.
-
Non-compliant line lengths : capacity losses and imbalance between zones.
-
Positioning the condenser too low : exposure to snow and runoff.
-
Omitting condensate management for remote heads: risks of alarm and shutdown in summer.
Why AirGreen for your MultiZone Gree
We work daily in Greater Montreal and are familiar with local architectural features : masonry, narrow walkways, balconies, and backyard access. Our approach combines:
-
Thermal study by zones;
-
Route plan for pipes and cables;
-
Clean and secure HVAC installation ;
-
Instrumented commissioning ;
-
Support for maintenance and longevity.
This Gree FreeMatch R32 installation in Chomedey demonstrates the balance we seek in every project: measurable comfort , visual discretion and lasting performance , with the flexibility needed to evolve the house.
AirGreen – Air Conditioning & Heating
Your HVAC partner for Montreal, Laval, Longueuil, the North Shore and the South Shore . Technical advice, certified installation and annual maintenance for heat pumps , MultiZone heat pumps and wall-mounted air conditioners .
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).