Installation of a Gree (Livo R32 range) wall-mounted heat pump in LaSalle
Gree Livo R32 installation in LaSalle by AirGreen: R-32 wall-mounted heat pump, high installation, short run, gravity evacuation and quiet comfort. HVAC expertise for Montreal, Laval, Longueuil, North Shore and South Shore.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Gree Livo R32 9 000 (115 V) | 10,000 | 7,600 | −25 °C: 5,700 | 1.86 | 20.5 | 8.8 | – |
| Gree Livo R32 9 000 | 9,600 | 7,600 | −25 °C: 5,500 | 1.94 | 20.5 | 8.8 | – |
| Gree Livo R32 12 000 (115 V) | 9,700 | 8,500 | −25 °C: 6,500 | 1.75 | 19.0 | 8.5 | – |
| Gree Livo R32 12 000 | 9,700 | 9,100 | −25 °C: 6,500 | 1.8 | 19.0 | 8.5 | $1,164 |
| Gree Livo R32 18 000 | 15,300 | 12,100 | −25 °C: 10,200 | 1.85 | 20.0 | 8.5 | $1,836 |
| Gree Livo R32 24 000 | 19,200 | 15,700 | −25 °C: 10,500 | 1.75 | 19.0 | 8.5 | $2,304 |
| Gree Livo R32 30 000 | 24,000 | 23,000 | −25 °C: 16,900 | 1.8 | 22.0 | 9.0 | $2,880 |
| Gree Livo R32 36 000 | 27,400 | 24,600 | −25 °C: 21,000 | 1.8 | 21.0 | 8.5 | $3,288 |
According to NEEP, it delivers 10,000 BTU/h at −8 °C (17 °F), as much as at 8 °C. It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,700 BTU/h, 63% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,300 BTU/h, 48% more than its nominal 9,000 BTU size.
According to NEEP, its COP at −15 °C is 1.94: the highest of the Livo R32 line, which ranges from 1.75 to 1.86 at that temperature.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,500 BTU/h, 61% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,136 BTU/h, 46% more than its nominal 9,000 BTU size.
According to NEEP, it delivers 8,500 BTU/h at −15 °C, against 9,100 for the Gree Livo R32 12 000.
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 8,500 BTU/h, 71% of its nominal 12,000 BTU size. Its COP there is 1.75.
According to NEEP, it delivers 9,100 BTU/h at −15 °C, against 8,500 for the Gree Livo R32 12 000 (115 V).
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 9,100 BTU/h, 76% of its nominal 12,000 BTU size. Its COP there is 1.80.
At 8 °C, its certified maximum capacity reaches 22,500 BTU/h, 25% more than its nominal 18,000 BTU size.
According to NEEP, its certified minimum capacity is at least 7,000 BTU/h at every temperature. In a small, well-insulated room it will cycle on and off more often: size it carefully.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 12,100 BTU/h, 67% of its nominal 18,000 BTU size. Its COP there is 1.85.
At −25 °C, its certified minimum capacity is 3,100 BTU/h (5,800 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 15,700 BTU/h, 65% of its nominal 24,000 BTU size. Its COP there is 1.75.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 23,000 BTU/h, 77% of its nominal 30,000 BTU size. Its COP there is 1.80.
According to NEEP, its COP at −25 °C is 1.54: the highest of the Livo R32 line, which ranges from 1.30 to 1.52 at that temperature.
At −25 °C, its certified minimum capacity is 7,000 BTU/h (10,000 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 24,600 BTU/h, 68% of its nominal 36,000 BTU size. Its COP there is 1.80.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.A dash in the aid column: amount to be confirmed for this model.
The article, chapter by chapter
An energy-efficient upgrade tailored for a bright condo in southwest Montreal
At AirGreen , we have just installed a Gree wall-mounted heat pump — Livo R32 series —in a condo in the LaSalle district of Montreal. The goal: to provide stable, quiet, and economical comfort for a partially open-plan space, while preserving the interior aesthetics . The result: discreet integration, precise blowing, and tangible energy savings 12 months a year.
The context: a compact space that requires precision and discretion
The living area features white walls and a side window near the chosen location. We chose to install the unit high up on a load-bearing wall to optimize:
-
air stratification (capture of calories in air conditioning mode and improvement of mixing in heating mode);
-
the blowing range towards the main room;
-
visual discretion , the unit aligning naturally above the furniture.
This configuration avoids air recirculation near the ceiling and promotes uniform comfort without direct air currents in the living area.
Why the Gree Livo R32 range?
Gree's Livo R32 range stands out for its high seasonal efficiency , ultra-quiet operation , and discreet display integrated into the front panel—readable from a distance without obstructing the field of vision. Its advantages for a condo in LaSalle:
-
R-32 refrigerant , with lower GWP than R-410A and better suited to current requirements;
-
Inverter compressor finely modulating power, reducing on/off cycles and consumption;
-
Comfort in extreme cold adapted to the Montreal climate, with capacity maintained down to low temperatures*;
-
Quiet mode and multi-directional flaps for comfortable and targeted blowing;
-
Improved filtration for healthier air in urban environments.
*Exact ranges depending on the selected BTU capacity and configuration: we always size the power based on the actual characteristics of the accommodation (exposure, insulation, volumes, glazing).
Sizing and layout: the detail that makes the difference
We size BTU power based on three pillars : winter heat loss, summer solar gain, and occupancy patterns. For this apartment, the 9,000 to 12,000 BTU range is typically adequate; thermal analysis, ceiling height, and glazing orientation guided the final choice in the Livo R32 range .
Interior layout:
-
Intentionally high height to free up useful space and increase the blowing range.
-
Clearances respected around the unit to optimize the sweeping of the shutters and facilitate maintenance.
-
Discreet LED display on the right front: convenient for checking setpoint and operating status at a glance.
Outdoor installation (condenser):
-
Wall brackets with silent blocks to limit vibration transmission to the frame and clear the device of snow in winter.
-
Orientation favoring free air evacuation and safe maintenance access.
-
Short, continuously insulated refrigeration passage to limit losses and maximize SEER/SCOP in actual use.
The technical route: short, clear, efficient
The location—near a wall facing outside —allows for a very short cooling path (approximately 30 to 40 cm from the back of the indoor unit to the outlet). Concrete advantages:
-
Less pressure loss , therefore better performance;
-
Less visual footprint : white capping matching the wall makes the path almost invisible;
-
Gravity evacuation of condensates , without additional pump, therefore increased simplicity and reliability .
We systematically tighten the brazing torques and carry out a deep vacuum (≤ 500 microns) before commissioning to guarantee the absence of humidity and air, essential conditions for the durability of the compressor and stable performance .
Electrical Safety and Compliance
-
Dedicated circuit sized according to nameplate and cable length;
-
Appropriate circuit breaker and external service switch in accordance with standards;
-
Grounding verified and communication conductors clearly marked .
This rigor prevents parasitic triggering and ensures stable communication between the indoor head and the outdoor unit, the key to a high-performance inverter .
Commissioning: Numbers, not guesses
Commissioning includes:
-
Nitrogen leak test ;
-
Vacuum drawing and stabilization;
-
Measurements of blowing/suction temperatures, ΔT in air conditioning, absorbed intensity ;
-
Verification of simulated defrosting and sensors;
-
Timing of the flaps to minimize the effect of “short cycling” of air in the area near the ceiling.
The ΔT observed in cold mode and the stability of the setpoint confirm adequate sizing for the main room, with a comfort margin for the inter-seasons.
Result for the customer: consistent comfort and controlled bill
-
Rapid cooling of main volumes;
-
Efficient supplementary heating during cold peaks, reducing dependence on more energy-intensive systems;
-
Very low noise level : ideal for teleworking and resting;
-
Smoothed consumption thanks to inverter modulation.
HVAC Maintenance: The Winning Schedule
To maintain performance:
-
Clean filters every 4–8 weeks (more frequently during pollen or construction periods).
-
Visual check of the capping, clearance of the outdoor unit and condensate drainage at each change of season.
-
Annual maintenance by AirGreen: deep cleaning of the evaporator, checking of connections, testing of probes, inspection of supports and defrosting.
Regular maintenance protects the compressor and maintains the advertised performance .
Grants and Eligibility
The Gree Livo range of high-efficiency R-32 wall-mounted heat pumps are generally eligible for Quebec programs (depending on the configuration chosen and the criteria in force), particularly in Greater Montreal: Montreal, Laval, Longueuil, North Shore and South Shore . We support our customers in:
-
eligibility verification (performance range, approvals);
-
preparation of documents (detailed invoices, photos, serial numbers);
-
submission to the relevant programs.
Pitfalls to avoid (AirGreen feedback)
-
Undersize to “save money”: the compressor will run harder, noise and wear increase.
-
Too long refrigeration journey : pressure losses, reduced efficiency, increased bill.
-
Non-gravity condensate drainage when possible: pump unnecessarily stressed and maintenance more cumbersome.
-
Insufficient clearances around the condenser: less efficient defrosting, penalized winter performance.
Why AirGreen for your HVAC installation in LaSalle and throughout Greater Montreal?
-
Certified in-house team , specialized in wall-mounted heat pumps from Gree, Fujitsu, Midea, Sharp, etc.
-
Proven methodology : audit, sizing, implementation, instrumented commissioning, photo file and technical report .
-
Responsive after-sales service and scheduled HVAC maintenance to ensure your investment lasts.
For a condo, a multiplex or a single-family home, we offer tailor-made solutions, always aligned with Montreal's climate reality and the strictest industry standards .
Technical sheet - in brief
-
Type : wall-mounted heat pump (mini-split)
-
Brand : Gree
-
Range : Livo R32 (BTU selection adapted to the space)
-
Interior layout : load-bearing wall, high installation, optimized clearances
-
Refrigeration path : very short , discreet white capping
-
Condensates : gravity drainage
-
Condenser : on brackets with silent blocks, clear of the ground for snow
-
Customer objective : quiet comfort, controlled consumption, preserved aesthetics
Conclusion
This Gree installation (Livo R32 range) in LaSalle illustrates our way of working: detailed analysis , clean execution and measured performance . The condo gains in comfort in summer and winter, without compromising on the elegance of the space. For projects in Montreal, Laval, Longueuil, North Shore and South Shore , our AirGreen team delivers sustainable , scalable installations ready for the coming years of energy-efficient heating and air conditioning .
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).