Project

Installation of a Gree (R-32 range) wall-mounted heat pump in Rosemont–La Petite-Patrie

AirGreen installs a Gree R-32 wall-mounted heat pump in an attic room in Rosemont–La Petite-Patrie : short connections, gravity evacuation, condenser on brackets, quiet and efficient comfort for Montreal, Laval , Longueuil , North Shore , South Shore .

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Gree (R-32 range) wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Gree (R-32 range) wall-mounted heat pump in Rosemont–La Petite-Patrie
–chapters in this story
6 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

Optimized four-season comfort in an attic bedroom in Greater Montreal

In this typical brick residence in Rosemont–La Petite-Patrie , our AirGreen team modernized the comfort of an upstairs bedroom by installing a Gree wall-mounted heat pump (recent R-32 range) . The objective: to ensure precise cooling in the summer and efficient heating in the winter, even in the intense cold of Greater Montreal (Montreal, Laval , Longueuil , North Shore , South Shore ), while reducing consumption compared to the existing electric baseboard heater.

Context and challenges of the place

  • Attic room with sloping roof and central sliding window .

  • Old electric baseboard kept as an extra.

  • External wall immediately behind the internal head: ideal for gravity outlet of condensate and short crossing of connections .

  • Tight urban environment (brick plex facing the window), calling for a discreet and anti-vibration exterior installation.


Why a Gree R-32 wall-mounted heat pump for this project?

Next-generation efficiency and refrigerant

The Gree R-32 series offer very good seasonal efficiencies and reliable operation in cold weather (down to approximately −25°C depending on the series), with a low GWP refrigerant compared to the R-410A generations. This is in line with the energy efficiency and footprint reduction expectations sought in Montreal and its surrounding areas.

Precise comfort in attic spaces

Attic rooms accumulate heat in the summer and lose it in the winter. A well-positioned wall-mounted radiator manages:

  • Stratification thanks to the adjustable motor shutter and fine fan speeds.

  • Airflow directed along the entire length of the room without direct airflow onto the bed.

  • Low noise level , essential for a bedroom.

Eligibility for programs

The high-efficiency wall-mounted heat pumps in this R-32 range are generally integrated into the subsidy programs in effect in Quebec (depending on models and criteria). We support our customers from the eligibility diagnosis to the preparation of parts for Montreal, Laval, Longueuil, North Shore and South Shore .


Our HVAC installation process on this site

1) Technical visit and preparation

  • Survey of clearances near the attic ceiling.

  • Checking the electrical location of the condenser and the required circuit breaker size .

  • Choosing a wall-to-wall passage behind the head to minimize the length of the connections (≈ 2 to 3 m in total).

2) Positioning of the inner head

  • Installation on mounting plate with laser level.

  • Upper clearance respected for air intake and maintenance.

  • Height optimized so that the air jet sweeps the room without directly hitting the occupant.

3) Drilling and evacuation of condensates

  • Drilling inclined outwards for gravity evacuation (no visible pump or additional noise).

  • High density ducts and insulation to prevent condensation on the interior finish.

4) Refrigeration connections and power supply

  • Flares calibrated with torque meter and tightening torques in accordance with the manufacturer.

  • Nitrogen test (pressure test) then deep vacuum to protect the compressor and maximize longevity.

  • Power supply to the condenser with external disconnect ; the head is powered via the outdoor unit, as recommended by most wall-mounted units.

5) Installation of the external condenser

  • Installation on anti-vibration wall brackets , clear of the ground for snow (≈ 16–18 in).

  • Orientation of air discharges so as not to disturb the neighborhood or reintegrate towards the window.

  • Care taken in the routing of the connections and the cleanliness of the capping for a clean result on brick.

6) Commissioning and calibration

  • Check for overheating/subcooling , check for leaks , configure Auto/Heat/Cool modes , test defrost .

  • Usage tips: managing night-time instructions , cleaning filters , programming .


Result: comfort, silence and savings

  • Even cooling on hot days, even under roofs.

  • Reliable heating at low temperatures, greatly reducing the use of electric baseboard heaters .

  • Very low noise both indoors and outdoors, significant in dense residential areas.

  • Aesthetics : head centered above the window, compact connections, discreet exterior.


AirGreen best practices and advice

Choice of power (BTU)

  • Attic room: be careful of solar gains and losses through the roof . A simple load study avoids over/under-sizing.

  • The Gree R-32 ranges are available in 9k, 12k, 18k, 24k BTU : you select according to need , not intuition.

Head implantation

  • Avoid heavy curtains in the immediate vicinity.

  • Maintain sufficient clearance above and around the head for free air intake .

  • Angle the shutter to sweep the room rather than blow on the occupant.

Condensate and winter management

  • Priority gravity (simple, silent, durable).

  • Outdoors, maintain snow clearance and check defrosting during prolonged cold weather.

HVAC Maintenance

  • Filters : rinse quarterly (more frequent if dust/pollen).

  • Cleaning of coils and inspection of connections : annual.

  • AirGreen Maintenance Plan : Extends lifespan and maintains efficiency.


Grants and administrative support

In Greater Montreal (Montreal, Laval, Longueuil, North Shore, South Shore), efficient R-32 wall-mounted heat pumps are often part of assistance programs . For each file, we confirm the model match , the compliant installation and the required documents (quotes, proof, technical photos if requested). Our team manages the certification and advises on the order of steps to speed up payment.


Why AirGreen for your project in Montreal and surrounding areas?

  • Local expertise in residential HVAC installation in plexes and houses in Greater Montreal .

  • Quality procedures : nitrogen, deep vacuum, controlled torques, clean wiring, levels checked.

  • After-sales service : performance monitoring and planned HVAC maintenance .

  • Grant support : simplification from A to Z.


Summary technical sheet (Rosemont project)

  • Type : wall-mounted heat pump .

  • Brand : Gree , recent R-32 range (exact model not displayed by customer).

  • Interior layout : head above the window , ceiling clearance respected.

  • Route : wall-to-wall , short connections (≈ 2–3 m), gravity condensate .

  • Exterior : condenser on raised brackets , anti-vibration , controlled discharge orientation.

  • Energy : maintain baseboard heating as a backup; prioritize heat pump for efficiency.


A similar project in Montreal, Laval, Longueuil, North Shore or South Shore ?

At AirGreen , we size, install, and maintain R-32 wall-mounted heat pumps tailored to local needs (brick plexes, attics, single-family homes). Tell us about your space : we'll provide a clear, costed scenario, ready for financial assistance.


Keywords worked on : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore , Gree R-32 , Rosemont–La Petite-Patrie .

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment