Installation of a Gree (R-32 range) wall-mounted heat pump in Rosemont–La Petite-Patrie
AirGreen installs a Gree R-32 wall-mounted heat pump in an attic room in Rosemont–La Petite-Patrie : short connections, gravity evacuation, condenser on brackets, quiet and efficient comfort for Montreal, Laval , Longueuil , North Shore , South Shore .

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Optimized four-season comfort in an attic bedroom in Greater Montreal
In this typical brick residence in Rosemont–La Petite-Patrie , our AirGreen team modernized the comfort of an upstairs bedroom by installing a Gree wall-mounted heat pump (recent R-32 range) . The objective: to ensure precise cooling in the summer and efficient heating in the winter, even in the intense cold of Greater Montreal (Montreal, Laval , Longueuil , North Shore , South Shore ), while reducing consumption compared to the existing electric baseboard heater.
Context and challenges of the place
-
Attic room with sloping roof and central sliding window .
-
Old electric baseboard kept as an extra.
-
External wall immediately behind the internal head: ideal for gravity outlet of condensate and short crossing of connections .
-
Tight urban environment (brick plex facing the window), calling for a discreet and anti-vibration exterior installation.
Why a Gree R-32 wall-mounted heat pump for this project?
Next-generation efficiency and refrigerant
The Gree R-32 series offer very good seasonal efficiencies and reliable operation in cold weather (down to approximately −25°C depending on the series), with a low GWP refrigerant compared to the R-410A generations. This is in line with the energy efficiency and footprint reduction expectations sought in Montreal and its surrounding areas.
Precise comfort in attic spaces
Attic rooms accumulate heat in the summer and lose it in the winter. A well-positioned wall-mounted radiator manages:
-
Stratification thanks to the adjustable motor shutter and fine fan speeds.
-
Airflow directed along the entire length of the room without direct airflow onto the bed.
-
Low noise level , essential for a bedroom.
Eligibility for programs
The high-efficiency wall-mounted heat pumps in this R-32 range are generally integrated into the subsidy programs in effect in Quebec (depending on models and criteria). We support our customers from the eligibility diagnosis to the preparation of parts for Montreal, Laval, Longueuil, North Shore and South Shore .
Our HVAC installation process on this site
1) Technical visit and preparation
-
Survey of clearances near the attic ceiling.
-
Checking the electrical location of the condenser and the required circuit breaker size .
-
Choosing a wall-to-wall passage behind the head to minimize the length of the connections (≈ 2 to 3 m in total).
2) Positioning of the inner head
-
Installation on mounting plate with laser level.
-
Upper clearance respected for air intake and maintenance.
-
Height optimized so that the air jet sweeps the room without directly hitting the occupant.
3) Drilling and evacuation of condensates
-
Drilling inclined outwards for gravity evacuation (no visible pump or additional noise).
-
High density ducts and insulation to prevent condensation on the interior finish.
4) Refrigeration connections and power supply
-
Flares calibrated with torque meter and tightening torques in accordance with the manufacturer.
-
Nitrogen test (pressure test) then deep vacuum to protect the compressor and maximize longevity.
-
Power supply to the condenser with external disconnect ; the head is powered via the outdoor unit, as recommended by most wall-mounted units.
5) Installation of the external condenser
-
Installation on anti-vibration wall brackets , clear of the ground for snow (≈ 16–18 in).
-
Orientation of air discharges so as not to disturb the neighborhood or reintegrate towards the window.
-
Care taken in the routing of the connections and the cleanliness of the capping for a clean result on brick.
6) Commissioning and calibration
-
Check for overheating/subcooling , check for leaks , configure Auto/Heat/Cool modes , test defrost .
-
Usage tips: managing night-time instructions , cleaning filters , programming .
Result: comfort, silence and savings
-
Even cooling on hot days, even under roofs.
-
Reliable heating at low temperatures, greatly reducing the use of electric baseboard heaters .
-
Very low noise both indoors and outdoors, significant in dense residential areas.
-
Aesthetics : head centered above the window, compact connections, discreet exterior.
AirGreen best practices and advice
Choice of power (BTU)
-
Attic room: be careful of solar gains and losses through the roof . A simple load study avoids over/under-sizing.
-
The Gree R-32 ranges are available in 9k, 12k, 18k, 24k BTU : you select according to need , not intuition.
Head implantation
-
Avoid heavy curtains in the immediate vicinity.
-
Maintain sufficient clearance above and around the head for free air intake .
-
Angle the shutter to sweep the room rather than blow on the occupant.
Condensate and winter management
-
Priority gravity (simple, silent, durable).
-
Outdoors, maintain snow clearance and check defrosting during prolonged cold weather.
HVAC Maintenance
-
Filters : rinse quarterly (more frequent if dust/pollen).
-
Cleaning of coils and inspection of connections : annual.
-
AirGreen Maintenance Plan : Extends lifespan and maintains efficiency.
Grants and administrative support
In Greater Montreal (Montreal, Laval, Longueuil, North Shore, South Shore), efficient R-32 wall-mounted heat pumps are often part of assistance programs . For each file, we confirm the model match , the compliant installation and the required documents (quotes, proof, technical photos if requested). Our team manages the certification and advises on the order of steps to speed up payment.
Why AirGreen for your project in Montreal and surrounding areas?
-
Local expertise in residential HVAC installation in plexes and houses in Greater Montreal .
-
Quality procedures : nitrogen, deep vacuum, controlled torques, clean wiring, levels checked.
-
After-sales service : performance monitoring and planned HVAC maintenance .
-
Grant support : simplification from A to Z.
Summary technical sheet (Rosemont project)
-
Type : wall-mounted heat pump .
-
Brand : Gree , recent R-32 range (exact model not displayed by customer).
-
Interior layout : head above the window , ceiling clearance respected.
-
Route : wall-to-wall , short connections (≈ 2–3 m), gravity condensate .
-
Exterior : condenser on raised brackets , anti-vibration , controlled discharge orientation.
-
Energy : maintain baseboard heating as a backup; prioritize heat pump for efficiency.
A similar project in Montreal, Laval, Longueuil, North Shore or South Shore ?
At AirGreen , we size, install, and maintain R-32 wall-mounted heat pumps tailored to local needs (brick plexes, attics, single-family homes). Tell us about your space : we'll provide a clear, costed scenario, ready for financial assistance.
Keywords worked on : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore , Gree R-32 , Rosemont–La Petite-Patrie .
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).