Installation of a GREE Livo R32 wall-mounted heat pump in Chomedey (Laval)
AirGreen installs a GREE Livo R32 wall-mounted heat pump under a balcony in Chomedey: raised support, protected connections, optimized drainage. Four-season comfort and efficiency for Greater Montreal.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A thoughtful installation under the balcony for stable performance all year round
At AirGreen , we are responsible for the HVAC installation of a GREE Livo R32 wall-mounted heat pump in a house in the Chomedey sector of Laval . The objective: to offer four-season comfort with a protected outdoor installation under a balcony , without compromising on airflow , durability and ease of maintenance . The chosen configuration combines a short connection passage, careful management of the condensation drain and an elevation on a metal support to preserve performance in both winter and summer.
Project context and client expectations
The owner wanted:
-
reliable additional heating in very cold weather, to reduce your electricity bill;
-
precise and quiet air conditioning in living areas;
-
a discreet installation, with no visual impact on the courtyard;
-
a recent R-32 system, compatible with the grant programs applicable in Greater Montreal (Montreal, Laval , Longueuil, North Shore , South Shore ).
We recommended the GREE Livo R32 , a wall-mounted heat pump known for its high seasonal efficiency , its inverter compressor and its operating stability in cold climates.
Choice of location: sheltered, ventilated, accessible
The outdoor condenser is installed under a wooden balcony , sheltered from direct precipitation and summer solar radiation. To comply with the rules of the art:
-
We have ensured sufficient clearance above and in front of the fan for air circulation and defrost cycles.
-
The unit rests on a raised galvanized steel base , fixed on concrete slabs and a clean stone bed for perfect drainage and better stability .
-
Anti-vibration pads limit sound transmission to the balcony structure.
-
The connection capping (light gray color) protects the insulated refrigeration pipes , the power cable and the drain , while making the assembly discreet and easily accessible for HVAC maintenance .
This installation optimizes the longevity of the compressor, prevents snow accumulation around the unit and facilitates service .
Link path and condensate management
We choose a short, straight route between the interior head and the condenser to reduce pressure losses and maximize efficiency . The condensation drain is led into the same chute and then directed to a suitable evacuation point, promoting gravity flow and avoiding any risk of dripping onto the facade . The jointing at the drilling is carried out with sealing foam and vapor barrier to preserve the watertightness of the envelope.
Why the GREE Livo R32?
The Livo R32 range is part of GREE's new R-32 platforms. It features:
-
a variable speed compressor that finely modulates power;
-
high seasonal efficiency in cooling (SEER) and heating (HSPF), conducive to energy savings ;
-
a heating operating range adapted to the climate of the North Shore ;
-
a contained noise level , both on the interior side and on the condenser side;
-
washable filters and easy access to components for maintenance .
Depending on the area served, the range offers capacities from 9,000 to 24,000 BTU , which allows the device to be precisely adjusted to the actual needs of the home.
Key steps in our installation
-
Thermal assessment of the main parts and identification of the shortest holes.
-
Laying the raised support : checking the level, mechanical sealing, compacted stone bed for stability and drainage.
-
Connections : dehydrated refrigeration copper, controlled bends , high density insulation, nitrogen leak tests .
-
Deep vacuum with calibrated pump, vacuum resistance control and opening of service valves.
-
Dedicated electrical connections , in accordance with the Code, with suitable circuit breaker and external disconnect switch .
-
Start-up and calibration : verification of temperature deltas in cold/heat modes, ventilation speed , and customer training in eco modes .
Finish and aesthetics: maximum discretion
The gray capping blends into the vinyl siding of the foundation. The curvature radii at the condenser outlet are generous to maintain connections and avoid wear points. The condenser's installation height , combined with the balcony's shelter, protects the unit from:
-
blown snow ;
-
ice on the ground;
-
runoff water during thaws.
Results obtained
Upon commissioning, the customer notes:
-
temperature stability in the open area;
-
very low perceived noise under the balcony and inside;
-
rapid response to load variations thanks to the inverter ;
-
a reduction in on/off cycles , a guarantee of durability .
Best practices and pitfalls to avoid (AirGreen feedback)
-
Always maintain the required clearances around the condenser, even under a balcony: free space on the facade and above is essential for air flow and defrosting .
-
Raise the unit above the anticipated snow level and provide a drainage plan (clean stone + slabs) to avoid puddles and corrosion .
-
Limit the length and bends of the connections: the shorter the route, the better the efficiency .
-
Protect the condensation drain from freezing and ensure a continuous slope .
-
Avoid overly closed recesses : insufficient air volume leads to increases in static pressure and a drop in efficiency.
-
Plan maintenance : a poorly accessible location complicates periodic checks (coils, connections, pressures).
Recommended HVAC maintenance
To maintain the performance of the wall-mounted heat pump :
-
Cleaning the inner head filters every 4 to 8 weeks during periods of heavy use;
-
Annual inspection by our technicians: pressures, temperatures, connections, condition of the capping , electrical tightening;
-
Clearances around the condenser: remove leaves, dust and any obstruction to the air flow ;
-
Check the drain when the snow melts and at the beginning of summer.
Regular maintenance extends the life of the device and maintains performance coefficients .
Grants and Eligibility
Recent R-32 systems like the GREE Livo R32 meet the criteria of current energy efficiency programs when the required seasonal performance is achieved. Depending on the chosen capacity and performance indices , the project may be eligible for incentives applicable in Greater Montreal - one more reason to modernize your equipment in Laval , Montreal , Longueuil , on the North Shore and the South Shore . Our team supports the preparation of files and the validation of technical criteria.
Why entrust your project to AirGreen?
-
Local HVAC expertise : hundreds of installations optimized for the climatic realities of the greater region.
-
Quality of execution : careful brazing, leak tests , controlled vacuum , fine calibration at the end of the project.
-
Respect for aesthetics : compact routes, harmonized trunking , integration under balcony where relevant.
-
Structured after-sales service : maintenance reminders, prioritization during peak periods, parts availability.
Conclusion: a sustainable and intelligent installation in Chomedey
This GREE Livo R32 wall-mounted heat pump installation in Chomedey illustrates our approach: choosing the most protective and efficient location, careful finishing and guaranteeing measurable performance in all seasons. Thanks to the balcony shelter, the raised support , controlled drainage and the quality of the installation , the owner benefits from stable comfort , optimized consumption and a system ready to face the Laval winters.
AirGreen supports households in Montreal , Laval , Longueuil , North Shore and South Shore in their heat pump , wall-mounted air conditioner and HVAC maintenance projects. Our team travels, evaluates, installs and monitors each system so that it delivers its full potential year after year.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Gree Livo R32 9 000 (115 V) | 10,000 | 7,600 | −25 °C: 5,700 | 1.86 | 20.5 | 8.8 | – |
| Gree Livo R32 9 000 | 9,600 | 7,600 | −25 °C: 5,500 | 1.94 | 20.5 | 8.8 | – |
| Gree Livo R32 12 000 (115 V) | 9,700 | 8,500 | −25 °C: 6,500 | 1.75 | 19.0 | 8.5 | – |
| Gree Livo R32 12 000 | 9,700 | 9,100 | −25 °C: 6,500 | 1.8 | 19.0 | 8.5 | $1,164 |
| Gree Livo R32 18 000 | 15,300 | 12,100 | −25 °C: 10,200 | 1.85 | 20.0 | 8.5 | $1,836 |
| Gree Livo R32 24 000 | 19,200 | 15,700 | −25 °C: 10,500 | 1.75 | 19.0 | 8.5 | $2,304 |
| Gree Livo R32 30 000 | 24,000 | 23,000 | −25 °C: 16,900 | 1.8 | 22.0 | 9.0 | $2,880 |
| Gree Livo R32 36 000 | 27,400 | 24,600 | −25 °C: 21,000 | 1.8 | 21.0 | 8.5 | $3,288 |
According to NEEP, it delivers 10,000 BTU/h at −8 °C (17 °F), as much as at 8 °C. It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,700 BTU/h, 63% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,300 BTU/h, 48% more than its nominal 9,000 BTU size.
According to NEEP, its COP at −15 °C is 1.94: the highest of the Livo R32 line, which ranges from 1.75 to 1.86 at that temperature.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,500 BTU/h, 61% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,136 BTU/h, 46% more than its nominal 9,000 BTU size.
According to NEEP, it delivers 8,500 BTU/h at −15 °C, against 9,100 for the Gree Livo R32 12 000.
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 8,500 BTU/h, 71% of its nominal 12,000 BTU size. Its COP there is 1.75.
According to NEEP, it delivers 9,100 BTU/h at −15 °C, against 8,500 for the Gree Livo R32 12 000 (115 V).
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 9,100 BTU/h, 76% of its nominal 12,000 BTU size. Its COP there is 1.80.
At 8 °C, its certified maximum capacity reaches 22,500 BTU/h, 25% more than its nominal 18,000 BTU size.
According to NEEP, its certified minimum capacity is at least 7,000 BTU/h at every temperature. In a small, well-insulated room it will cycle on and off more often: size it carefully.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 12,100 BTU/h, 67% of its nominal 18,000 BTU size. Its COP there is 1.85.
At −25 °C, its certified minimum capacity is 3,100 BTU/h (5,800 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 15,700 BTU/h, 65% of its nominal 24,000 BTU size. Its COP there is 1.75.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 23,000 BTU/h, 77% of its nominal 30,000 BTU size. Its COP there is 1.80.
According to NEEP, its COP at −25 °C is 1.54: the highest of the Livo R32 line, which ranges from 1.30 to 1.52 at that temperature.
At −25 °C, its certified minimum capacity is 7,000 BTU/h (10,000 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 24,600 BTU/h, 68% of its nominal 36,000 BTU size. Its COP there is 1.80.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.A dash in the aid column: amount to be confirmed for this model.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).