Project

Installation of a Gree residential series wall-mounted heat pump in Ahuntsic-Cartierville

Gree wall-mounted heat pump installed high on a wall in Ahuntsic-Cartierville. AirGreen optimizes nighttime comfort, energy efficiency, and HVAC finishing for apartments and houses in Greater Montreal.

By AirGreen Climatisation & Chauffage Admin7 min read
Installation of a Gree residential series wall-mounted heat pump in Ahuntsic-Cartierville
Installation of a Gree residential series wall-mounted heat pump in Ahuntsic-Cartierville
–chapters in this story
7 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

A high-mounted headboard for precise comfort and impeccable aesthetics in a Montreal bedroom

At AirGreen , we design HVAC systems that respect the architecture of Montreal homes while maximizing energy efficiency. In this project in Ahuntsic-Cartierville , we installed a Gree wall-mounted heat pump in a bright bedroom. The interior head is installed flush with the ceiling, on the window side , to optimize hot air intake in summer, improve stratification in winter, and keep the walls clear for furnishings.

Housing context and performance objectives

The owner wishes to:

  • Replace an energy-consuming portable air conditioner with a four-season solution that can heat efficiently at low temperatures.

  • Preserve the aesthetics of the room (light walls, exposed curtain rod) and limit visible work.

  • Reduce your year-round electricity bill without compromising nighttime operating silence .

After evaluating the heat load, the 9,000 to 12,000 BTU range is preferred for this room and the adjoining area, with the possibility of later expansion to a MultiZone configuration if the client wishes to cover other rooms.

Why a Gree mural for Ahuntsic-Cartierville?

The Gree wall-mounted heat pump is a must-have here for several reasons:

  • DC inverter : fine power modulation, better seasonal factor and reduced cycling.

  • Low temperature heating : maintains capacity during the typical Montreal cold, ensuring winter comfort.

  • Low noise level : ideal for a bedroom, even at medium or low speed.

  • Reliable electronics and common parts available in Greater Montreal, simplifying maintenance.

The installed model belongs to Gree's residential series (compact indoor unit with discreet display on the front), perfectly suited to bedrooms and offices.

Positioning of the inner head: precision to the millimeter

The choice of the high area, near the ceiling , is not insignificant:

  • It promotes a homogeneous air mixture : the blown air runs along the ceiling, travels through the room and descends naturally, avoiding cold areas.

  • It frees up the passage area around the window and preserves the rod and curtains.

  • It limits visual clutter: the head remains discreet, aligned with the cornice, with minimal interior capping and the same color as the wall.

The horizontal louvers are set to push air toward the back of the room, while the vertical louvers distribute the flow without blowing directly onto the bed. This setting prevents drafts felt at night and maximizes the comfort temperature .

Refrigeration path and condensate evacuation

The piercing is made on the back of the head with a slight outward slope to:

  • Maintain a reliable (without pump) and quiet gravity drain .

  • Reduce the total length of continuously insulated copper refrigeration connections, a guarantee of efficiency and durability.

  • Allow for a clean, waterproof, UV-treated exterior cover for resistance to sunlight.

We ensure continuous insulation throughout to prevent condensation during humid weather. The collars, tapes, and foams used are HVAC- specified and rated for Quebec temperatures.

Outdoor unit: clearances, noise and winter maintenance

The Gree outdoor unit is installed on the courtyard side, on anti-vibration wall brackets with calibrated silent blocks. This choice:

  • Provides sufficient ground clearance for snow and defrost water.

  • Keeps vibrations away from the lightweight structure of the balcony.

  • Facilitates maintenance (fin washing, seasonal inspection).

The recommended clearances around the intake and exhaust panels are respected in order to preserve the air flow and avoid the recycling of hot air in heating mode. The orientation limits the noise impact on neighbors; the nominal noise level remains low thanks to the inverter and fine adjustments during commissioning.

Key steps in AirGreen installation

  1. Technical survey : load measurement, connection routes, identification of the electrical panel and drilling areas.

  2. Tracing and plate : reinforced fixing in the structure, leveling control and anticipation of the drain slope.

  3. Clean core drilling with a sleeve, waterproof sealant and adequate weatherstripping to reduce air infiltration.

  4. Connections : brazed/welded annealed copper, high-density insulation, anti-UV tape, shielded communication cable according to the Gree series.

  5. External mounting : galvanized brackets, dowels suitable for the support, grounding.

  6. Deep vacuum : vacuum pump and digital gauges, extended leak test; charge added if length exceeds factory charge.

  7. Powering up and setting up : checking intensities, supply/return temperatures , adjusting shutters and speeds for night-time comfort.

  8. Delivery to the customer : instructions for use and maintenance, annual HVAC maintenance schedule.

Challenges encountered and solutions implemented

  • Proximity to the window : so that the curtain does not disrupt the airflow, the head is moved forward a few millimeters and the shutters are set to blow above the rod.

  • Smooth painted siding : to avoid marks around the capping, we use a flush capping and a discreet fixing which allows for clean disassembly during future painting work.

  • Night silence : “Quiet/Night” mode is programmed with a progressive temperature setting to avoid perceptible restarts.

Results measured after commissioning

  • Delta T in cooling greater than 10°C between return and blowing at medium speed, attesting to the good performance of the exchanger.

  • Stable comfort at bedtime and at the end of the night, without air currents directed towards the sleeping area.

  • Controlled consumption thanks to prolonged operation at low speed and maintaining realistic setpoints (23–24°C in summer / 21°C in winter).

Recommended HVAC maintenance

To maintain performance and longevity:

  • Clean the Gree head filters every 4 to 8 weeks during use.

  • Keep the outdoor unit clear (leaves, snow, objects) and monitor drainage during freeze/thaw periods.

  • Schedule annual maintenance : electrical inspection, leak test, cleaning of exchangers, checking of superheat/subcooling parameters.

  • After a storm or micro-outage, turn off/restore the power at the circuit breaker and restart after a few minutes if necessary.

Grants and Eligibility

Efficient wall-mounted heat pumps may be eligible for certain financial assistance when the criteria (low temperature performance, Energy Star certification, high SEER/HSPF) are met. Our team supports customers in Ahuntsic-Cartierville , Laval , Longueuil , North Shore and South Shore to validate eligibility, prepare photos/serial numbers and submit applications on time.

AirGreen Tips for a Perfectly Tempered Room

  • Right capacity : Oversizing increases cycling and decreases comfort; we size according to the room envelope and orientation.

  • Smart guidelines : aim for 21°C in winter and 23–24°C in summer at night; avoid too tight a gap that puts unnecessary strain on the inverter.

  • Shutter management : orient slightly towards the ceiling to extend the range and avoid direct blast .

  • Air quality : take advantage of the dehumidification mode during humid periods, and open the windows occasionally for additional ventilation.

Why entrust your installation to AirGreen?

We understand the constraints of Montreal housing : varied load-bearing walls, sometimes restricted access, demanding co-ownerships, and harsh climates. Our commitment:

  • On-site studies , clear and quantified recommendations.

  • Rigorous execution in accordance with Quebec electrical and refrigeration standards.

  • Structured after-sales service and HVAC maintenance to guarantee the durability of your heat pump .

Are you in Montreal , Laval , Longueuil , on the North Shore or the South Shore ? Our teams bring the same technical standards and the same integration finesse to clean, efficient installations, ready for Quebec winters.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).