Job sheet · Project

Installation of a Gree wall-mounted heat pump in Sainte-Julie

AirGreen installed a Gree wall-mounted heat pump in Sainte-Julie. A powerful and discreet HVAC solution, ideal for homes on the South Shore, Montreal, Laval, Longueuil, and the North Shore.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

The full story

The article, chapter by chapter

Four-season comfort for a South Shore home

At AirGreen , we recently installed a Gree wall-mounted heat pump in a residence located in Sainte-Julie , on the South Shore of Montreal. The owner was looking for an efficient and discreet solution to cool his home in the summer and heat it during the winter, while taking advantage of the grant programs available for this type of device.

The Gree wall-mounted heat pump proved to be a wise choice: a perfect balance between performance, sleek design and energy efficiency, all with an installation that integrates perfectly into the interior of the home.


Technical characteristics of the installed unit

The device chosen by the customer is a Gree wall-mounted heat pump , known for its reliable technology and durability.

  • Capacity : 12,000 BTU, ideal for the main room of the house.

  • Inverter Technology : Allows for precise adjustments, reducing temperature variations and improving efficiency.

  • Seasonal efficiency : SEER greater than 20, providing substantial savings on electricity bills.

  • Efficient heating mode : designed to operate down to -25°C, essential for Quebec winters.

  • Quiet operation : the wall head blends into the room without compromising acoustic comfort.

This equipment is generally eligible for provincial and federal grant programs (notably Hydro-Québec and the federal energy-efficient renovation program).


The particularities of the installation

The installation presented some challenges related to the layout of the house:

  • Indoor positioning : the unit was fixed on a central wall, close to a window, ensuring even diffusion of air in the space.

  • Discreet capping : the refrigeration ducts have been clad in dark gray capping to blend in with the wall and window frame.

  • Condensate management : gravity drainage was preferred, simplifying future maintenance and minimizing the risk of breakdown.

  • Outdoor installation : the condenser was strategically placed on a concrete slab, away from traffic areas, to limit noise and ensure easy access for periodic maintenance.

This approach ensures aesthetic integration and long-term reliability .


Immediate comfort after installation

Upon commissioning, the owner noted:

  • A rapid reduction in indoor temperature on a hot day.

  • Stable and constant comfort in heating mode, without unpleasant variations.

  • A reduction in noise level , even during intensive operation.

The wall-mounted remote control provides precise and intuitive control, while the discreet LED display on the unit continuously confirms the set temperature.


The advantages of a Gree heat pump for a South Shore home

Choosing a Gree wall-mounted heat pump means benefiting from:

  • Significant energy savings thanks to high seasonal performance.

  • A modern and minimalist design , which harmonizes with different interior decoration styles.

  • Four-season comfort , both in air conditioning and heating.

  • A solid warranty , generally 10 years on parts and the compressor.

For residents of Sainte-Julie and the South Shore, this technology represents a smart choice, both for comfort and for the resale value of the home.


AirGreen expertise: a turnkey service

Our team ensures to deliver a complete and professional service to each installation:

  • Assessment of the actual thermal needs of the house.

  • Selecting the device best suited to the spaces.

  • Installation carried out in accordance with current HVAC standards.

  • Complete performance testing before delivery to the customer.

  • Detailed explanations for simple and effective maintenance (cleaning filters, frequency of professional maintenance, checking ducts).

Thanks to this rigor, we guarantee immediate comfort and optimal durability for each project.


Conclusion

With this Gree wall-mounted heat pump installation in Sainte-Julie , the owner now benefits from a high-performance, energy-efficient and discreet system, adapted to the climatic realities of Quebec.

At AirGreen , we offer more than just an installation service: we support our clients to transform each project into a sustainable and comfortable solution, whether in Montreal, Laval, Longueuil, on the North Shore or the South Shore.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment