Installation d’une Gree Vireo R32 thermopompe murale à Rosemont–La Petite-Patrie
Reading time: 7'

Installation of a Gree Vireo R32 wall-mounted heat pump in Rosemont–La Petite-Patrie

Four-season comfort in a Rosemont condo: a clean, fast HVAC installation designed for the Montreal climate

The customer context

In a bright condo in Rosemont–La Petite-Patrie , our client was looking for a quiet, efficient, and reliableheating and cooling solution to replace an old window fan and reduce reliance on electric baseboard heaters. The priorities: stable comfort in the open living room-kitchen area, measurable energy savings, and impeccable aesthetics inside and out.

The technical choice: Gree Vireo R32 12,000 BTU

Here we recommend a Gree Vireo R32 12,000 BTU, perfectly sized for an open area of ​​35–50 m² typical of Montreal condos. This R-32 range meets current requirements for efficiency and environmental impact, while offering:

  • seasonal efficiency up to ≈ 20 SEER2 in cooling;

  • an HSPF2 around 9–10 for heating;

  • a useful heating capacity down to -25°C , ideal for our winters;

  • a low noise level, very popular in condos .

Desired result: immediate comfort in summer and in the off-season, lower electricity bills in winter, and almost imperceptible operation.


Our AirGreen method: precision, cleanliness, performance

Visit and load calculations

  • Quick thermal assessment (orientation, glass surfaces, sealing, occupants, cooking appliances).

  • Validation of refrigerant connection lengths and gravity drainage to avoid the addition of a condensate pump.

  • Checking the dedicated electrical circuit and the location of the external circuit breaker.

Inner head positioning

  • The wall head is installed at the correct height for optimal scanning of the open area.

  • Clearances respected for maintenance and air circulation; the diffusion covers the kitchen and living room without direct air currents on the seating area.

  • Single hole (≈ 65 mm) behind the unit for invisible connections inside and a clean exit to the outside.

Refrigeration path and condensate evacuation

  • Insulated copper refrigeration lines installed with particular care on the bending radii, brazing under nitrogen and nitrogen leak testing .

  • Gravity drainage with continuous outward slope, which eliminates the risk of pump noise and simplifies HVAC maintenance .

  • Exterior capping matching the facade, UV-resistant, for a durable and discreet finish.

Outdoor unit and anti-vibration

  • Condenser fixed on sturdy wall brackets (galvanized steel), anti-vibration wedges to protect the masonry and reduce noise transmission.

  • Clearances provided for winter defrosting and air circulation.

  • Accessible external circuit breaker ; wiring to current standards.

  • Minimum level above the snow to avoid accumulation and ensure good water drainage during defrosting.

Commissioning and quality controls

  1. Deep vacuum (≤ 500 microns) with extended draw, purge and stabilization.

  2. Opening of pre-charged R-32 fluid, superheat/subcooling control .

  3. Complete test in cold and heat, measurement of intensity and delta T.

  4. Setting auto scan , eco mode and timers.

  5. HVAC user guide and maintenance tips provided to the customer.


Why this Gree Vireo R32 is a good match for Rosemont

  • Local climate : the ability to heat down to –25°C covers the majority of cold temperatures encountered on the Island of Montreal and the North Shore .

  • Efficiency : R-32 and high efficiencies reduce operating costs, especially compared to baseboards.

  • Silence : low sound pressure is suitable for adjoining buildings and condominiums.

  • Aesthetics : simple interior unit; discreet exterior capping , in accordance with the requirements of co-ownership associations.

Salient installation details (construction site side)

  • Total length of links optimized (≈ 5–7 m in this case) to preserve efficiency.

  • Direct wall-to-wall crossing , without excessive bends, to limit pressure losses.

  • 100% gravity-based condensate management with continuous slope, avoiding additional maintenance.

  • Careful finishing of the holes (sleeve, sealant, vapor barrier) for a lasting seal.


Instructions for use and maintenance (to maintain performance)

  • Filter : vacuum monthly during periods of heavy use; quickly wash with warm water then dry thoroughly.

  • Exchanger : Plan for professional cleaning of the coils every 18–24 months (suitable R-32 detergent).

  • Outdoor unit : Clear leaves, snow and ice; check that nothing is obstructing the rear.

  • Modes : favor Auto mode in summer and Heat stable in winter; avoid frequent hot/cold switching.

  • Temperature : Aim for a constant setting (22–23°C) to maximize COP and comfort.


Grants and incentives

High-efficiency R-32 wall-mounted heat pumps are generally eligible for certain assistance programs in Quebec. Depending on the period and your municipality ( Montreal, Laval, Longueuil, North Shore, South Shore ), Hydro-Québec or municipal incentives may apply. We always verify eligibility and prepare, if necessary, the documents for your file.


What the customer actually gains

  • 4-season comfort : uniform cooling in summer and gentle warmth in winter.

  • Savings : significant reduction in consumption linked to baseboards.

  • Quiet : Minimal noise, perfect for teleworking and movie nights.

  • Value : Improved appeal of the condo on the rental and resale market.

  • Peace of mind : clean installation, manufacturer's warranty and local AirGreen service .


Key steps of a typical project with AirGreen

  1. Technical evaluation and detailed offer (dimensions, BTU, yields, installation scenarios).

  2. Planning with your availability and that of the condominium association if necessary.

  3. One-day installation for a standard wall-mounted air conditioner/heat pump head.

  4. Instrumented commissioning and user training.

  5. Follow-up : maintenance reminder, filters, service availability in 24–72 hours depending on the season.


Best practices to remember (and pitfalls to avoid)

  • Sizing : Aim for the correct BTU output; oversizing reduces efficiency in mid-season.

  • Drain : always use gravity ; a pump is a last resort.

  • External support : provide the height suitable for snow/frost episodes.

  • Electricity : Dedicated circuit compliant; avoid extension cords or shared outlets.

  • HVAC Maintenance : A clean filter is worth kilowatts saved and a longer lifespan.


Why AirGreen

As a field HVAC installer, we combine practical engineering , attention to detail and local after-sales service . With every project, our promise is simple: an efficient , aesthetic and durable solution, ready for Montreal winters as well as heat waves.


Are you in Montreal , Laval , Longueuil , on the North Shore or the South Shore ?

Our team covers the entire Greater Montreal area. Whether you're looking for a wall-mounted heat pump , a multi-zone system , a central heat pump , or HVAC maintenance , we size and install with the same high standards.


Project summary sheet

  • Type : wall-mounted heat pump (heating + air conditioning function)

  • Brand / Range : Gree Vireo R32

  • Capacity : 12,000 BTU (open concept condo)

  • Installation : single drilling, gravity drain , discreet exterior capping, anti-vibration wall brackets

  • Advantages : high efficiency, useful heating at –25°C , very low noise

  • HVAC maintenance : monthly filter, professional check every 18–24 months


Ready for uncompromising comfort?

Contact us for a quick quote. At AirGreen , we take care of the selection , HVAC installation , and monitoring . Your comfort is guaranteed, season after season.


Useful keywords : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore , Gree Vireo R32 , Rosemont–La Petite-Patrie .

Leave a comment