Project

Installation of a Gree Vireo R32 wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension

HVAC installation of a Gree Vireo R32 wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension: back-to-back installation, short lines, gravity condensate and measured commissioning (~10–12 °C in blowing). Interventions Montreal, Laval, Longueuil, North Shore, South Shore.

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Gree Vireo R32 wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Installation of a Gree Vireo R32 wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Immediate comfort, precise adjustments and R-32 efficiency in a Montreal plex
In a typical Villeray–Saint-Michel–Parc-Extension apartment, we are installing a Gree Vireo R32 wall-mounted heat pump to provide rapid cooling in the summer and stable supplemental heating in the mid-season. Our goal: a clean, quiet, and easy-to-maintain HVAC system , perfectly suited to the constraints of plexes and condominiums in Greater Montreal .

Client context and objectives

The owner was looking for:

  • Responsive comfort for the main living area (living room + open dining room).

  • An efficient R-32 solution, compatible with energy efficiency trends.

  • A discreet installation that does not alter the interior architecture or the facade.

  • Simplified maintenance and very low noise level.

We recommend the Gree Vireo R32 for its balance of performance, silence and control options (fine modes, timer, Wi-Fi depending on configuration). The operating range is suitable for hot summers and cool mid-seasons in Montreal , Laval and Longueuil .

Installation details – controlled back-to-back and careful finishing

  • Configuration : Back-to-back installation. The interior head is fixed close to the ceiling to optimize air stratification; direct passage at the rear to the outside.

  • Drilling : 65 mm core with slight slope for drainage; waterproof filling with vapor barrier and air barrier compatible mastic.

  • Refrigeration lines : short length (≈ 3 to 5 m) limiting pressure losses; brazing under nitrogen , high-density continuous insulation, anti-abrasion collars.

  • Condensate drainage : gravity , insulated pipe to prevent condensation on cold walls; discreet outlet with non-return spout.

  • Electricity : dedicated power supply, calibrated circuit breaker; external disconnect switch near the condenser.

  • Outdoor unit : fixed on galvanized wall brackets with silent blocks ; clearances respected for effective defrosting in winter; anchoring compliant with the support.

Performance checks at commissioning

After deep vacuuming and leak testing, we validate the pressure stability and compressor intensity. In air conditioning mode, the blown air temperature measured at the outlet drops to around 10–12°C , a sign of efficient heat exchange and a well-configured flow rate. The fan is then adjusted to balance silence and range.

Why the Gree Vireo R32 in this project?

  • R-32 refrigerant : reduced charge, better EER/SEER at equivalent configuration.

  • Quiet : compressor and inverter fan; night mode for sensitive periods.

  • Comfort control : fine shutter adjustments, timer, automatic restart after failure.

  • Performance : adapted to the requirements of several efficiency programs (eligibility to be validated on a case-by-case basis).

  • Simple HVAC maintenance **: accessible filters, easy cleaning of the exchanger.

Aesthetic and acoustic integration

We take care of the exterior capping (UV channel) matching the rear facade. Inside, the head is centered for even diffusion and to avoid dead zones . The silent blocks and the anchor length reduce structural vibrations – essential in plexes with wooden floors.

Key steps of our AirGreen methodology

  1. Technical survey : room dimensions, wall structure, location of electrical panel, condensate drainage.

  2. BTU sizing : calculation based on volumes, solar gains and use; proposal 9k/12k/18k BTU depending on the thermal load.

  3. Installation plan : shortest route, drilling in safe area (excluding uprights/spacers), position of brackets.

  4. Preparation : furniture protection, tarpaulins and HEPA vacuum cleaner for a clean construction site.

  5. Installation : supports, soldering, line insulation, connections.

  6. Commissioning : vacuum < 300 microns, stabilization, top-up if required, functional test.

  7. Discount : mode guide (Auto, Dry, Heat, Fan), good HVAC maintenance practices , energy saving instructions.

Concrete results for the client

  • Immediate comfort thanks to the cold blown air measured around 10–12°C at the outlet, even on hot days.

  • Quiet noise level : the Vireo R32 operates without parasitic hum thanks to mechanical decoupling.

  • Aesthetics preserved : compact capping and discreet condensate outlet.

  • Controlled operating costs : inverter modulation which adapts power to actual needs.

Good usage practices

  • Maintain clearances around the head and do not obstruct the grilles.

  • In summer, choose a set point of 23–24°C and Dry mode on very humid days.

  • In the off-season, use Heat mode for a quick top-up without restarting the main system.

  • Program the timer and Eco mode when away.

  • Clean the filters every 4 to 6 weeks during periods of use; plan annual HVAC maintenance (cleaning the exchanger, checking load, intensities, condensates).

Technical points to watch out for in Montreal plexes

  • Drillings : respect the air barrier/vapor barrier and ensure a durable seal to prevent infiltration and mold.

  • Condensates in humid climates : minimum slope and outlet protected against frost; in the case of a complex route, provide a mini-pump with a steam barrier.

  • Noise pollution : choose a rear facade or a side yard, set the night mode; inform the condominium if necessary.

  • Winter : Clear the outdoor unit of snow and ice; check defrosting during mild weather.

Alternatives proposed by AirGreen according to needs

  • Gree Livo R32 for excellent value for money.

  • Gree Sapphire R32 when extreme silence and cold performance are priorities.

  • Interior systems (1-way cassette, ducted , console ) when required by the architecture.

  • MultiZone R-32 heat pump if multiple rooms need to be air conditioned/heated independently.

Grant and compliance support

We assist our clients in verifying eligibility for available energy efficiency programs (performance criteria, location Montreal , Laval , Longueuil , North Shore , South Shore ) and we provide the necessary technical documents. Electrical standards and mechanical clearances are respected for a safe and durable installation.

Why choose AirGreen for your HVAC installation?

Our teams understand the realities of Montreal buildings : composite walls, restricted access, noise control, membrane management, and coordination with unions. Our construction sites are documented, our tests recorded, and our usage advice is personalized to maximize the longevity and performance of your wall-mounted heat pump .

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment