Job sheet · Project

Installation of a Haxxair wall-mounted heat pump in Griffintown (Le Sud-Ouest)

Condo in Griffintown (Montreal): installation of a Haxxair wall-mounted heat pump by AirGreen. Careful installation, gravity drainage, quiet, easy maintenance. Greater Montreal service: Montreal, Laval, Longueuil, North Shore , South Shore .

By AirGreen Climatisation & Chauffage Admin7 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
7 minto read the whole story
–type of installation
2025year published
At a glance

The job on one screen

Installation of a Haxxair wall-mounted heat pump in Griffintown (Le Sud-Ouest)
Installation of a Haxxair wall-mounted heat pump in Griffintown (Le Sud-Ouest)
The full story

The article, chapter by chapter

A targeted comfort upgrade in a Montreal condo: quiet, efficient and designed for everyday use

Project context and comfort objectives

At AirGreen , we were approached by a condo owner in Griffintown who wanted to stabilize the temperature of his open space while reducing his energy costs in both summer and off-season. We offered a Haxxair wall-mounted heat pump , a compact solution that was adaptable to the constraints of a modern building. The main space has a large window dressed with thick curtains, typical of urban condos in central Montreal : it was therefore necessary to optimize the airflow near the window coverings, preserve the aesthetics of the wall, and maintain a minimal noise level.

Why a Haxxair wall-mounted heat pump in a condo?

  • High efficiency in air conditioning mode and supplementary heating in mid-season.

  • Discreet interior module, suitable for low ceilings and light walls.

  • Precise temperature control with integrated display and motorized shutter.

  • Easy maintenance: washable filters accessible from the front, ideal for regular HVAC maintenance by the occupant between our annual visits.

We validate, with a demonstration, the quality of the cold blowing. At the start of the verification, the display shows a set point of 16 °C , and an instant reading with an infrared thermometer measures approximately 13.6 °C at the blowing. This differential confirms good heat extraction from the ambient air and reassures the customer about the real performance of their equipment in condo conditions.

Preparation: route study and integration into the building

Before any HVAC installation , our team carries out a careful survey:

  • Locate the exterior wall aligned behind the wall head to minimize the length of the refrigeration connections.

  • Check for interior obstructions (curtain rods, wall art, soffit corners). We choose a high installation, at a safe distance from the curtains, to avoid any air recirculation and ensure effective cross-sweeping.

  • Condensate drainage path analysis. In a condo, the priority remains gravity flow through a direct wall crossing and a slight slope. We confirm the feasibility; thus, no condensate pump, therefore less maintenance and less noise.

  • Validation of the dedicated power supply and the required circuit breaker, according to the nameplate of the supplied device.

Step-by-step implementation

  1. Controlled drilling of the light load-bearing wall and installation of an insulated wall pass-through.

  2. Installation of the plate and precise leveling to ensure the evacuation of condensates.

  3. Haxxair interior head attachment , seating tests and distance control: lateral curtain clearance and free access to the IR sensor and filter hatch.

  4. Passage of refrigeration connections (insulated copper) and the communication cable. A discreet, light-colored exterior capping ensures UV protection and the aesthetics of the facade.

  5. Brazing and vacuuming : we achieve a deep and stable vacuum, an essential condition for compressor durability and seasonal efficiency.

  6. Pressurization and leak testing .

  7. Start-up and balancing : measurement of delta-T on blowing (reading at ~13.6°C at the register, higher starting environment), adjustment of ventilation parameters and orientation of the flaps.

Aesthetic and acoustic integration

The unit is carefully centered on the wall above the mural. We take into account the passage of curtains: in operation, the shutter directs the airflow towards the open area without hitting the textile. At nominal speed, the perceived noise remains very contained thanks to the balanced fan and the internal insulation of the walls of the Haxxair wall head. In a condo where silence is a major criterion, this point makes all the difference on a daily basis.

Results: measurable comfort and precise control

  • Even cooling of the main room, hallway and dining area thanks to horizontal sweeping.

  • Fast response to the setpoint: the temperature drops steadily then stabilizes without short cycles.

  • Local control by remote control and discreet display on the front: readable even from a distance, practical for confirming the instruction at a glance.

  • Controlled consumption : compressor modulation (inverter) limits electrical peaks and withstands prolonged use during heat waves in Montreal , Laval , Longueuil , North Shore and South Shore .

Maintenance recommended by AirGreen

Preventive maintenance ensures longevity and performance:

  • Every 4 to 6 weeks during periods of heavy use: rinse the filters.

  • Annually : complete inspection by our technicians (electrical tightening, leak test, exchanger cleaning, condensate test).

  • Best practices : keep clearance from the top of the unit and sides, do not obstruct the sensor with curtains or decorative objects, use automatic and dehumidification modes according to indoor humidity.

Special features in co-ownership

In buildings managed by a union, we coordinate:

  • Permission to cross the exterior air barrier and facade rules.

  • The external support (brackets or platform) in compliance with the architectural charter.

  • The hours of intervention and management of common areas to move the equipment without disturbing the neighbors.

Thanks to this preparation, the installation takes place in a single planned visit, with a clean site and immediate return to use.

Choosing the Right Power (BTU) for an Urban Condo

Without oversizing, we estimate the load taking into account:

  • of the open surface,

  • from the sunlight on the windows,

  • of the waterproofing and the level of insulation,

  • of actual occupancy and devices generating internal gains.
    This fine-tuning avoids short cycles, improves comfort and reliability . Our team adjusts the Haxxair selection to the housing profile and, if necessary, suggests adding a second head for a remote room ( MultiZone heat pump configuration possible depending on the building).

Grants and Compliance

Programs evolve and depend on certified performance and equipment type. For a recent range wall-mounted heat pump , eligibility may be considered when the efficiency and low temperature performance criteria are met. We systematically verify these parameters during the submission and provide the required documents. Our advisors support clients in Montreal , Laval , Longueuil , North Shore and South Shore to maximize available assistance.

Practical usage tips

  • During a heatwave, leave early in the day in wall-mounted air conditioning mode and maintain a stable setting.

  • Use the dehumidification mode when the air is heavy; the feeling improves without excessively lowering the setting.

  • Close the blinds during the sunniest hours to limit solar gain.

  • Schedule an HVAC maintenance reminder to maintain performance season after season.

What we deliver at the end of an AirGreen project

  • A clean, aligned and discreet installation, ready to use.

  • Demonstration of essential functions and provision of usage advice.

  • A commissioning report with readings (delta-T, intensities, condensate drainage).

  • Accessible after-sales service with quick appointments throughout Greater Montreal .

In short

In this Griffintown condo, the Haxxair wall-mounted heat pump provides rapid cooling, simple control, and seamless integration into the decor. The 13.6°C blower temperature, combined with precise positioning to avoid curtains, confirms a solution perfectly suited to contemporary urban living. For a similar project—whether you're in Montreal , Laval , Longueuil , on the North Shore , or the South Shore —our team designs and installs an efficient, sustainable solution designed for your space.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).