Project

Installation of a Midea wall-mounted heat pump in Saint-Laurent

AirGreen installs a Midea wall-mounted heat pump in Saint-Laurent, integrated into a complex technical room. HVAC expertise in Montreal, Laval, Longueuil, North Shore and South Shore.

By AirGreen Climatisation & Chauffage Admin4 min read
Installation of a Midea wall-mounted heat pump in Saint-Laurent
Installation of a Midea wall-mounted heat pump in Saint-Laurent
–chapters in this story
4 minreading time
–type of installation
2025year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

A modern HVAC solution adapted to a complex technical space

At AirGreen , we recently installed a Midea wall-mounted heat pump in a building in the Saint-Laurent sector of Montreal. This project perfectly illustrates our expertise in HVAC solutions adapted to technical environments, where space, security, and efficiency constraints must be perfectly balanced. The goal: to provide optimal comfort while harmoniously integrating the equipment into a space already dense with mechanical systems.

Project background

The client contacted us to improve the thermal comfort of a technical room housing several heating and hydraulic control equipment. The space, already occupied by an electric water heater, an expansion tank, a circulation pump and a control panel, required a compact and efficient solution . The Midea wall-mounted heat pump was the ideal choice: quiet, energy-efficient and capable of ensuring precise temperature regulation, even in a light industrial environment.

Machine selection

The Midea wall-mounted heat pump installed in this project offers several advantages:

  • Capacity adapted to the targeted space (9,000 to 12,000 BTU depending on the range chosen).

  • High energy efficiency , meets Energy Star criteria.

  • Reliable operation down to -25°C , ideal for Montreal's climate.

  • Compact design , allowing integration without encroaching on the useful surface area of ​​the premises.

Installation Steps and Challenges

Preparation and integration

Before any installation, our team carried out a complete assessment of the technical room. The main challenges were related to:

  • The density of existing equipment , limiting the space for conduit passages.

  • The need for a secure electrical connection, given the proximity of a panel and regulators already in service.

  • The obligation to maintain easy access to plumbing and heating equipment.

Installation of the indoor unit

The wall unit was mounted high up on a metal wall with a diamond-cut aluminum finish , a solid and durable support. This choice not only provides a professional aesthetic but also increased safety in the event of condensation or splashing.

Connection management

  • The refrigeration pipes have been carefully insulated to prevent any loss of efficiency.

  • The electrical wiring was integrated into a suspended cable tray, ensuring an installation that was both tidy and safe.

  • The condensation drain has been designed to prevent any infiltration into the technical room.

Results obtained

After commissioning, the Midea heat pump demonstrated rapid and stable room temperature regulation. Technicians confirmed:

  • A minimal noise level , essential in a technical room where several pieces of equipment operate simultaneously.

  • Energy stability that helps reduce the load on the building's main system.

  • An immediate improvement in comfort and climate management in the space.

Subsidies and customer benefits

Thanks to its energy efficiency, the installed Midea heat pump is eligible for grant programs such as LogisVert and energy efficiency credits available on the North Shore, South Shore, Laval, and Montreal. Our team assisted the client in preparing the necessary documents, a value-added feature appreciated in this type of project.

AirGreen Expertise

Every HVAC project is unique. In this case, our role was to reconcile a challenging technical environment with performance and comfort requirements. This type of installation demonstrates the importance of calling on a specialized team capable of:

  • Correctly assess the heat load.

  • Identify mechanical and electrical constraints.

  • Offer a reliable and suitable product like the Midea wall-mounted product .

  • Perform a clean, safe and durable installation.


Why choose AirGreen for your HVAC installations in Montreal and its surrounding areas?

We operate in all areas of Greater Montreal —from Laval to the North Shore , including Longueuil and the South Shore —with the same attention to detail and performance. Whether for a condo, a single-family home, or a specialized technical room, we offer customized solutions and provide comprehensive support: installation, HVAC maintenance, and grant support .

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).