Job sheet · Project

Installation of a Sharp Eco Inverter wall-mounted heat pump in Chomedey (Laval)

AirGreen installed a Sharp Eco Inverter wall-mounted heat pump in Chomedey, Laval, optimized for the Quebec climate. Comfort, energy savings, and air purification are all provided, with a complete HVAC service in Greater Montreal.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp Eco Inverter wall-mounted heat pump in Chomedey (Laval)
Installation of a Sharp Eco Inverter wall-mounted heat pump in Chomedey (Laval)
The full story

The article, chapter by chapter

A modern HVAC solution to improve the comfort of a Laval home

At AirGreen , we recently completed a residential installation in Chomedey, Laval , where a client was looking for a reliable solution to ensure year-round comfort. We proposed and installed a Sharp Eco Inverter wall-mounted heat pump , an ideal choice for this type of home thanks to its energy efficiency and durability in the Quebec climate.

Why the Sharp Eco Inverter?

The Sharp Eco Inverter range is distinguished by its Plasmacluster Ion technology, which improves indoor air quality while ensuring efficient heating even during cold winter periods. With a capacity varying according to the number of indoor heads and high efficiency in both heating and cooling mode, it combines comfort, energy savings and sustainability .

  • Inverter technology : power modulation to reduce electricity consumption.

  • Plasmacluster Ion : active air purification, ideal for families sensitive to allergens.

  • Eligibility for subsidies : Hydro-Québec and LogisVert programs when performance conditions are met.

  • Efficiency in cold climates : efficient heating even at -25°C.

Client context and needs

The owner of this home in Chomedey was looking for a versatile solution that could replace an aging backup system while improving air quality. His main goal: to reduce heating costs in the winter while enjoying fresh, filtered air in the summer.

After an energy assessment and inspection of the facade, we recommended the installation of a Sharp Eco Inverter heat pump , perfectly suited to his needs.

Technical details of the installation

Our certified technicians installed the unit on a raised galvanized aluminum support , which protects the outdoor unit from snow and water accumulation in winter.

Some highlights of the installation:

  • Secure mounting : The compressor has been installed on a stable and durable structure.

  • Refrigerant connection routing : short and efficient route to minimize efficiency losses.

  • Electrical wiring : direct connection to the distribution panel, in compliance with the standards of the Quebec Electrical Code.

  • Condensate drainage : gravity installation, avoiding the use of a pump, which reduces maintenance and the risk of breakdown.

  • Optimized location : The outdoor unit has been positioned to ensure good air circulation and easy access for maintenance.

Challenges encountered and solutions provided

Limited outdoor space and proximity to a window presented an installation challenge. To address this, we:

  • chose a suitable support height to free up circulation around the unit;

  • used discreet capping to protect the pipes and preserve the aesthetics of the wall;

  • ensured reinforced insulation of the ducts to maximize energy efficiency.

Results obtained

After commissioning and performance testing, the customer immediately noticed:

  • a significant reduction in interior noise compared to its old system;

  • improved ambient air quality thanks to Plasmacluster technology;

  • efficient heating capacity, promising real savings on the electricity bill .

AirGreen expertise in Laval and Greater Montreal

Each installation is carried out by our qualified teams, with particular attention paid to technical and aesthetic details. At AirGreen , we operate not only in Laval, but also in Montreal, Longueuil, the North Shore and the South Shore , to offer sustainable HVAC solutions adapted to the needs of our customers.


Maintenance and follow-up

We reminded the client of the importance of annual maintenance on their wall-mounted heat pump to maintain energy efficiency and extend its lifespan. AirGreen offers a complete HVAC maintenance service, including:

  • cleaning filters and coils;

  • checking refrigerant pressures;

  • seasonal efficiency monitoring (SEER/HSPF).


Conclusion

The installation of this Sharp Eco Inverter in Chomedey perfectly illustrates our commitment: to offer reliable, energy-efficient and sustainable HVAC solutions , while supporting our customers from the choice of equipment to post-installation follow-up.

With local expertise and a constant focus on quality, AirGreen remains a trusted partner for all your wall-mounted heat pump and HVAC system projects in Greater Montreal.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment