Job sheet · Project

Installation of a Sharp Eco Inverter wall-mounted heat pump in Sainte-Thérèse

AirGreen installs a Sharp Eco Inverter wall-mounted heat pump in Sainte-Thérèse: exceptional performance down to -25°C, energy savings and an aesthetic installation adapted to the North Shore climate.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2025year published
At a glance

The job on one screen

Installation of a Sharp Eco Inverter wall-mounted heat pump in Sainte-Thérèse
Installation of a Sharp Eco Inverter wall-mounted heat pump in Sainte-Thérèse
The full story

The article, chapter by chapter

A reliable and elegant HVAC solution to face the North Shore winters

At AirGreen , we recently installed a Sharp Eco Inverter wall-mounted heat pump in a single-family residence located in Sainte-Thérèse , on the North Shore of Montreal . This project perfectly illustrates our expertise in residential HVAC installation in an environment where harsh winter conditions require efficient, quiet and durable systems.

A wise choice: the Sharp Eco Inverter wall-mounted heat pump

The Sharp Eco Inverter belongs to the new generation of high energy efficiency wall-mounted heat pumps , operating with R-32 refrigerant , which is more environmentally friendly and more efficient than the old R-410A.
This model, known for its Plasmacluster Ion technology , improves indoor air quality by neutralizing particles and allergens. It also ensures stable performance down to -25 °C , making it an ideal option for Sainte-Thérèse winters.

Among its advantages:

  • Quiet operation thanks to its variable speed compressor.

  • Extreme cold heating mode , optimizing interior comfort even in negative temperatures.

  • Inverter technology reducing energy consumption.

  • Plasmacluster filtration providing cleaner, healthier air.

A technical installation adapted to the Quebec climate

This installation has been carefully planned to maximize the durability and operational safety of the system in winter.
The Sharp condenser was securely mounted on galvanized wall brackets , raised to prevent obstruction by snow accumulating on the ground. The refrigerant lines and electrical wiring were routed in gray capping matching the stone facade, ensuring aesthetic integration and complete protection against the elements.

Condensate drainage is carried out by gravity , a preferred method when the configuration allows it, ensuring a smooth flow and without additional pumps. This approach reduces the risk of freezing and simplifies maintenance.

An exemplary residential construction site in Sainte-Thérèse

The AirGreen team completed the installation in a single day, despite challenging winter conditions . Thanks to our careful planning and experience in the northern climate , the project went smoothly:

  • Precise drilling through the stone wall to connect the indoor unit.

  • Reinforced insulation of refrigerant pipes to prevent any energy loss.

  • Complete check of vacuum and refrigerant level before commissioning.

  • Low temperature heating performance test to ensure optimal operation.

Why the Sharp Eco Inverter appeals to North Shore homeowners

The residences of Sainte-Thérèse, Blainville and Boisbriand share the same need: a heating and air conditioning system capable of handling significant temperature variations.
The Sharp Eco Inverter perfectly meets this challenge:

  • Significant energy savings , particularly in self-modulated heating mode.

  • Eligibility for grant programs offered by the Quebec government and Hydro-Québec for high-performance heat pumps.

  • Compact installation , suitable for townhouses or detached pavilions.

An AirGreen commitment: quality, safety and satisfaction

At AirGreen, every installation is carried out according to the highest standards in the HVAC industry :

  • Use of CSA and Energy Star certified materials .

  • Respect clearance distances for optimal airflow.

  • Careful finishing of the fittings and wall fixings.

  • Complete electrical inspection ensuring compliance with the Quebec building code.

We also ensure that our customers understand the operation and maintenance of their new system: regular cleaning of filters, winter clearing around the condenser and annual inspection by our certified technicians.

In conclusion

This Sharp Eco Inverter heat pump installation in Sainte-Thérèse demonstrates our commitment to offering reliable, aesthetic and efficient HVAC solutions, adapted to the climatic realities of Greater Montreal.
Thanks to the precision of our work and the quality of Sharp equipment, the owner now benefits from four-season comfort , controlled energy consumption and purified indoor air — a perfect combination for the Quebec lifestyle.


AirGreen – Your trusted HVAC partner in Montreal, Laval, Longueuil, North Shore and South Shore .
We put our expertise at the service of your comfort, winter and summer.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment