Job sheet · Project

Installation of a Sharp (ZU1 range, R-32) wall-mounted heat pump in Sainte-Julie

Installation of a Sharp R-32 wall-mounted heat pump in Sainte-Julie: wall brackets, black capping, gravity-fed condensate, calibrated commissioning. A meticulous HVAC installation by AirGreen for four-season comfort.

By AirGreen Climatisation & Chauffage Admin6 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
6 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp (ZU1 range, R-32) wall-mounted heat pump in Sainte-Julie
Installation of a Sharp (ZU1 range, R-32) wall-mounted heat pump in Sainte-Julie
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

In a quiet residential area on the South Shore , we are modernizing the comfort of a single-family home in Sainte-Julie with a Sharp ZU1 wall-mounted heat pump using R-32 refrigerant . The goal is clear: efficiently heat the living area in winter, cool it soberly in summer, and preserve the aesthetics of the vinyl facade as well as the tranquility of the neighborhood.

An R-32 solution designed for 4-season comfort

Sharp 's ZU1 range uses a high-efficiency inverter compressor and Plasmacluster air treatment technology. It is ideal for single-family homes: rapid temperature rise, precise power modulation and low consumption when needs are low, especially at night.

The advantages of the range for Sainte-Julie

  • R-32 : better seasonal efficiency and lower global warming potential than previous generations, ideal for energy saving objectives in Montreal , Laval and Longueuil , as well as on the North Shore and the South Shore .

  • Inverter : continuous regulation which avoids jolts and current peaks.

  • Silence : reduced exterior noise level, significant near a terrace and a basement window.

  • Plasmacluster : improvement of indoor air quality when the head operates in recirculation.

Target sizing: a capacity around 12,000 BTU typically covers an open ground floor with kitchen-living-dining room, while remaining economical outside of heat peaks.

Architectural integration: clean, solid and reversible

The outdoor unit is installed on galvanized wall brackets , above the level of the wooden terrace. This installation:

  • frees up ground space and makes snow removal easier in winter;

  • keeps the device away from dirt thrown up by mowing and rain;

  • improves heat dissipation thanks to clearances respected on all sides.

We insert calibrated silent blocks between the device and the brackets to cut off vibration transmission in the structure. The anchors pass through the vinyl siding to take the load in the frame (uprights), with sealing washers and elastomer sealant around each drilling.

Capping and refrigeration process

The main capping , black and UV-resistant , runs vertically along a technical roof downpipe to visually blend into the façade. The lower section, near the terrace, is protected by a clear trunking, which reduces the risk of snagging. The refrigeration lines (high-density insulated copper) and the communication cable are grouped, tied and protected at friction points.

  • Estimated beam length : 4 to 6 meters between inner head and condenser.

  • Bending radii respected at the entrance to the device to preserve the integrity of the tubes.

  • Connection treatment : butyl tape + heat-shrink sleeve for long-lasting protection against water and UV rays.

Condensate drainage: priority to gravity

The interior head is positioned on the courtyard side. The gravity condensate drain exits at the bottom of the wall, under the terrace, with a continuous slope and an outlet protected by a small deflector. No condensate pump here: less maintenance and no risk of additional noise during summer evenings.

Electrical Safety and Compliance

In the immediate vicinity of the condenser, a watertight disconnect switch makes it easy to isolate the unit for maintenance. The dedicated circuit (240 V) is connected via a conduit properly tightened by a cable gland , with clear markings. The height of the disconnect switch is chosen to remain accessible without obstructing passage on the terrace.

Our teams systematically carry out:

  • grounding and checking the circuit breaker rating;

  • checking the tightening of the terminals to the torque;

  • labeling the circuit on the panel to simplify any future intervention.

AirGreen Methodology: from preparation to commissioning

  1. Implementation and validation of clearances (rear, sides and front).

  2. Controlled coring through the insulation and cladding, installation of a waterproof sleeve and a local vapor barrier to prevent infiltration.

  3. Leak tests with dry nitrogen, followed by deep vacuum (< 500 microns) and stabilization.

  4. Opening of the R-32 fluid and commissioning : superheat readings, subcooling , supply/return temperatures, compressor intensity, and recording of values ​​in the customer file.

  5. Finishing touches : alignment of the capping, sealing touch-ups, cleaning of the area, instructions for use.

Result: immediate comfort and preserved facade

The customer benefits from stable heating despite rapid mid-season temperature fluctuations. In summer, the air conditioning reaches the setpoint without unpleasant drafts thanks to fine modulation. Outside, the facade remains clean: aligned black capping , short brackets, and free movement in front of the grille.

Concrete measures observed on site

  • Suitable installation height : fins protected from water accumulation on the terrace.

  • Air discharge management : orientation prevents direct airflow towards the seating area.

  • Maintenance access : all covers and the service valve are clear for quick maintenance.

Best practices for a South Shore home

  • Maintain 30 cm of clear space around the unit and clear snow in winter.

  • Wash the inner head filters every 4 to 6 weeks during peak season.

  • Programming temperature levels (night/day) rather than large differences: this is the strength of an inverter .

  • Avoid objects between the unit and the deck guard that could disrupt airflow.

  • Schedule annual HVAC maintenance : exchanger cleaning, electrical check, pressure and insulation condition verification.

Grants and Eligibility

Depending on the exact capacity and efficiency ratings of the indoor/outdoor unit pair, this heat pump may meet the criteria of active assistance programs in Greater Montreal. We assist with eligibility verification and file preparation for Montreal , Laval , Longueuil , the North Shore and the South Shore (proof of purchase, installation photos, technical sheets).

Small mistakes to avoid (AirGreen feedback)

  • Drilling too low behind a terrace: risk of reversing the slope of the condensates.

  • Undersize the device by prioritizing an entry-level price: the inverter will run at full speed and wear out more quickly.

  • Neglect the acoustic impact on outdoor relaxation areas: it is better to orient the unit and choose suitable pads.

  • Forgetting the accessible disconnect switch: safety and compliance requirement, useful for maintenance.


At AirGreen, we tailor each HVAC installation to the home and the occupants' lifestyle. For a Sharp R-32 wall-mounted heat pump , we combine performance, discretion, and ease of use. Whether you're in Sainte-Julie , elsewhere on the South Shore , in Montreal , Laval , or on the North Shore , our team delivers lasting comfort—documented and easy to maintain.

Keywords worked on : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore .

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).