Installation of a Sharp ZU1 series wall-mounted heat pump in Rosemont–La Petite-Patrie
Rosemont Plex: HVAC installation of Sharp ZU1 wall-mounted heat pumps on brackets with clean capping , R-32 efficiency and four-season comfort. AirGreen operates throughout Montreal and the surrounding area.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A careful HVAC upgrade for a brick plex – four-season comfort, controlled consumption
Building context and objectives
In a typical Rosemont–La Petite-Patrie plex with a brick facade, two apartments seek to gain comfort in both summer and winter, without increasing the electricity bill or distorting the aesthetics. We recommend and install Sharp wall-mounted heat pumps (ZU1 series, R-32 refrigerant) , recognized for their efficiency and reliability in Montreal's climate.
Equipment Choice: Why Sharp ZU1 Series
-
R-32 technology : better environmental profile and higher performance compared to R-410A.
-
Capacity range adapted to Montreal apartments (usual ranges of 12,000 to 24,000 BTU depending on the room).
-
Cold weather performance suitable for Greater Montreal , with useful capacity maintained in negative temperatures, ideal for winter backup.
-
Quiet operation and fine regulation modes for nighttime use.
Desired result: a compact, discreet HVAC installation capable of providing heating and air conditioning all year round, with contained operating costs.
Outdoor installation: clean, robust, durable
We fix each condenser on galvanized wall brackets on the brick.
Notable points:
-
Installation height of approximately 2.5–3 m above the ground to clear traffic areas and limit dust extraction.
-
Continuous and aligned beige capping (horizontal trunk between units and vertical risers), ensuring protection of refrigerant connections and a clean finish.
-
Vibration management using anti-vibration pads and level adjustment using a dynamometer to avoid resonances in the masonry.
-
Service clearances respected: rear and side space for airflow and maintenance.
Route of connections and power supply
-
Neat through- hole with vapor barrier and sealing for airtightness.
-
Optimized line lengths (wall-to-wall connections, estimated short to medium), which reduces load losses and improves efficiency.
-
Dedicated power supply with appropriate circuit breaker, conduits and external cables in sheath; disconnect box positioned within regulatory reach.
Condensate management and interior execution details
-
Gravity evacuation preferred when the slope allows for reliability and silence.
-
When required, condensate pump with silencer and accessible maintenance.
-
Wall-mounted heads positioned for cross-flow airflow, away from obstacles and heat sources.
Multi-housing coordination: two independent zones
The building receives two separate outdoor units , each associated with a dedicated indoor head. Advantages:
-
Independent control for each apartment.
-
Clear billing and personalized settings based on occupancy.
-
Functional redundancy : if one is under maintenance, the other remains operational.
Specific challenges and AirGreen solutions
-
Masonry anchoring : we use a mechanical anchoring system suitable for solid/hollow bricks, with spacers and sealing for a distributed and durable load.
-
Facade aesthetics : choice of matching capping , straight paths, invisible fixings from a distance, passages aligned with architectural lines.
-
Working height : safe intervention on ladders and platforms; tightening torques and pull-out tests carried out.
-
Climate protection : minimal roof overhang clearance and sheathed wiring against snow accumulation and runoff water.
What the customer gains on a daily basis
-
Stable summer/winter comfort thanks to the reversible heat pump mode .
-
Reduced noise inside and out in the backyard.
-
Controlled energy bill thanks to the inverter and good setpoint settings.
-
Simple HVAC maintenance : cleaning filters, annual inspection of connections, checking supports and drain.
Recommended maintenance (annual plan)
-
Spring : cleaning the batteries, checking the condensate flow, checking the capping.
-
Autumn : electrical inspection, tightening, defrosting test, clearing of leaves and vines.
-
Continuous : Internal filters cleaned every 4–8 weeks depending on usage.
Grants and Eligibility
Recent high-efficiency R-32 wall-mounted heat pumps are generally best suited for current programs in Quebec when efficiency and cold weather performance criteria are met. We confirm on a case-by-case basis, prepare proof of installation, and provide certification of specifications.
AirGreen Best Practices for Montreal Plexes
-
Locate holes away from fragile joints and load-bearing elements.
-
Short paths to limit losses; large radius bends.
-
Effective defrosting : respect rear and sub-base clearances for drainage.
-
Winter prevention : tips for clearing snow around units and maintaining a clear space for air intake.
Why choose us?
At AirGreen , we are experts in HVAC installation in dense urban environments: restricted access, old masonry, condominiums. Our team plans, executes and documents each step to deliver a discreet, efficient and durable result — compliant with standards and ready for the extreme cold of Greater Montreal .
Quick Facts
-
Brand / range : Sharp – ZU1 series (R-32 wall-mounted heat pump ).
-
Configuration : two independent single-zone systems.
-
Exterior installation : galvanized wall brackets , aligned beige capping , anti-vibration.
-
Building : brick plex, Rosemont–La Petite-Patrie .
-
Services : HVAC installation , commissioning, HVAC maintenance and energy optimization advice.
And for your project in Montreal, Laval, Longueuil, North Shore or South Shore
We evaluate the heat load , the housing configuration and budget objectives to recommend the most appropriate heat pump (capacity, noise levels, Wi-Fi options, guarantees). We coordinate the installation schedule with the co-owners and provide a completion report useful for grant applications.
Need reliable comfort and a lower bill? We are ready to respond quickly throughout Greater Montreal .
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).