Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
AirGreen installs a Sharp wall-mounted heat pump in a Rosemont plex: position above the window, 12–15 ft run, gravity drain, quiet and efficient. HVAC expertise for Montreal, Laval, Longueuil, North Shore, South Shore .

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Project context: a typical plex, high expectations
In Rosemont–La Petite-Patrie, the owner of a brick plex wanted to modernize his comfort without altering the interior. His goal: efficient supplemental heating , quiet air conditioning for the bedroom and living room, and reduced energy consumption . At AirGreen , we offer an HVAC installation that meets the constraints of Greater Montreal condominiums and optimizes the performance of Sharp brand wall-mounted heat pumps .
Why a Sharp wall-mounted heat pump here?
-
Hot/cold versatility : ideal for mid-seasons and summer heat waves.
-
Energy efficiency : Sharp's recent R-32 ranges offer excellent seasonal coefficients, relevant for assistance programs in Quebec.
-
Silence : very low noise levels on the indoor unit side — crucial in a bedroom.
-
Compact design : perfect above a window, without cutting off natural light.
Our step-by-step installation approach
Study of the locations and choice of location
We position the interior head above the window , about 2.2–2.3 m from the floor. This choice:
-
promotes even air diffusion ,
-
frees up useful wall space,
-
allows a short route of refrigerant connections to the backyard.
Drillings and route of connections
-
Discreet through-hole , made with a controlled slope for gravity drainage of condensates when the configuration allows it.
-
Refrigerant lines and communication cable assembled in a simple capping on the outside, typical total run 12–15 ft to the condenser.
-
Waterproofing : vapor barrier and exterior grade caulking, preventing air and moisture infiltration.
Exterior integration (Montreal backyard)
Space is limited in Rosemont's courtyards. We prioritize:
-
a wall plate with clear height to facilitate snow removal,
-
or a raised slab if the structure requires it,
-
sufficient service length for maintenance without disturbing neighbors,
-
a clearance that meets the standards for air recirculation in heating.
Power supply and protections
-
Dedicated circuit sized according to the nameplate,
-
Code-compliant external circuit breaker and disconnect ,
-
Grounding checked, careful routing to the panel.
Commissioning and calibrations
-
Deep vacuum and leak test,
-
Checking pressures/temperatures in cold and hot modes,
-
Setting the shutters to avoid direct blowing on the bed and reduce drafts,
-
Usage tips: Auto/Heat modes, nighttime temperature management, and filter maintenance.
Result at the customer
Immediate comfort and discreet sound
The Sharp heat pump delivers consistent airflow from the sleeping area to the living area. On a daily basis, the customer benefits from:
-
of rapid cooling during sunny afternoons,
-
efficient heating support in the fall and spring, reducing the number of times the main system starts up,
-
low noise level , compatible with teleworking and sleeping.
Preserved aesthetics
The choice above the window places the head in the most sensitive loss zone , while maintaining a clean appearance . On the exterior, the capping follows the lines of the building for a discreet effect on the brick.
AirGreen technical points and best practices
Sizing and BTUs
We size the capacity according to:
-
the surface area served , the orientation of the windows and solar gains ,
-
insulation (brick walls + lining), infiltration and use (bedroom vs. open area).
A 9,000 to 12,000 BTU is often sufficient for a large bedroom or a closed living room; an open area may require 15,000 to 18,000 BTU . We validate the refrigeration charge and the refrigerant top-up according to the actual length of the lines.
HVAC Maintenance
-
Filters : Rinse with warm water every 4–6 weeks in summer, 8–10 weeks the rest of the year.
-
Exchanger : periodic professional cleaning to maintain performance and air quality.
-
Exterior clearances cleared of snow and debris.
Grants and Eligibility
Recent Sharp R-32 wall-mounted heat pumps , when they meet the performance criteria in extreme cold (≈ −25 to −30 °C) and seasonal efficiency, are often eligible for programs in effect in Quebec (e.g. Hydro-Québec/LogisVert, federal initiatives). We verify each file according to the exact reference and the associated AHRI .
What sets AirGreen apart in Montreal, Laval, Longueuil, North Shore and South Shore
Mastery of Montreal buildings
Plexes and condominiums require:
-
compact paths , fixings adapted to the brick,
-
condensate management without nuisance,
-
respect for the management and the neighborhood.
We coordinate permits, schedules, access to the yard and common areas for a clean and quick installation.
Transparency and monitoring
-
Detailed quote (model, BTU , support options, condensate pumps, capping),
-
Photos of the end of the work and maintenance explanations,
-
Responsive after-sales service throughout Greater Montreal .
Common Mistakes to Avoid (and How We Prevent Them)
-
Undersizing capacity in an open area: we perform a simplified load calculation and validate the actual blowing range.
-
Drilling without drain slope: we check the slope and offer a condensate pump if gravity is not possible.
-
Condenser too low in a snowy courtyard : suitable supports and minimum clearance guaranteed.
-
Lines without continuous insulation : we apply closed and sealed insulation, a guarantee of efficiency in winter.
What if it was at your place?
Whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore , we install Sharp wall-mounted heat pumps with artisanal attention: measured performance , careful aesthetics and clear explanations. At AirGreen, we transform every Montreal building constraint into a sustainable solution .
Installation Quick Facts (Summary)
-
Type : Sharp wall-mounted heat pump ( R-32 refrigerant — recent range)
-
Interior location : above a window, height ~2.3 m
-
Connection route : approx. 12–15 ft , gravity drain preferred
-
Exterior supports : raised plate/slab, snow clearance
-
Objectives : four-season comfort, silence , energy efficiency
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).