Project

Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie

AirGreen installs a Sharp wall-mounted heat pump in a Rosemont plex: position above the window, 12–15 ft run, gravity drain, quiet and efficient. HVAC expertise for Montreal, Laval, Longueuil, North Shore, South Shore .

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Project context: a typical plex, high expectations

In Rosemont–La Petite-Patrie, the owner of a brick plex wanted to modernize his comfort without altering the interior. His goal: efficient supplemental heating , quiet air conditioning for the bedroom and living room, and reduced energy consumption . At AirGreen , we offer an HVAC installation that meets the constraints of Greater Montreal condominiums and optimizes the performance of Sharp brand wall-mounted heat pumps .

Why a Sharp wall-mounted heat pump here?

  • Hot/cold versatility : ideal for mid-seasons and summer heat waves.

  • Energy efficiency : Sharp's recent R-32 ranges offer excellent seasonal coefficients, relevant for assistance programs in Quebec.

  • Silence : very low noise levels on the indoor unit side — crucial in a bedroom.

  • Compact design : perfect above a window, without cutting off natural light.


Our step-by-step installation approach

Study of the locations and choice of location

We position the interior head above the window , about 2.2–2.3 m from the floor. This choice:

  • promotes even air diffusion ,

  • frees up useful wall space,

  • allows a short route of refrigerant connections to the backyard.

Drillings and route of connections

  • Discreet through-hole , made with a controlled slope for gravity drainage of condensates when the configuration allows it.

  • Refrigerant lines and communication cable assembled in a simple capping on the outside, typical total run 12–15 ft to the condenser.

  • Waterproofing : vapor barrier and exterior grade caulking, preventing air and moisture infiltration.

Exterior integration (Montreal backyard)

Space is limited in Rosemont's courtyards. We prioritize:

  • a wall plate with clear height to facilitate snow removal,

  • or a raised slab if the structure requires it,

  • sufficient service length for maintenance without disturbing neighbors,

  • a clearance that meets the standards for air recirculation in heating.

Power supply and protections

  • Dedicated circuit sized according to the nameplate,

  • Code-compliant external circuit breaker and disconnect ,

  • Grounding checked, careful routing to the panel.

Commissioning and calibrations

  • Deep vacuum and leak test,

  • Checking pressures/temperatures in cold and hot modes,

  • Setting the shutters to avoid direct blowing on the bed and reduce drafts,

  • Usage tips: Auto/Heat modes, nighttime temperature management, and filter maintenance.


Result at the customer

Immediate comfort and discreet sound

The Sharp heat pump delivers consistent airflow from the sleeping area to the living area. On a daily basis, the customer benefits from:

  • of rapid cooling during sunny afternoons,

  • efficient heating support in the fall and spring, reducing the number of times the main system starts up,

  • low noise level , compatible with teleworking and sleeping.

Preserved aesthetics

The choice above the window places the head in the most sensitive loss zone , while maintaining a clean appearance . On the exterior, the capping follows the lines of the building for a discreet effect on the brick.


AirGreen technical points and best practices

Sizing and BTUs

We size the capacity according to:

  • the surface area served , the orientation of the windows and solar gains ,

  • insulation (brick walls + lining), infiltration and use (bedroom vs. open area).
    A 9,000 to 12,000 BTU is often sufficient for a large bedroom or a closed living room; an open area may require 15,000 to 18,000 BTU . We validate the refrigeration charge and the refrigerant top-up according to the actual length of the lines.

HVAC Maintenance

  • Filters : Rinse with warm water every 4–6 weeks in summer, 8–10 weeks the rest of the year.

  • Exchanger : periodic professional cleaning to maintain performance and air quality.

  • Exterior clearances cleared of snow and debris.

Grants and Eligibility

Recent Sharp R-32 wall-mounted heat pumps , when they meet the performance criteria in extreme cold (≈ −25 to −30 °C) and seasonal efficiency, are often eligible for programs in effect in Quebec (e.g. Hydro-Québec/LogisVert, federal initiatives). We verify each file according to the exact reference and the associated AHRI .


What sets AirGreen apart in Montreal, Laval, Longueuil, North Shore and South Shore

Mastery of Montreal buildings

Plexes and condominiums require:

  • compact paths , fixings adapted to the brick,

  • condensate management without nuisance,

  • respect for the management and the neighborhood.
    We coordinate permits, schedules, access to the yard and common areas for a clean and quick installation.

Transparency and monitoring

  • Detailed quote (model, BTU , support options, condensate pumps, capping),

  • Photos of the end of the work and maintenance explanations,

  • Responsive after-sales service throughout Greater Montreal .


Common Mistakes to Avoid (and How We Prevent Them)

  • Undersizing capacity in an open area: we perform a simplified load calculation and validate the actual blowing range.

  • Drilling without drain slope: we check the slope and offer a condensate pump if gravity is not possible.

  • Condenser too low in a snowy courtyard : suitable supports and minimum clearance guaranteed.

  • Lines without continuous insulation : we apply closed and sealed insulation, a guarantee of efficiency in winter.


What if it was at your place?

Whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore , we install Sharp wall-mounted heat pumps with artisanal attention: measured performance , careful aesthetics and clear explanations. At AirGreen, we transform every Montreal building constraint into a sustainable solution .


Installation Quick Facts (Summary)

  • Type : Sharp wall-mounted heat pump ( R-32 refrigerant — recent range)

  • Interior location : above a window, height ~2.3 m

  • Connection route : approx. 12–15 ft , gravity drain preferred

  • Exterior supports : raised plate/slab, snow clearance

  • Objectives : four-season comfort, silence , energy efficiency

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment