Job sheet · Project

Installation of a Sharp wall-mounted heat pump in Plateau-Mont-Royal

In Plateau-Mont-Royal, AirGreen installs a Sharp wall-mounted heat pump under the stairs: extended-range wall bracket, clean capping, accessible disconnection and instrumented commissioning. HVAC service in Montreal, Laval, Longueuil, North Shore and South Shore .

By AirGreen Climatisation & Chauffage Admin6 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
6 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp wall-mounted heat pump in Plateau-Mont-Royal
Installation of a Sharp wall-mounted heat pump in Plateau-Mont-Royal
The full story

The article, chapter by chapter

Optimize a narrow space under a metal staircase, without compromising performance or maintenance access

The context of a Plateau plex and our objectives

At AirGreen , we are working in a typical Plateau-Mont-Royal plex: red clapboard side facade, corner brick wall, green metal exterior staircase and narrow courtyard. The owner wants to improve the comfort of the main floor all year round, while keeping the circulation space free and limiting noise pollution in a shared courtyard. We offer a Sharp wall-mounted heat pump (recent range with R-32 refrigerant), known for its fine modulation and its Plasmacluster™ module favorable to indoor air quality.

Choice of equipment and consistency with the home

  • Inverter technology : the machine modulates continuously, which avoids the short cycles that are common in the small volumes of Montreal plexes.

  • R-32 : Reduced charge and better heat transfer than R-410A, with seasonal efficiency gains.

  • Acoustics : Outdoor fan with low profile and quiet mode useful in interior courtyards.

  • Plasmacluster™ : Indoor air purification popular in urban housing with limited ventilation.

Depending on the heated area and the building's permeability, we size the capacity (often 12,000 to 18,000 BTU for an open living area). The goal is to operate mostly at low and medium settings to optimize actual SEER/HSPF and comfort.

Implementation study: constraints and decisions

The site constraints are clear:

  • Narrow space under the stairs;

  • Two materials (cladding and brick);

  • Pedestrian path along the wall;

  • Shared courtyard requiring acoustic vigilance.

Our technical decisions:

  • Fixing on galvanized wall brackets with extended reach , anchored in the load-bearing brick . This configuration clears the floor, frees the passage and guarantees rear/lateral clearances for air intake.

  • High density silent blocks to cut vibration transmission to the masonry (near stairs).

  • Raised height above the ground to protect the device from water and snow accumulations and to facilitate maintenance.

  • Waterproof external disconnect box , positioned to the right of the unit for immediate access during maintenance.

Refrigeration path and power supply

The line set route is short and direct to the indoor area, with wall penetration behind the unit. We form wide bend radii to preserve the integrity of the tubes. The closed-cell insulation is continuous and UV-protected outdoors. The indoor unit drain follows a permanent gravity slope towards the outside; the drilling is inclined to prevent any water backflow.

The power supply is dedicated from the main panel of the dwelling, calibrated according to the nameplate, and protected by a suitable curved circuit breaker. The disconnection is fixed at the regulatory height, wired in conduit approved for outdoor use, with an anti-drip loop before entering the box.

Installation and anchoring: precision and durability

  • Drillings made in the brick with chemical sieves to anchor the stainless steel studs; tightening controlled to the torque.

  • Leveled brackets to avoid mechanical stress on the chassis and to maintain quiet operation.

  • Clearances respected on the sides and front for air circulation, despite the nearby staircase.

  • Corrosion protection on all exposed cuts and fasteners.

Instrumented commissioning

Our commissioning protocol guarantees performance and reliability:

  1. Pressure-controlled nitrogen test on the complete assembly.

  2. Deep vacuum (< 500 microns) maintained without rising during the stabilization period.

  3. Opening and balancing valves ; checking supply/return temperatures.

  4. Manifold readings and clamp thermometry to confirm thermal drift under different fan speeds.

  5. Acoustic control at 1 m and 5 m; adjustments as needed (tightening, leveling, blade/obstacle check).

A commissioning report always accompanies the HVAC installation, with serial numbers, photos and readings.

Results achieved for the client

  • Stable comfort in winter and summer; modulation reduces perceived temperature differences.

  • Lower consumption compared to previous auxiliary heaters thanks to partial load operation.

  • Careful integration : clear passage, clean aesthetics, simplified maintenance thanks to accessible disconnection.

  • Silence in the inner courtyard : choice of night speed and effective anti-vibration support.

Details visible on the installation

  • Framed wall bracket , reach arms adapted to wall and staircase alignment.

  • Clean capping and routing, regular radius, continuous insulation.

  • Disconnection on the right, within easy reach, covered against the weather.

  • Clearance above ground for defrost drainage and no water stagnation.

Good practices and pitfalls to avoid (in dense environments)

  • Anticipate recirculation : avoid directing air discharge towards walls or under an enclosed staircase.

  • Raise correctly : installation that is too low encourages the blades to be buried by snow and freeze.

  • Take care of the drain slope : a drain without slope or one that is too exposed will freeze and can cause overflows.

  • Limit line length : short, isolated routes = better performance and less noise.

  • Observe the clearances required by the manufacturer and by the applicable code for safety and maintenance.

Maintenance and sustainability

Annual HVAC maintenance is recommended:

  • cleaning of interior/exterior exchangers;

  • electrical tightening and checking of intensities;

  • visual inspection of insulation and anchor points;

  • purge and drain test.

We schedule a callback with the client at the beginning of winter and early summer. Keeping the area free of leaves and dust between visits ensures consistent performance.

Yields, operating costs and subsidies

Recent generation R-32 wall-mounted heat pumps offer high mid-season COPs and remain efficient in cold weather. In Greater Montreal ( Montreal , Laval , Longueuil , North Shore , South Shore ), they are generally eligible for assistance programs targeting electrical energy efficiency. We assist the customer in putting together the file (technical certificates, photos, detailed invoice).

Why entrust your Plateau project to AirGreen?

  • Urban expertise : we are familiar with the constraints of alleys, exterior staircases, shared courtyards and mixed brick/cladding walls.

  • Finishing and compliance : dimensioned supports, stainless steel screws, chemical anchors, complete documentation.

  • Local service : teams based in Greater Montreal, rapid interventions and expert HVAC maintenance .

Next step

Whether you are in Plateau-Mont-Royal , Rosemont , Le Sud-Ouest or Ville-Marie , our teams design and build clean, efficient and durable HVAC installations — from selecting the heat pump to final adjustment, including the grant application.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment