Installation of a Sharp ZU1 wall-mounted heat pump in Fabreville (Laval)
Professional installation of a Sharp ZU1 wall-mounted heat pump in Fabreville, Laval, by AirGreen. Energy efficiency, four-season comfort, and a meticulous finish are featured in a family home in Greater Montreal.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Redesigned comfort for a family home in Fabreville
At AirGreen , we recently installed a Sharp ZU1 wall-mounted heat pump in a single-family home in the Fabreville district of Laval . This project perfectly illustrates our expertise in modern HVAC solutions , designed to maximize comfort while reducing energy consumption.
The client wanted to replace an old air conditioning system that no longer met the family's needs, particularly during the hot summers and harsh winters. After analyzing the home's layout and energy priorities, our team recommended the Sharp ZU1 — a wall-mounted R-32 heat pump , known for its reliable performance down to -25°C , quiet operation , and discreet design .
A neat and efficient wall installation
The indoor unit was precisely installed in the main living area, on an interior load-bearing wall , to ensure optimal air diffusion in the living areas. The space available under the ceiling allowed for a compact and harmonious installation, without compromising the aesthetics of the room.
The refrigeration and electrical wiring was carefully concealed using white wall capping , ensuring a clean and professional appearance. Thanks to the direct wall-to-wall configuration , the installation could be completed in a single day, without major structural modifications.
Our team also took care to install a gravity condensate drain , thus avoiding the addition of a pump and ensuring simpler and quieter maintenance.
Why the Sharp ZU1 appeals so much to Laval families
The Sharp ZU1 represents an ideal balance between performance, economy, and reliability. Its variable-speed compressor automatically adjusts power as needed, allowing:
-
a significant reduction in electricity consumption ,
-
extremely low noise level (both indoors and outdoors),
-
and remarkable thermal stability even during sudden temperature variations.
In addition, the R-32 technology used reduces the environmental impact by 68% compared to R-410A, making it an eco-responsible choice for any owner wishing to improve the energy efficiency of their home .
Technical features of the project
-
Installed Model: Sharp ZU1 (12,000 BTU)
-
Unit Type: R-32 Wall-Mounted Heat Pump
-
Location: Fabreville, Laval
-
Installation method: interior load-bearing wall, through-drilling, white capping, gravity drain
-
Project duration: 1 day
-
Number of technicians: 2 AirGreen certified installers
-
Manufacturer's warranty: 10 years on parts, 10 years on compressor
Subsidies and energy efficiency
Thanks to its Energy Star certification and its excellent performance in heating mode down to −25°C, the Sharp ZU1 is eligible for several subsidy programs in Quebec , including those of Hydro-Québec and the Chauffez vert program.
Our advisors support each client in preparing and submitting grant applications , in order to maximize potential savings from the outset.
An AirGreen experience: rigor, transparency and performance
Each AirGreen-signed installation is based on three commitments:
-
A personalized analysis of thermal needs and type of housing.
-
An installation compliant with RBQ and CSA standards , ensuring safety and longevity.
-
Fast and reliable after-sales service , including seasonal maintenance and performance verification.
Our customers in Fabreville immediately felt the difference: a constant temperature, an almost imperceptible noise level, and significantly reduced energy consumption.
The final word: performance and peace of mind
Installing a Sharp ZU1 wall-mounted heat pump with AirGreen means investing in an HVAC system that combines efficiency, durability and absolute comfort .
In the climate of Greater Montreal, where winters can be bitter and summers stifling, this solution represents a strategic choice for improving indoor comfort while preserving the planet.
For any HVAC system installation or replacement project in Laval, Montreal, Longueuil, on the North Shore or the South Shore , our team is ready to support you, from the technical study to commissioning.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).