Installation of a Sharp ZU1 wall-mounted heat pump in Laval
AirGreen installs a Sharp ZU1 wall-mounted heat pump in Laval: energy-efficient R-32 system, installation on wall brackets adapted to snow, comfort and efficiency guaranteed throughout Greater Montreal.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A winter installation optimized for comfort and performance
At AirGreen , we know that indoor comfort shouldn't depend on the seasons. This winter in Laval , our team installed a Sharp ZU1 wall-mounted heat pump , a system renowned for its reliability, energy efficiency, and ability to withstand Quebec's harsh winters. This installation perfectly illustrates our expertise in installing residential HVAC systems in the harsh climates of Greater Montreal.
A typical Laval facade suitable for wall installation
The residence, a single-family home with aggregate siding, required a careful approach to ensure both mechanical stability and winter safety for the outdoor unit. We opted for installation on galvanized aluminum wall brackets , positioned at a sufficient height to prevent obstruction due to snow accumulation. This choice not only ensures better durability , but also optimal ventilation of the condenser throughout the year.
Choosing the Sharp ZU1: a reliable and efficient heat pump
The Sharp ZU1 is one of the brand's newest models, using R-32 refrigerant , which is more environmentally friendly and efficient than the older R-410A gases. This system is designed to provide consistent performance down to -25°C , making it an ideal solution for the Laval climate.
Among its main advantages:
-
High energy efficiency with a SEER that can exceed 23.
-
Quiet operation , both indoors and outdoors.
-
Inverter technology ensuring precise temperature control.
-
Compatibility with provincial grant programs (Hydro-Québec, ÉnerGuide).
By choosing the Sharp range, the owner benefits from a system that is economical , ecological and sustainable , perfectly meeting Quebec energy efficiency standards.
A careful installation down to the smallest detail
Every step of this installation has been designed to maximize system performance. Our technicians have:
-
Drilled the foundation with precision , ensuring a perfectly sealed passage for the refrigerant pipes.
-
Cover the connections with a rigid conduit matching the facade, guaranteeing a clean aesthetic and protection against bad weather.
-
Carried out a precise leveling of the wall structure to ensure natural gravity flow of condensates.
-
Tested and calibrated the operation of the heat pump immediately after switching on, even in negative temperatures.
The indoor unit (not visible here) was installed in a central location on the ground floor, allowing for even heat distribution and efficient cooling in summer.
Why choose AirGreen for your heat pump installation in Laval?
Our expertise is not limited to the installation of equipment. At AirGreen , each installation is preceded by a complete energy analysis of the building and followed by rigorous quality control .
We also support our clients in:
-
Choosing the brand and model best suited to their real needs.
-
Application for available grants (Hydro-Québec, energy-saving programs).
-
Annual maintenance and verification service to ensure the longevity of the system.
This personalized approach allows us to deliver consistent results: optimal comfort, energy savings and peace of mind all year round.
An installation designed for Quebec winters
Installing a wall-mounted heat pump in the middle of winter requires meticulous planning. In Laval, temperatures can quickly drop below -20°C, making every detail crucial: installation height, air clearance, condensate drainage, and frost protection.
Thanks to our experience in the field, we know how to adapt each configuration to the immediate environment - whether it is a bungalow, a duplex or a multi-story house.
Result: comfort, efficiency and peace of mind
Since commissioning, the customer has benefited from stable, quiet and economical heating , even in very cold weather. The Sharp ZU1 perfectly meets the needs of a typical Laval residence: average size, good insulation, moderate consumption and a desire for long-term energy performance.
AirGreen continues to support households in Greater Montreal , from Laval to the South Shore , in their transition to ecological heating and air conditioning solutions.
Each project, like this one, embodies our mission: to offer custom, durable and impeccably executed HVAC installations .
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).
