Job sheet · Project

Installation of a Sharp ZU1 wall-mounted heat pump in Plateau-Mont-Royal

AirGreen installs a Sharp ZU1 A2L wall-mounted heat pump in Plateau-Mont-Royal: quiet diffusion, high efficiency, discreet finishes and complete HVAC maintenance for Montreal, Laval, Longueuil, North Shore and South Shore.

By AirGreen Climatisation & Chauffage Admin6 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
6 minto read the whole story
–type of installation
2025year published
At a glance

The job on one screen

Installation of a Sharp ZU1 wall-mounted heat pump in Plateau-Mont-Royal
Installation of a Sharp ZU1 wall-mounted heat pump in Plateau-Mont-Royal
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

A recent indoor head with A2L refrigerant for precise, discreet and eco-efficient comfort in a Montreal condo

Project context and objectives

In a condo in Plateau-Mont-Royal , we are modernizing comfort with a Sharp ZU1 series wall-mounted heat pump operating with a new generation A2L refrigerant. The mandate is clear: to obtain stable heating in winter, fine cooling in summer, clean visual integration and minimal noise levels to respect the co-ownership lifestyle. We organize the HVAC installation to limit visible perforations, preserve aesthetics and maximize performance over four seasons in Montreal .

Why Sharp's ZU1 range for this condo?

The Sharp ZU1 is a recent generation using low GWP A2L refrigerant and inverter technology . This results in:

  • precise power modulation to match the actual room load;

  • excellent energy efficiency and long, smooth cycles;

  • an operating range designed for the extreme cold of Greater Montreal;

  • a compact, quiet design adapted to the typical ceiling heights of condos.

AirGreen Approach : We size BTU capacity based on actual room heat loss, solar orientation, glazing, and airtightness. The goal is not to add BTUs "just to be safe," but to achieve the perfect balance between comfort and consumption.

Implantation of the inner head: precision and compliance with clearances

The wall-mounted fan is installed high under the ceiling to promote controlled air stratification and diffusion throughout the living area. We comply with:

  • the top and side clearances prescribed by the manufacturer to prevent any recirculation;

  • rigorous alignment with the load-bearing wall, so as to limit vibrations;

  • a rear path of the connections for a clean finish in the room.

The motorized shutter is set for a wide vertical sweep in cooling mode and a gentle throw in heating mode, to avoid drafts in the occupied area. The filters are accessible without removing the facade, which facilitates periodic HVAC maintenance by the occupant.

Refrigeration, electrical and condensate connections: an optimized route

For the technical part, we are setting up a short and streamlined route :

  • Continuously insulated copper refrigeration lines , capped to the outside exit point;

  • Bending radii respected on the bend to protect the copper core;

  • Communication and power wiring in a dedicated conduit, with circuit breaker in accordance with the nameplate and electrical code;

  • Condensate drainage primarily by gravity with a regular slope; if the architecture requires it, integration of a silent lifting pump , accessible tray and non-return valve.

Good practice in condos : the route must limit the crossing of spacers and noise-sensitive areas. Our team favors existing technical walls and short paths , guaranteeing long-term reliability and minimal pressure losses.

Drilling and sealing of the envelope

The main drilling is made to the adjusted diameter , with a sheath , low-expansion foam and a membrane for air/vapor barrier continuity. On the exterior, the capping is chosen in white to blend in with the light facades and the joinery of the condo. Each joint receives a polyurethane sealant resistant to UV and freeze/thaw.

Commissioning: instrumented controls and traceability

Commissioning follows a strict protocol:

  1. Nitrogen test with stabilization and survey;

  2. Deep vacuum draw , followed by a lift test ;

  3. Load opening and verification of subcooling/superheating under real conditions;

  4. Electrical checks (continuity, tightening, currents);

  5. Setting up instructions and nighttime silent mode;

  6. Delivery of a commissioning sheet (serial numbers, measurements, key photos) useful for the warranty and subsidies when applicable.

Results obtained after adjustments

From the first cycles, the temperature stabilizes quickly with minimal noise . The blowing is uniform, without disturbing air currents in the dining area. In heating mode, the inverter control maintains a regular comfort curve and limits humidity variations. The consumption measured in mid-season is significantly lower than with traditional electric baseboard heaters.

HVAC Maintenance: Actions That Prolong Performance

To maintain the performance of the wall-mounted heat pump , we recommend:

  • Clean the filters every 4 to 8 weeks during periods of use;

  • Annual inspection by our technicians: electrical tightening, condition of insulation, cleanliness of coils, verification of load by indirect measurements and reading of currents;

  • Control of free flow of condensates (slope, siphon, pump if applicable);

  • Checking the remote control and resetting seasonal time slots .

AirGreen Tip : A clogged filter increases consumption and reduces heating capacity in cold weather. Simple, regular maintenance ensures consistent comfort and extends the life of your equipment.

A2L Grants, Compliance and Security

Recent high-efficiency heat pumps using A2L refrigerant may be eligible for financial assistance when they meet performance and installation criteria. We support our customers in:

  • eligibility verification (model, climate zones, photographic evidence);

  • preparation of files (detailed quote, serial numbers, standardized invoice);

  • monitoring of requests until payment.

In terms of safety, the installation complies with the prescribed ventilation distances , the absence of nearby ignition sources and the use of A2L compatible components. Our teams are trained in A2L good practices for soldering, evacuation and recovery of fluids.

Key points addressed on this project

  • Precise sizing : capacity adapted to the part avoiding short cycles;

  • Short path of connections to limit losses;

  • Compliant blowing and suction clearances ;

  • Clean finishes (hoods, seals, alignments) for discreet integration;

  • Optimized noise level thanks to night mode and the anti-vibration support of the associated outdoor unit.

Usage tips for the owner

  • Use stable settings (heating/cooling) rather than frequent variations;

  • Activate dehumidification mode on humid summer days;

  • Keep obstacles away from the air outlet and return air;

  • Program silent mode for nighttime hours if necessary;

  • Schedule annual maintenance in spring or early fall to prepare for the following season.

AirGreen Service in Greater Montreal

We respond quickly to Montreal , Laval , Longueuil , as well as the North Shore and the South Shore . Our team manages the entire cycle: audit , equipment selection , HVAC installation , commissioning , HVAC maintenance and priority troubleshooting for our contracted customers.

Balance sheet

The installation of this Sharp ZU1 in a condo in Plateau-Mont-Royal illustrates our way of working: pragmatic engineering , careful finishing, strict compliance with A2L standards and complete support for performance and durability . The result: precise comfort, better controlled bills and aesthetic integration in line with co-ownership requirements.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment