Installation of a Sharp ZU1 wall-mounted heat pump in Plateau-Mont-Royal
AirGreen installs a Sharp ZU1 R-32 wall-mounted heat pump on a flat roof in Plateau-Mont-Royal: raised frame, anti-vibration pads, UV cladding and careful commissioning. Four-season comfort for Montreal, Laval, Longueuil, North Shore and South Shore.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A flat roof installation designed for the Montreal climate: performance, silence and safe maintenance access
Customer situation and expectations
At AirGreen , we are working in a plex in the Plateau-Mont-Royal where the owner wants to replace an old unit with a newer, more efficient wall-mounted heat pump that can economically heat a large living area upstairs. The site's constraints include a gravel roof, ladder access, existing wiring passages that need to be streamlined, and a requirement for very low noise levels to preserve the peace and quiet of the backyard neighbors.
Equipment selection: Sharp ZU1 R-32, single zone
We are retaining a Sharp unit from the ZU1 family operating on R-32 in a single zone configuration. This range combines high efficiency inverter , Plasmacluster filtration and stable operation in cold weather, ideal for winters in Montreal , Laval and the North Shore/South Shore .
Highlights of the Sharp ZU1 range
-
Fine modulation of the compressor to limit on/off cycles and reduce consumption.
-
Optimized exchangers and intelligent defrosting to maintain capacity at low temperatures.
-
Compact outdoor unit, easy to integrate on flat roofs with regulatory clearances.
-
Advanced filtration inside, beneficial for air quality.
Sizing note: the capacity is adjusted after calculating the loads (envelope, orientation, infiltration). We thus validate the BTU power best suited to the area served, without oversizing.
Roof preparation and safety logistics
Before installation, our team secures access and prepares the workstation:
-
Bituminous membrane protection with high density pads under the rails.
-
Access path marked to avoid any puncture of the roof.
-
Check the clearances around the future base to ensure optimal air circulation and free flow of defrosting.
External mounting: raised and anti-vibration structure
The Sharp outdoor unit sits on a raised aluminum frame anchored to two rails resting on anti-perforation roof supports . Anti-vibration mounts mechanically isolate the unit, limiting the transmission of vibration to the structure and adjoining masonry.
Execution details
-
Useful height calculated to keep the unit above the accumulation of blown snow.
-
Level controlled on both axes to ensure correct oil return and good defrost flow.
-
Orientation studied to protect the condenser from prevailing winds and prevent air recirculation.
Refrigeration path and power supply
The shortest route is chosen between the inner head and the condenser:
-
Continuously insulated copper connections up to the parapet, protected by UV cladding then by waterproof flashing at the crossing.
-
Stainless steel fasteners and anti-friction collars to withstand freeze/thaw cycles.
-
External disconnect box accessible near the device, wiring in cold-resistant conduit, grounding verified.
This streamlining of the route reduces pressure losses, improves yields and facilitates HVAC maintenance .
Indoor unit: measurable comfort and discreet integration
The wall head is positioned to sweep the main open area. Objectives achieved:
-
Increased thermal homogeneity thanks to horizontal/vertical scanning.
-
Better controlled humidity in summer, avoiding the feeling of heavy air.
-
Acoustic discretion, even at high ventilation speed.
The condensate drain is entrusted to gravity with a continuous slope; a flow test is carried out before closing the covers to eliminate any risk of backflow.
Commissioning: AirGreen protocol
Our technicians apply a rigorous protocol:
-
Calibrated flares , tightening torques checked with a torque wrench.
-
Nitrogen + bubbling for initial leak test.
-
Deep vacuum until stabilization, then hold to detect micro-leaks.
-
Inverter settings, current checks, overheating/subcooling and ventilation balancing.
-
Defrost test and water drainage check on the roof.
Each measurement is recorded for traceability and warranty.
Results observed on site
-
Smooth start and very low noise pollution on the stage side.
-
Hot/cold delivered quickly, without sudden temperature variations.
-
No water backflow on the membrane; the flow is away from the passage areas, avoiding the formation of ice.
Best practices for Montreal flat roofs
-
Clear clearances on at least 3 sides; avoid corners that recirculate air.
-
Sufficient height to take into account accumulated snow and spring runoff.
-
Snow guards or deflectors if exposed to snow drifts.
-
Suitable membrane fixings and protections ; avoid any direct anchoring that would pierce the waterproofing.
-
Passage of connections on trestles or rigid cover to avoid crushing under the snow.
Recommended maintenance
To maintain the efficiency of the heat pump :
-
Periodic cleaning of the internal filters and dusting of the exchanger.
-
Annual inspection of the roof unit: fins, defrost tray, tightness of connections, condition of anti-vibration mounts .
-
Clearing leaves in the fall and monitoring after heavy snowfall.
-
Checking the exterior cladding and parapet seals.
These operations limit consumption and extend the life of the compressor.
Grants and Eligibility
The R-32 and inverter modulation combination places this project within the configurations generally eligible for incentive programs for efficient wall-mounted heat pumps . We support our clients to validate the criteria, prepare the file and coordinate the request, whether you live in Montreal , Laval , Longueuil , the North Shore or the South Shore .
What makes the AirGreen difference
-
Custom design of the refrigeration path to minimize lengths and bends.
-
Aesthetic integration : matching covers, clean management of drilling and sealing.
-
Documented quality procedures at each stage, guarantees of reliability and guarantees respected.
-
Fast local service for maintenance and seasonal interventions throughout Greater Montreal.
Site sheet — technical summary
-
Type : Single-zone wall-mounted heat pump , R-32 refrigerant
-
Location : Flat gravelled roof, raised frame with roof supports and anti-vibration mounts
-
Route : short connections, UV cover up to the parapet, waterproof flashing
-
Power supply : external disconnect, frost-resistant conduit, controlled earthing
-
Client objective : economical additional heating and quiet air conditioning of an open area
For your flat roof building
Whether your project is in Plateau-Mont-Royal , Villeray , Laval-des-Rapides or Saint-Lambert , we bring the same rigor: thermal study, selection of a new generation Sharp model with R-32 , high-end HVAC installation and annual HVAC maintenance . Stable comfort all year round, a controlled bill and installation that respects your roof.
Upgrade to lasting, quiet comfort
We schedule the visit, verify the heat load, size the unit, and deliver a clean site with secure maintenance access. Your heat pump works for you, discreetly, in the bitter cold and in the heart of Montreal's summer.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).