Job sheet · Project

Installation of a Sharp ZU1 wall-mounted heat pump in Rosemont–La Petite-Patrie

Sharp ZU1 R-32 wall-mounted heat pump installed in Rosemont–La Petite-Patrie: bracket installation, anti-vibration, careful capping and disconnect box. AirGreen, HVAC installation experts for Montreal, Laval, Longueuil, North Shore and South Shore.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp ZU1 wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Sharp ZU1 wall-mounted heat pump in Rosemont–La Petite-Patrie
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Clean and quiet HVAC integration on a Montreal balcony

In Rosemont–La Petite-Patrie , we installed a Sharp ZU1 wall-mounted heat pump ( R-32 refrigerant) on the brick facade of a typical plex. The goal: to provide four-season comfort without encroaching on the balcony's living space and while respecting the clearances around a large patio door .

Building context and installation logic

The building has a red brick facade with a wooden balcony and metal railing . We fix the outdoor unit on wall brackets above the floor, with anti-vibration pads to preserve the peace of mind of the occupants and neighbors. This height protects the unit from water accumulation and facilitates maintenance.

Why the Sharp ZU1 for this project

The Sharp ZU1 combines Eco Inverter and Plasmacluster ionization , ideal for a family apartment:

  • Reliable heating until the bitter cold, for stable comfort in Montreal winters.

  • Precise air conditioning in summer, with fine modulation to reduce on/off cycles.

  • Improved air quality thanks to Plasmacluster.

  • R-32 refrigerant with lower GWP than R-410A, aligned with recent requirements.

Refrigeration and finishing

The discreet capping runs vertically along the facade, then crosses a small radius near the service box before entering the interior. The two insulated connections and the communication cable are grouped, sealed, and secured at regular intervals for a durable hold.

  • Single hole with weatherstripping sleeve and peripheral sealant.

  • Disconnection box in the immediate vicinity for the dedicated power supply , compliant with RBQ and maintenance regulations.

  • Condensate management by natural slope towards the outside (gravity drain), avoiding the addition of a pump in this context.

Points of attention near a patio door

Installing a heat pump next to a large bay window requires careful planning:

  • Blow-out clearance : The unit is positioned to prevent air recirculation against the glass.

  • Access : free passage for opening the door and moving around on the balcony.

  • Noise : Place on pads and tighten the fixings to the correct torque to limit vibration transmission to the guardrail.

  • Defrosting : clearance under the appliance so that defrost water can drain away without stagnating on the decking.

Sizing and expected performance

We size the BTU capacity according to the orientation, insulation and actual volume of the rooms served. The ZU1 offers a competitive COP in mid-season and maintains good useful power in both cooling and heating, reducing the use of electrical backup. Result: energy savings and stable comfort .

Grants and Compliance

The Sharp ZU1 R-32 meets the high-efficiency criteria generally required by Quebec programs. Customers in Montreal, Laval, Longueuil, North Shore, and South Shore may be eligible for financial assistance (depending on files and certified versions). We assist in the preparation of documents and certificates.

Recommended HVAC maintenance

To preserve the longevity of the installation:

  • Cleaning of filters and inspection of ventilation rollers of interior heads.

  • Annual check of electrical connections and refrigeration tightening .

  • Seasonal clearance around the unit (leaves, snow).

  • Checking the torque of the anchors and the condition of the capping after freezing/thawing.

Common mistakes avoided on this job site

  • Undersizing in a very glazed room: here, the load was validated with realistic margins.

  • Air recirculation due to positioning too close to the glazing: corrected by careful alignment and orientation of the fan.

  • Vibrations transmitted to the balcony: neutralized by pads and spacers, plus a detailed check of the fan imbalance.

The result for the customer

A silent , aesthetic and easily accessible system for service, which improves comfort throughout the year. The installation respects the architecture of the plex and secures long-term operation.

AirGreen: the benchmark in HVAC installation in Montreal

Our team is adept at HVAC installations in confined urban environments: plexes, condominiums, narrow streets, balconies and brick facades. We deliver clean , standardized and durable installations, with usage advice, maintenance schedules and assistance with grants .

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).