Stable performance in winter, silence in summer and impeccable finishes: we signed a clean and durable HVAC installation of a Sharp wall-mounted heat pump on a single-family home in Sainte-Thérèse (North Shore).
A pose designed for the climate of Greater Montreal
The owner wanted an efficient heating/cooling solution for the main living area, with a clear priority: reliability in winter and noise discretion for neighbors. We recommend a Sharp ZU1 (R-32) series wall-mounted heat pump, modulating Inverter , designed for the rapid temperature variations typical of the North Shore . This family is distinguished by:
- 
wide modulation, ideal for avoiding short cycles;
 - 
good seasonal performance and contained acoustics;
 - 
defrosting electronics optimized for Quebec winters;
 - 
 
simple maintenance (accessible casings, protected exchanger).
 
Our mandate: to deliver a neat , durable installation that complies with local electrical regulations, without compromising on aesthetics or performance.
Outdoor installation: concrete base + snow-free base
To protect the unit from snow accumulations and splashes, we place the condenser on:
- 
a concrete slab on a compacted bed, sized for load and freeze-thaw;
 - 
a raised galvanized steel stand , which places the bottom of the unit well above the snow line and makes defrosting easier ;
 - 
 
anti-vibration pads to reduce the transmission of vibrations to the structure.
 
This slab + base combination stabilizes the equipment, improves drainage under the unit and reduces structure-based noise perceived inside.
Connection path: discreet and watertight vertical capping
We favor the shortest possible path between the inner head and the condenser. Here:
- 
the refrigeration lines , the communication cable and the drain exit through the wall just behind the unit;
 - 
 
a beige exterior capping (aligned with the color of the coating) runs vertically up to the device, providing UV protection and watertightness ;
 - 
the whole thing is sealed with a multi-layer caulking (air barrier + insulation), preventing infiltration and thermal bridges .
 
Estimated total length: 3 to 5 m , ideal for keeping pressure losses low and simplifying maintenance.
Power supply: safety, compliance, service
The outdoor unit is powered via:
- 
 
a disconnect box mounted nearby (direct access for maintenance);
 - 
a dedicated circuit sized according to the machine nameplate;
 - 
a clean cable route, with drop loop to protect connections.
 
This configuration ensures rapid power off during interventions and meets the requirements of current electrical codes .
Condensate management and winter protection
On wall installations, drainage is a critical point. We have:
- 
provided gravity flow from the inner head to the outer (quiet, reliable);
 - 
 
validated a continuous slope > 1%, tested by filling ;
 - 
left inspection access for the next HVAC maintenance .
 
On the exterior side, the ground clearance and orientation prevent the formation of harmful ice cubes during defrost cycles.
Controlled acoustics, respected neighborhood
The positioning takes into account:
- 
openings (neighboring windows) and reverberation on the facing;
 - 
from the discharge of free air in front of the exchanger;
 - 
distance from sensitive areas (terrace, bedroom).
 
The Sharp heat pump 's inverter modulation limits the speed increases: in practice, the unit runs for a long time at a low noise level , which reduces the acoustic footprint in the evening and mechanical fatigue .
Interior: even diffusion and everyday comfort
The wall head (Sharp range) is placed at a height for:
- 
capture hot air from the ceiling in winter and efficiently recycle the volume;
 - 
project fresh air beyond the living area in summer, without blowing directly onto the occupants;
 - 
reduce stratification and improve comfort humidity during humid periods.
 
Motorized shutters allow you to adjust the sweep ; we set simple scenes (Day/Evening/Night) in order to reconcile energy savings and thermal stability .
AirGreen commissioning
Each installation comes with a complete commissioning protocol :
- 
Extended vacuum and nitrogen leak test .
 - 
Checking refrigeration parameters (superheating/subcooling) according to ambient temperature.
 - 
 
Checking the currents , tightening the terminals and testing the disconnection box .
 - 
Calibration of the shutter and adjustment of the instructions to limit the cycles.
 - 
Customer training: filter cleaning, seasonal best practices and HVAC maintenance plan.
 
Recommended HVAC maintenance
To maintain performance year after year:
- 
Filters : clean every 4 to 8 weeks during use;
 - 
Annual inspection : coil, fan, condensate pan, electrical tightening, probe testing;
 - 
 
Checking capping and caulking after winter (freeze-thaw);
 - 
Minimum clearance around the condenser: keep grass and vegetation free to ensure air exchange.
 
Regular maintenance maintains performance and protects the manufacturer's warranty .
Grants and Eligibility
Recent, high-efficiency R-32 wall-mounted heat pumps may be eligible for certain current assistance. Eligibility depends on the performance coefficients and the heating operating range . When providing a quote, we validate the applicable criteria for Montreal , Laval , Longueuil , the North Shore and the South Shore , and provide, if necessary, the required technical documents .
Pitfalls avoided by our team
- 
 
Leaky drilling → risk of infiltration: we apply an air barrier and a sealant suitable for the coating.
 - 
Lines too long → pressure losses, noise: we limit the distance and optimize the curvature radii .
 - 
Ground level device → snow, corrosion: the raised support prevents burial and extends the service life.
 - 
Drain without slope → drops, odors: the gravity slope is measured and tested.
 - 
 
Wiring without disconnection → difficult maintenance: the dedicated box is installed within easy reach.
 
Result at Sainte-Thérèse
- 
Stable comfort in the living area, summer and winter;
 - 
Controlled outside noise , respect for neighbors;
 - 
Clean finishes : integrated beige capping, clean wiring, durable panel and support;
 - 
Optimized service access : disconnection and standard clearances.
 
AirGreen, your local HVAC partner
We support residential owners and managers in Montreal , Laval , Longueuil , on the North Shore and the South Shore . Our added value: rigorous sizing , clean execution , documented commissioning and clear maintenance monitoring . 
Are you planning to install a Sharp wall-mounted heat pump or equivalent? We will assess the installation (base, height, air discharges), the routing of the connections , condensate management and the acoustic constraints of the neighborhood on site.
Naturally integrated keywords : heat pump , wall-mounted heat pump , HVAC installation , HVAC maintenance , Sharp , R-32 , Montreal , Laval , Longueuil , North Shore , South Shore , Sainte-Thérèse .