Installation d’une thermopompe centrale FUJITSU CENTAURI R32 3 tonnes (36 000 BTU) à Longueuil
Reading time: 5'

Installation of a FUJITSU CENTAURI R32 3-ton (36,000 BTU) central heat pump in Longueuil

A complete transformation of residential comfort thanks to perfectly mastered HVAC installation

In Longueuil, in a residential area of modernized 1980s single-family homes, we recently completed a complete HVAC installation of a FUJITSU CENTAURI R32 36,000 BTU (3-ton) central heat pump. This project perfectly illustrates the importance of sizing, air distribution, and quality of execution to achieve real, stable, and lasting comfort.

Behind this installation was a classic problem in the South Shore region: marked temperature differences between the ground floor and the upstairs, inefficient air conditioning during heatwaves, and an aging, underperforming heating system in winter.

Why this choice: a FUJITSU central heat pump adapted to Longueuil's climate

A machine designed for Quebec conditions

The FUJITSU CENTAURI R32 3-ton is a particularly interesting central system for homes with existing ductwork. It offers an excellent balance of performance, stability, and energy efficiency.

Here are the key characteristics of the installed system:

  • Capacity: 36,000 BTU (3 tons)
  • Refrigerant: R-32 (new generation)
  • Certification: ENERGY STAR® (including cold climate)
  • AHRI: 217290596
  • Effective heating temperature: down to -21°C
  • SEER2: 17.6+
  • HSPF2: 9.8+
  • Voltage: 220V
  • Outdoor sound level: approximately 56 dB(A)
  • Piping: 3/8 - 5/8
  • LogisVert subsidy: up to $3,288

This machine perfectly meets the current requirements of Longueuil homeowners, who are looking for a high-performance heat pump that is eligible for subsidies and reliable in the long term.

A strategic choice based on the actual dwelling

Unlike a generic approach, we took the time to analyze:

  • The house's partial insulation
  • The existing ductwork network
  • Wind exposure
  • The room configuration (open-plan vs. closed bedrooms)

This preliminary work allowed us to confirm that the 3-ton size was perfectly suitable, thus avoiding common oversizing errors.

Challenges encountered on the Longueuil site

Confined outdoor space

The outdoor unit, visible in the photo, was installed on a raised base specially designed to:

  • Prevent snow accumulation
  • Reduce vibrations
  • Ensure optimal drainage

Its positioning under an existing structure (such as a balcony or roof overhang) required particular attention to ensure:

  • Good air circulation
  • Easy access for HVAC maintenance
  • Compliance with recommended clearances

Ductwork network optimization

One of the major challenges of this project was air distribution:

  • Some rooms received too much airflow
  • Others were under-supplied

We proceeded with:

  • Complete duct balancing
  • Register adjustment
  • Validation of air returns

Result: a uniform temperature throughout the house, without excessive energy consumption.

AirGreen installation process: rigor and precision

Key steps performed

Here's how we carried out this central heat pump installation in Longueuil:

  1. Complete on-site inspection
    • Thermal analysis
    • Duct verification
    • Electrical validation (MCA/MOP)
  2. Site preparation
    • Surface protection
    • Piping route planning
  3. Outdoor unit installation
    • Anti-vibration support
    • Perfectly adjusted level
    • Optimized clearance
  4. Indoor unit installation (AMUH36KUAS)
    • Integration into the duct system
    • Hermetic connection
  5. Vacuum pull (micron test)
    • Complete moisture removal
    • System airtightness validation
  6. Commissioning and calibration
    • Fan speed adjustment
    • System parameterization

A start-up often overlooked... but essential

A poorly adjusted central heat pump can lose a large part of its efficiency. At AirGreen, we place particular importance on this step:

  • Precise airflow adjustment
  • Thermostat calibration
  • Real-world condition tests

Final result: transformed comfort

After installation, the changes were immediate:

  • Stable temperature in all rooms
  • Significant noise reduction
  • Improved nighttime comfort
  • Decreased thermal variations

The client particularly noted that the upstairs bedrooms, previously problematic, are now perfectly comfortable, summer and winter alike.

What homeowners absolutely need to know before installing a central heat pump

Frequent mistakes to avoid

Even with an excellent machine like Fujitsu, certain errors can compromise the results:

  • Ignoring the condition of existing ducts
  • Neglecting air returns
  • Installing the outdoor unit too close to the ground
  • Omitting the final adjustment

Practical advice

To maximize your investment:

  • Always have the sizing validated
  • Request a complete duct inspection
  • Ensure the installer performs a micron test
  • Opt for a contractor specializing in complete HVAC installation

Subsidies and profitability in Longueuil

This installation is eligible for the LogisVert subsidy, which can reach $3,288, significantly reducing the total cost.

In a context of rising energy costs, an efficient central heat pump allows for:

  • Reduced consumption
  • Improved property value
  • Increased daily comfort

Why choose AirGreen for your project in Longueuil

At AirGreen, we don't just sell machines. We deliver complete systems, adapted to each home.

Our commitments:

  • Free on-site estimate
  • Full price transparency
  • Professional installation
  • Payment only upon completion of work
  • Service throughout Montreal, Laval, Longueuil, North Shore, and South Shore

Every project is treated with the same level of demanding standards, whether it's a small wall-mounted heat pump or a 36,000 BTU central unit.

An ideal solution for Longueuil homes

The FUJITSU CENTAURI R32 central heat pump is particularly suitable for:

  • Houses with existing ductwork
  • Families seeking uniform comfort
  • Homeowners desiring a durable and high-performance solution

In this project in Longueuil, it demonstrated its full potential: stable performance, real comfort, and perfectly successful integration.

Leave a comment