Project

Installation of a Lennox central heat pump in Rosemont–La Petite-Patrie

Discover this Lennox central heat pump installation carried out by AirGreen in Rosemont–La Petite-Patrie, a reliable and efficient solution perfectly suited to Montreal residences.

By AirGreen Climatisation & Chauffage Admin3 min read
Installation of a Lennox central heat pump in Rosemont–La Petite-Patrie
Installation of a Lennox central heat pump in Rosemont–La Petite-Patrie
Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

As part of a residential project in Rosemont–La Petite-Patrie , our AirGreen team completed the installation of a Lennox central heat pump in a typical Montreal building, complete with a stone basement, existing ductwork, and significant mechanical constraints. This type of configuration is common in this area and requires a methodical approach to ensure performance, reliability, and compliance.


A central system adapted to Montreal residences

The installed unit is a Lennox central heat pump , a choice renowned for its robustness, consistent heating and cooling performance, and seamless integration with existing ductwork. In this project, the system replaces older, less efficient equipment while maintaining the existing air distribution network architecture.

Central heat pumps are particularly well-suited to homes in Rosemont, where you often find:

  • narrow technical basements,

  • masonry or stone walls,

  • existing metal conduits to be optimized rather than rebuilt.


Lennox central model – high-performance residential range

Even though the exact model isn't clearly displayed, the equipment is clearly a recent Lennox residential-grade central heat pump , compatible with current energy efficiency standards. This type of Lennox system is designed for:

  • to provide stable heating during the Quebec winter ,

  • to ensure uniform air conditioning in the summer ,

  • to operate silently despite installation in a confined space.

Lennox remains a highly regarded brand for the quality of its components, the longevity of its indoor units, and the reliability of its electronic controls.


Installation details observed on the construction site

The installation, visible in the photos, highlights several important technical elements:

  • Vertical central indoor unit , installed on a solid base in the basement.

  • Direct connection to existing ducts , with a well-sealed metal plenum to limit air loss.

  • Insulated refrigeration line , carefully protected along its entire height to prevent condensation and heat loss.

  • Proper management of the mechanical space , despite stone walls and a configuration typical of old Rosemont buildings.

  • Clear access for maintenance , an essential point for the durability of the Lennox system.

This type of installation requires specific expertise: every connection, every duct transition and every insulation detail has a direct impact on comfort and energy consumption.


Why a Lennox central heat pump in Rosemont?

In a densely populated area like Rosemont–La Petite-Patrie, homeowners are primarily looking for:

  • consistent comfort across all floors ,

  • a discreet solution , without visible wall units,

  • a reduction in energy costs ,

  • a reliable system to face Montreal winters.

The Lennox central heat pump perfectly meets these requirements, especially when installed and calibrated by a team that is familiar with the realities of Montreal buildings.


The AirGreen approach: precision and local adaptation

At AirGreen , we know that no two Montreal homes are truly alike. In this Rosemont project:

  • We adapted the installation to the constraints of the stone basement .

  • optimize existing conduits rather than imposing unnecessary modifications,

  • ensured a clean and sustainable integration , in accordance with best HVAC practices.

Our goal remains the same: to deliver a system that performs well today, but is also reliable for the next 15 to 20 years.


Four-season comfort, without compromise

Thanks to this Lennox central heat pump , the occupants now benefit from:

  • efficient and stable heating in winter,

  • uniform air conditioning during heat waves,

  • improved humidity control,

  • of superior acoustic comfort.

This is exactly the type of solution we regularly recommend in Rosemont–La Petite-Patrie and similar neighborhoods in Montreal.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment