Installation of a MIDEA EVOX G3 3-ton central heat pump in Boisbriand on the North Shore
Installation of a MIDEA EVOX G3 3-ton central heat pump in Boisbriand on the North Shore
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

A Strategic HVAC Installation to Combat Boisbriand's Harsh Winters

At AirGreen, we recently completed a comprehensive HVAC installation in Boisbriand, on the North Shore, featuring a MIDEA EVOX G3 3-ton (36,000 BTU) central heat pump. This project perfectly illustrates our approach: rigorous technical execution, a deep understanding of customer needs, and equipment selection tailored to Quebec's climatic realities.

The client, owner of a single-family home built in the 2000s, wanted to replace an old, inefficient, energy-consuming, and noisy central system. The objective was clear: improve thermal comfort, reduce energy costs, and benefit from available subsidies, notably the LogisVert program.

A Central System Designed for Cold Climate Performance

Technical Specifications of the Installed MIDEA EVOX G3

The MIDEA EVOX G3 | 3-ton central heat pump we installed stands out for its specifications particularly suited to the climate of Montreal, Laval, and the North Shore:

  • Cooling Capacity: 36,000 BTU
  • Heating Capacity down to -30°C
  • SEER2: 17.7
  • HSPF2: 10.0
  • EER2: 12.0
  • ENERGY STAR® Certification (Cold Climate)
  • Eco-friendly R-454B Refrigerant
  • Integrated WiFi
  • Voltage: 220V
  • Piping: 3/8 – 3/4
  • AHRI: 215471343

This model is renowned for its thermal stability, even during periods of intense cold. Unlike some systems that lose efficiency below -20°C, the EVOX G3 maintains consistent performance, reducing the need for auxiliary heating.

A Significant Subsidy Not to Be Overlooked

For this project in Boisbriand, the client was able to benefit from a LogisVert subsidy of $3,720, which significantly improved the return on investment. At AirGreen, we systematically assist our clients in the steps to maximize these financial aids.

Technical Challenges Encountered During Installation

Restricted Access and Complex Duct Configuration

One of the main challenges of this installation concerned access to the existing central system. The indoor unit had to be installed in a relatively narrow mechanical space, with ducts already in place but requiring adjustments.

We had to:

  • Adapt connections without compromising airflow
  • Optimize duct alignment to avoid pressure losses
  • Install anti-vibration supports to reduce noise

Thanks to our expertise in central heat pump installation, we were able to turn this constraint into an advantage by improving overall air circulation in the house.

Refrigerant Line Management and Outdoor Protection

As seen in the project image, the outdoor unit was installed with meticulous attention to detail:

  • Complete insulation of refrigerant lines
  • Mechanical protection with robust casing
  • Installation of a standard-compliant electrical disconnect
  • Strategic positioning to minimize noise and maximize efficiency

We also performed a complete vacuum pull with micron test, ensuring the total absence of moisture in the system — a crucial step often overlooked by less rigorous installers.

Why This Choice Was Optimal for This Client

An Intelligent Replacement of an Aging System

The previous system was still functional, but at a very low efficiency. The client observed:

  • High electricity bills
  • Uneven heat distribution
  • Excessive noise

With the MIDEA EVOX G3, these problems were eliminated from the first days of use.

Inverter Technology for Constant Comfort

Inverter technology allows real-time adjustment of compressor power. The result:

  • Stable temperature
  • Fewer on/off cycles
  • Reduced energy consumption

In this Boisbriand home, this translated into a much more uniform sense of comfort, without unpleasant fluctuations.

Client Feedback After Installation

A few weeks after commissioning, the client shared their experience with us:

  • Immediately improved comfort
  • Remarkable quietness of the outdoor unit
  • Easy control via the WiFi application
  • Significant reduction in energy consumption

This type of feedback is common with the MIDEA EVOX G3 heat pump, which we have already installed multiple times in Laval, Longueuil, and Montreal.

Best Practices and Tips for a Successful Installation

What We Always Recommend

To guarantee the longevity and performance of a system like this, we emphasize several essential points:

  • Always perform an accurate sizing (load calculation)
  • Never neglect vacuum pulling and pressure tests
  • Ensure good duct insulation
  • Install high-performance filters (MERV 13 recommended)

Mistakes to Avoid

  • Installing an oversized or undersized heat pump
  • Reusing old ducts without inspection
  • Neglecting annual maintenance

At AirGreen, every HVAC installation in Montreal, Laval, or on the North Shore is carried out according to strict, uncompromising standards.

A Sustainable Solution for Quebec Homes

The MIDEA EVOX G3 central heat pump represents a wise choice for homeowners wishing to:

  • Reduce their carbon footprint
  • Benefit from a reliable long-term system
  • Take advantage of government subsidies
  • Improve their comfort in summer and winter

In a context where energy costs are rising, investing in a high-performance system becomes a strategic decision.

AirGreen's Expertise: More Than Just an Installation

This project in Boisbriand reflects our commitment to offer:

  • A free and accurate evaluation
  • A professional, uncompromising installation
  • Responsive after-sales service
  • Complete price transparency

Our teams operate throughout Montreal, Laval, Longueuil, the North Shore, and the South Shore, with recognized expertise in central heat pumps.

Conclusion: An Installation That Makes a Difference

The installation of this MIDEA EVOX G3 central heat pump in Boisbriand demonstrates that a well-executed project can completely transform the comfort of a home. Thanks to advanced technology, rigorous installation, and comprehensive support, the client now benefits from a reliable, high-performance, and economical system.

At AirGreen, we continue to raise the standards of HVAC installation in Quebec, one project at a time.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

    1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
    2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
    3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
    4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
    5. The outdoor unitOn a level base, raised above the snow, with free space all around.
    6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
    7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
    8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
    9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: central heat pump, indoor module and ducts

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

    2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

    3. A shut-off switch near the outdoor unit isolates it safely for service.

    4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

    5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

    6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

    7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

    8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment